01
PHD-22HT-*1*1
Overview
Isolated safety barrier at detection side: PHD-22HT-*1*1, thermocouple signal input, dual input and dual output.The safety barrier can realize the conversion of thermocouple signal input in dangerous area into 4~20mA signal output and transmit it to safe area. The circuit has two thermocouple inputs and two DC signal 4~20mA outputs.
The output 4~20mA signal can be intelligently configured, and the actual measuring range can be set by computer.
PHD-22HT-*1*1, "*" indicates the input type of thermocouple, please use code to indicate it. This product needs independent power supply.
Input signal types and measurement range |
||||
Code |
RTD model |
Measurement range |
Minimum range |
Conversion accuracy |
1 |
K |
-200~1370℃ |
50℃ |
0.5℃/0.1%S |
2 |
S |
-50~1760℃ |
500℃ |
1.5℃/0.1%E |
3 |
E |
-140~1000℃ |
50℃ |
0.5℃/0.1%s |
4 |
J |
-160~1200℃ |
50℃ |
0.5℃/0.1% |
5 |
B |
250~1800℃ |
500℃ |
1.5℃/0.1%R |
6 |
T |
200~4000℃ |
50℃ |
0.5℃/0.1% |
7 |
R |
-50~17600℃ |
500℃ |
1.5℃/0.1%R |
8 |
N |
-200~1300℃ |
50℃ |
0.5℃/0.1% |
Example: when the input are 2 inputs with
K-couple, temperature range is 0~1200℃, 2 outputs are 4~20mA, power supply 20~35VDC, then the model should be
PHD-22HT-1111 (0~1200℃).
The measuring range can be set to the specified 0~1200℃ range by computer
Supply voltage | 20~35VDC, power consumption<2W (when power supply 24VDC, output 20mA) |
Input signal | K, S, E, J, B, T, R, N, TC Signals |
Output signal | 4~20mA |
Signal and measurement range | Signal range: corresponding to the measuring range of TC -10~100mV |
Measurement range: When make an order, the user shall make the configuration by himself, which shall be indicated in the tail number or extra explained | |
Allowable output load capacity | 0~500Ω (customizable) |
Alarm indication | L1 light is on at low-measurement range alarm; L2 light is on at high-measurement range alarm |
Channel number of input and output | 2 inputs 2 outputs |
Applicable field devices | K, S, E, J, B, T, R, N TC sensors |
Output accuracy | 0.1%F.S (Typical value: 0.05%F.S) |
Cold junction compensation | ±1℃ (Compensation range -20℃-+60℃) |
Temperature drift | 0.005%F.S/℃ |
Temperature parameters Working temperature: | -20℃~+60℃, storage temperature: -40℃~+80℃ |
Relative humidity | 10%~95% RH no condensation |
Insulation strength | Between intrinsically safe side and non-intrinsically safe side (≥3000VAC/min); |
between power supply and non-intrinsically safe side (≥1500VAC/min) | |
Insulation resistance | ≥100MΩ (between input/output/power supply) |
External dimensions | Thickness 15.8mm * width 104.8mm * high 116.1mm |
Electromagnetic compatibility | According to IEC 61326-1 (GB/T 18268), IEC 61326-3-1 |
Relative humidity | 10%~95% RH no condensation |
Explosion-proof mark | [Exia Ga]IIC |
Certification body | CQST (China National Quality Supervision and Test Centre for Explosion Protected Electrical Products) |
Certified parameters(between terminals 4-5-6, 1-2-3) | Um=250V Uo=8.4V Io=31mA Co=4.8μF Lo=20mH Po=65mW |
Installation site requirements | It can be connected with instruments in 0 zone with ⅡA, ⅡB, ⅡC dangerous gas |
MTBF | ≤100000h |
PHD-11TC-33A-23
PHD-22HT-X1X1