English
English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Get Instant Quote
Leave Your Message
PHG-11TT Series   PHG-12TT series
Temperature Signal Input
Products Categories
Featured Products

PHG-11TT Series PHG-12TT series

PHG-11TT series      1 input 1 output
PHG-12TT series     1 input 2 outputs

Input: TC signal
Output: DC signal (current/voltage)

    Overview

    Thermocouple input temperature transmitter can isolate and convert the DC signal from the thermocouple (TC) into a DC signal. This product has a built-in cold junction compensation function and can be configured intelligently. The actual range of the thermocouple can be set through computer software. . It has the function of disconnection alarm and out-of-range alarm function. This product needs to be powered independently, and the power supply, input and output terminals are isolated.

    Parameters Definition

    Code

    TC  model

    Measurement range

    Minimum range

    Conversion accuracy

    1

    K

    -200~1370℃

    50℃

    0.5℃/0.1%

    2

    S

    -50~1760℃

    500℃

    1.5℃/0.1%

    3

    E

    -140~ 1000℃

    50℃

    0.5℃/0.1%

    4

    J

    -160~1200℃

    50℃

    0.5℃/0.1%

    5

    B

    250~1800℃

    500℃

    1.5℃/0.1%

    6

    T

    -200~400℃

    50℃

    0.5℃/0.1%

    7

    R

    -50~1760℃

    500℃

    1.5℃/0.1%

    8

    N

    -200~1300℃

    50℃

    0.5℃/0.1%

     

    1

     

    Input
    Input signal
    K, S, E, J, B, T, R, N TC signals (see "Input Signal Type and Range Table" for details)
    Input disconnection The default "low alarm" can be modified to "high alarm" through configuration software
    Signal range The measuring range of the corresponding thermocouple is -10~100mV.
    Measurement range Users make their own configuration when ordering, and indicate it at the tail number or otherwise.
    Built-in cold compensation ±1°C(Compensation range -20°C~ +60°C)
    Output:
    Output signal DC signal (current/voltage)
    Load Resistance Current load resistance ≤500Ω (customizable)
    Voltage load resistance <5mA (customizable)
    Supply voltage 20-35VDC
    Power consumption Current output <0.8W; voltage output <0.6W (PHG-11TT series) Current output <1.2W; voltage output <0.6W (PHG-12TT series)
    LED indicator Green: Power indicator Low range alarm L1 light on, high range alarm L2 light on
    Output accuracy Please refer to the "Input Signal Type and Range Table" for details
    Response time Reaching 90% of the final value within 300ms
    Temperature drift 0.005%F.S/℃
    Temperature parameters Working temperature: -20℃~+60℃, storage temperature:-40℃~+80℃
    Relative humidity 10%~95% RH no condensation
    Dielectric strength ≥2000VAC/min  (between input/output/power supply)
    Insulation resistance 100MΩ (500V DC)(between input/output/power supply)
    Electromagnetic compatibility GB/T 18268,IEC 61326-1
    MTBF 80000h
    Wire requirements Cross section ≥ 0.5mm2; Insulation strength ≥ 500V
    Applicable field equipments K. S, E, J, B, T, R, N TC sensors



    1

    Note: 1. PHG-11TT does not include output part 2
    2. The power rail function is an optional function, and users need to specify
    the power supply method when placing an order
    The selection of power rail connectors can refer to page 89 of the "Annex"

    1

    For example: one input and one output, thermocouple K (-200-1370℃) input, 4-20mA output,
    24V power supply: Model: PHG-11TT-11



    Download_file
    PHD-11TC-33A-23


    Download_file
    PHG-11TT series PHG-12TT series