English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Get Instant Quote
Leave Your Message
PHC-11TF-14
Digital Output
Products Categories
Featured Products

PHC-11TF-14

PHC-11TF-14      1 input 1 output

Input: Switch contacts, logic levels
Output: 12V/45mA driver

    Overview

    The switching output isolated safety barrier drives the on-site intrinsically safe equipment in the hazardous area through the contact switch and logic level signal control in the safe area. Thereby controlling solenoid valves, sound and light alarms, etc. The signal status indicator light is set in red and yellow colors, the alarm displays red, and the output solenoid valve and other working tasks display yellow.

    This product needs to be powered independently, and the power supply, input and output terminals are isolated between each other.

     

    2

     

    Supply voltage
    20~35V DC,   Power consumption: ≤80mA(24V power supply,
    when 12V/45mA power distribution)
    Input signal Switch contact, logic level
    Output signal Open circuit voltage >24V, UE/IE=12.8V/45mA
    Inversion function: K1 is set to the "ON" side, the circuit output is inverted.
    Alarm relay function The dial switch K2 is set to the "ON" side, the circuit adopts the alarm function
    Load Resistance< 50Ω, short-circuit alarm (SC), load resistance >10KΩ, open circuit alarm (LB)
    Alarm relay output characteristics Response time: 20ms, driving capacity: 250VAC/2A, 30VDC/2A under resistive load
    Number of input and output channels 1 input 1 output
    Applicable onsite equipments Safety solenoid valve, audible and visual alarm
    Temperature parameters Working temperature: -20℃~+60℃, storage temperature:-40℃~+80℃
    Relative humidity 10%~95% RH no condensation
    Dielectric strength Between intrinsically safe side and non-intrinsically safe side (≥ 3000VAC/min); between power supply and non-intrinsically safe terminal (≥ 1500VAC/min)
    Insulation resistance ≥100MΩ (between input/output/power supply)
    External dimensions Thickness 12.5mm x width 108mm x high 118mm
    Electromagnetic compatibility According to IEC 61326-1(GB/T 18268), IEC 61326-3-1
    Explosion-proof mark [Ex ia Ga] IIC [Ex ia Da] ⅢC
    Certification Body CQST(China National Quality Supervision and Test Centre for Explosion Protected Electrical Products)
    Authentication parameters (between terminals 3-4) Um=250V  Uo=28V  Io=119mA  Co=0.05μF  Lo=2.1mH  Po=0.83W
    Installation site Requirements

    Installed in a safe zone, it can be connected to intrinsic safety instruments in hazardous areas up to Zone 0, IIC, Zone 20, and IIIC



    PHC-11TF-14

    Note: The power supply of the power rail is an optional function. Users need to specify the power supply mode when ordering.

    Please refer to attachment on page 89.

    3CCNEXFCC


    Download_file
    PHD-11TC-33A-23
    Download_file
    PHC-11TF-14