PHD-11TT-88
Overview
Isolated safety barrier at detection side: PHD-11TT-88, thermocouple signal input, single input and single output.
The isolated safety barrier can realize the transmission of thermocouple signals (-5-60mV) from dangerous areas in proportion 1:1 to the safe area, and thermocouples can be K, S, E, J, B, T, R, N types.
When ordering, please indicate the specific parameters
*Bus terminal power supply, please see appendix for details.
| Specifications | |
| Supply voltage | 20~35VDC, power consumption<0.8W |
| Input signal | K, S, E, J, B, T, R, N, TC Signals |
| Output signal | TC 1:1 |
| Signal and measurement range | Signal range: corresponding to the measuring range of TC -5~60mV |
| Measurement range: When make an order, the user shall make the configuration by himself, which shall be indicated in the tail number or extra explained. | |
| Channel number of input and output | 1 input 1 output |
| Output accuracy | 0.1%F.S (Typical value: 0.05%F.S) |
| Temperature drift | 0.005%F.S/℃ |
| Temperature parameters | Working temperature: -20℃~+60℃, storage temperature:-40℃~+80℃ |
| Relative humidity | 10%~95% RH no condensation |
| Dielectric strength | Between intrinsically safe side and non-intrinsically safe side (≥ 3000VAC/min); between power supply and non-intrinsically safe terminal (≥ 1500VAC/min) |
| Insulation resistance | ≥100MΩ (between input/output/power supply) |
| External dimensions | Thickness 12.5mm x width 108mm x high 118mm |
| Electromagnetic compatibility | According to IEC 61326-1(GB/T 18268), IEC 61326-3-1 |
| Explosion-proof mark | [Exia Ga]IIC |
| Certification Body | CQST(China National Quality Supervision and Test Centre for Explosion Protected Electrical Products) |
| Certified parameters (between terminals 3-4) |
Um:250V AC/DC Uo=8.4V DC Io=31mA Po=65.1mW Co=4.8μF Lo=20mH |
| Installation site Requirements | It can be connected with instruments in 0 zone with ⅡA, ⅡB, ⅡC dangerous gas |
| MTBF | ≤100000h |



PHD-11TC-33A-23