English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Dapekkan Kutipan Instan
Leave Your Message
Lai barani awak mailak dari grounding hanyo jo mamasang penghalang keselamatan? Kaduonyo ko indak pernah jadi pertanyaan pertanyaan pilihan Tunggal!
Barito

Lai barani awak mailak dari grounding hanyo jo mamasang penghalang keselamatan? Kaduonyo ko indak pernah jadi pertanyaan pertanyaan pilihan Tunggal!

13 Mei 2025

"Bisakah Kabel Kontrol di Ruang Lemari Tatap Indak Dibumikan jo Panghalang Kaamanan? Ado nan picayo baso "jo pambateh kaamanan untuak palinduangan lonjakan jo isolasi gangguan, pambumian lapisan pelindung kabel kontrol dapek dilakukan sacaro santai." Namun, standar nan relevan jaleh manyatokan persyaratan jo metode pembumian lemari untuak pambumian kabinet dalam pembumian. Apokah grounding lapisan pelindung kabel kontrol di sisi dalam ruang lemari takaik jo adonyo penghalang keselamatan?Hari ko, kami jalehkan sagalonyo tantang pembumian lapisan pelindung kabel kontrol di ruang lemari.”

Pembumian lapisan pelindung kabel kontrol di ruang lemari .tarutamo bafungsi untuak manantang gangguan, jo fungsi jo tujuan khusus barikuik:

1.Mancagah gangguan elektromagnetik lua: Sasudah dibumikan, lapisan palinduang batindak sarupo "pambateh," mangarahkan arus nan diinduksi dek medan elektromagnetik lua ka dalam bumi, sahinggo mancegah sinyal gangguan masuak ka dalam kabel jo mampangaruahi akurasi sinyal kontrol nan ditransmisikan.

2.Mancagah sinyal internal dari mangganggu parangkat lua: Sinyal nan ditransmisikan dalam kabel dapek mahasilkan medan elektromagnetik. Lapisan palinduang nan dibumikan dapek manakan ladang-ladang ko dari manyebar ka lua, mahindari gangguan jo paralatan sakitarnyo.

3.Malinduangi paralatan jo kasalamatan personil: Jikok lapisan palinduang indak dibumikan, panumpuakan statis atau tegangan nan indak normal dapek manyababkan gangguan bafungsi paralatan. Grounding mangaliahkan muatan balabiah ka dalam bumi, mangurangi resiko kaamanan.

Persyaratan standar kunci jo praktek untuak mambumikan lapisan pelindung kabel kontrol di ruang lemari:

1.GB 50093-2013 "Kode untuak Pambangunan jo Panarimoan Mutu Rekayasa Instrumentasi Otomasi

10.2.10 Lapisan pelindung kabel jo kawat instrumen harus dibumikan pado panel ruang kontrol/sisi lemari. Lapisan pelindung dari rangkaian nan samo harus mampunyoi kontinuitas listrik nan dapek diandalkan dan indak buliah dibiakan mangambang atau dibumikan baulang-ulang.

10.2.11 Baju basi kabel lapis baja harus dibumikan untuak palinduangan di kaduo ujuangnyo.

10.2.12 Pado kotak simpang antaro, lapisan pelindung kabel primer nan dibagi-bagi harus dihubuangkan jo lapisan pelindung kabel sekunder nan sasuai jo manggunoan terminal. Lapisan pelindung nan babeda harus dihubuangkan sacaro tapisah tanpa bacampua dan harus diisolasi.

10.2.13 Katiko ado persyaratan anti gangguan, inti cadangan pado kabel multi-inti harus dibumikan pado satu titiak. Untuak kabel nan dilindungi, inti cadangan jo lapisan pelindung harus dibumikan di sisi nan samo.

2.SH/T 3081-2019 "Kode Desain untuak Pembumian Alat di Industri Minyak Bumi jo Kimia".

LAMPIRAN A

(Lampiran Normatif)

Peta pembumian kabel nan dilindungi

Lapisan pelindung kabel utamo multi-inti pado divisi layar kasaluruahan taruih dihubuangkan ka ruang lemari sarupo nan ditunjukkan pado Gambar A-1. Lapisan pelindung kabel utamo multi-inti pado divisi layar kasaluruahan dibagi-bagi dan dihubuangkan ka kotak simpang jo ruang lemari sarupo nan ditunjukkan pado Gambar A-2. Lapisan pelindung kabel utamo multi-inti pado divisi layar kasaluruahan taruih dihubuangkan ka ruang lemari sarupo nan ditunjukkan pado Gambar A-3. Lapisan pelindung kabel utamo multi-inti pado divisi layar kasaluruahan dibagi-bagi dan dihubuangkan ka kotak simpang jo ruang lemari sarupo nan ditunjukkan pado Gambar A-4.


6

Instruksi kabel untuak lapisan pelindung pado Gambar A-1 sampai A-4 ditunjuakan pado Tabel A. Kabel cabang dari instrumen lapangan ka kotak simpang adolah kabel pelindung tungga atau kabel pelindung lapis baja tungga. Kabel lapis baja nan masuak ka kotak simpang manggunoan sambungan kabel jo sambungan grounding untuak mamudahkan sambungan grounding. Lapisan pelindung satiok kabel cabang di Lampiran Gambar A-2 sampai A-4 harus dihubuangkan basamo-samo di kotak simpang manggunokan terminal atau busbar.

Lapisan pelindung kabel cabang jo kabel utamo dapek dihubuangkan jo dibumikan pado lemari ruang kontrol, atau tapisah pado kotak simpang jo lemari ruang kontrol nan mambumikan bagian.

Lapisan pelindung kabel cabang pado Gambar A-1 dihubuangkan jo lapisan pelindung dalam kabel utamo, dan lapisan pelindung kabel cabang pado Gambar A-3 dihubuangkan jo lapisan pelindung kabel utamo pado kotak simpang. Lapisan pelindung nan tasambuang sapanuahnyo dibumikan pado lemari ruang kontrol pado salah satu ujuangnyo.

Lapisan pelindung kabel cabang pado Gambar A-2 jo A-4 dibumikan pado satu ujuang di kotak simpang, sadangkan lapisan pelindung dalam kabel utamo pado Gambar A-2 jo lapisan pelindung kabel utamo pado Gambar A-4 dibumikan pado satu ujuang di lemari ruang kontrol.

Lapisan baju zirah kabel utamo dibumikan pado kaduo ujuangnyo manuruik Pasal 4.4.1, dan baki kabel logam dibumikan pado kaduo ujuangnyo manuruik Pasal 4.1.8, jo dibumikan baulang satiok 30m.


Tabel A Metode Kabel untuak Lapisan Pelindung .

Metode sambungan pelindung

Kotak simpang

Kabinet

Kabel cabang dari instrumen di tampek sampai ka kotak simpang

Kabel utamo multi inti untuak layar total jo layar pacah

Angka A-1.

Lapisan pelindung dihubuangkan ka kabel utamo malalui terminal dan indak dibumikan .

Lapisan baju besi atau tabuang palinduang logam dihubuangkan ka busbar pembumian untuak palinduangan .

Lapisan pelindung dihubuangkan jo lapisan pelindung kabel cabang malalui terminal dan indak dibumikan .

Lapisan pelindung total dihubuangkan ka tanah palinduang malalui busbar pembumian .

Lapisan pelindung dihubuangkan ka tampek karajo malalui busbar pembumian .

Lapisan pelindung total dihubuangkan ka tanah palinduang malalui busbar pembumian .

Gambar A-2.

Lapisan pelindung dihubuangkan jo tanah palinduang malalui busbar pembumian .

Lapisan baju besi atau tabuang palinduang logam dihubuangkan ka busbar pembumian untuak palinduangan .

Lapisan pelindung nan kosong

Lapisan pelindung total dihubuangkan ka tanah palinduang malalui busbar pembumian .

Lapisan pelindung dihubuangkan ka tampek karajo malalui busbar pembumian .

Lapisan pelindung total dihubuangkan ka tanah palinduang malalui busbar pembumian .

 

Kotak simpang

Kabinet

Kabel cabang dari instrumen di tampek sampai ka kotak simpang

Kabel utamo multi inti untuak layar total jo layar pacah

Gambar A-3.

Lapisan pelindung dihubuangkan jo lapisan pelindung kabel utamo sacaro kasaluruahan malalui terminal dan indak dibumikan

Lapisan baju besi atau tabuang palinduang logam dihubuangkan ka busbar pembumian untuak palinduangan .

Indak ado lapisan pelindung tapisah

Lapisan pelindung total dihubuangkan jo lapisan pelindung kabel cabang malalui terminal dan indak dibumikan .

Indak ado lapisan pelindung tapisah

Lapisan pelindung total dihubuangkan ka tampek karajo malalui busbar pembumian .

Gambar A-4.

Lapisan pelindung dihubuangkan jo tanah palinduang malalui busbar pembumian .

Lapisan baju besi atau tabuang palinduang logam dihubuangkan ka busbar pembumian untuak palinduangan .

Indak ado lapisan pelindung tapisah

Lapisan pelindung sacaro kasaluruahan kosong

Indak ado lapisan manetek layar pacah

Lapisan pelindung total dihubuangkan ka tampek karajo malalui busbar pembumian .

Aplikasi praktis rekayasa jo gambar kahidupan nyato di tampek:

6Gambar kami maota

Pembumian lapisan pelindung di sisi dalam kabel kontrol di ruang lemari indak takaik jo apokah penghalang keselamatan (Panghalang Isolasis, pelindung gelombang, dll) dikonfigurasikan. Kacuali ado persyaratan khusus dalam dokumen desain, inyo harus dilaksanakan sacaro ketat sasuai jo spesifikasi.

Gambar Ota Kami