- Isolated Safety Barriers
- Signal Isolators
- Surge Protective Devices
- Safety Relays
- Isolated Intelligent I/O Modules
- Intelligent Gateways
- Industrial Data Optical Transceivers
- Online Dew Point Analyzers
- Data Acquisition Modules
- HART data converter
- Terminal Board
- Safety Interlock Switches
- Safety Light Curtains
- Temperature transmitter
PHLR Series Safety Interlock Switch
PHLR Series introduction
Safety interlock switch is a safety device used to lock and monitor the movable mechanisms such as safety fence doors, and protective covers. The
strong structural design of SLR11 series make it withstand higher tension. The RFID technology has higher security and confidentiality. Sensor &
actuator support universal and unique coding. Small size for easy installation.
Product features
- With locking & monitoring function;
- Optional coding modes: universal coding &unique coding;
- Self-diagnose &cross-diagnose: periodic double cross-diagnose improves security;
- Independent redundant dual signal: in case of hazard caused by signal loop failure;
- Small size: 29.7mm* 29.7mm section size;
- Flexible installation: directly installed on aluminum frame less than 30mm, brackets is no need.
Product Parameters
|
Standard |
EN ISO 13849-1(Category 4/PL e);EN ISO 14119; EN IEC 60947-5-2;EN IEC 60947-5-3 |
|
|
Certification |
CE |
|
|
Lock mode |
Mechanical/electromagnetic |
|
|
Response time |
Lock→unlock |
<250ms |
|
Unlock→lock |
<300ms |
|
|
Lock |
Lock retentivity Fzh |
≥2000N |
|
Lock bolt insertion deviation |
≤2mm |
|
|
Mechanical endurance |
>100 million times(door operating speed 1m/s) |
|
|
Operation frequency |
1Hz |
|
|
Minimum radius of the revolving door |
≥250mm |
|
|
Manual unlock |
Front, back |
|
|
Safe output OSSD output |
Output signal |
NPN*2/PNP*2 |
|
Max. load current |
≤200mA |
|
|
Residual voltage when it's ON |
<2.5V(cable 5m) |
|
|
Voltage when it's OFF |
≤2V(cable 5m) |
|
|
Leakage current |
≤0.5mA |
|
|
Max. load capacity |
2uF |
|
|
Load connection resistance |
≤2.5Ω |
|
|
Auxiliary output AUX output |
Output signal |
NPN*1/PNP*1 |
|
Max. load current |
50mA |
|
|
Residual voltage when it's ON |
≤2.5V@50mA |
|
|
External input breakage current |
Safe input |
5mA*2 |
|
Reset/EDM input |
About 10mA*1 |
|
|
Lock control input |
About 10mA*1 |
|
|
Power supply |
Working voltage |
DC24V±20% |
|
Power consumption |
3.6W*1 |
|
|
Protection |
Power supply reverse polarity, output short circuit, output reverse polarity protection |
|
|
Environment |
Enclosure protection class |
IP65 |
|
Working temperature |
-20~55℃(no freezing) |
|
|
Storage temperature |
-25~70℃(no freezing) |
|
|
Working humidity |
5%~95%RH |
|
|
Storage humidity |
5%~95%RH |
|
|
Vibration resistance |
10-55Hz, double amplitude 2.0mm, 5 minutes each in X, Y and Z directions |
|
|
Shock resistance |
30G, 6 times each in X, Y and Z directions (IEC 60947-5-3) |
|
|
|
Cascade connection |
Up to 20 units |
|
Start time |
1.5s |
|
|
Material |
Nylon/zinc alloy/stainless steel |
|
*1: Power consumption and load current is excluded. The moment the lock control input is activated, the power consumption will temporarily increase
(up to 15W, approximately 50ms).
Model Selection (ex: PHLR-□□□□□-□□)

|
Function of Standard Mode & Advanced Mode |
||||||
|
|
Safe output channel |
AUX output channel |
Safe input channel |
Lock input channel |
EDM |
Reset |
|
Standard mode |
• |
• |
• |
• |
— |
— |
|
Advanced mode |
• |
• |
• |
• |
• |
• |
AUX Function Selection
No: AUX output is monitored by door lock (reverse)
|
Door state
|
Lock state
|
OSSD output
|
AUX output
|
|
Open
|
Non-locking
|
OFF
|
ON
|
|
Close
|
Non-locking
|
OFF
|
ON
|
|
Close
|
Locking
|
ON
|
OFF
|
A: AUX output is monitored by key (reverse)
|
Door state
|
Lock state
|
OSSD output
|
AUX output
|
|
Open
|
Non-locking
|
OFF
|
ON
|
|
Close
|
Non-locking
|
OFF
|
OFF
|
|
Close
|
Locking
|
ON
|
OFF
|
B: AUX output is monitored by key (front)
|
Door state
|
Lock state
|
OSSD output
|
AUX output
|
|
Open
|
Non-locking
|
OFF
|
OFF
|
|
Close
|
Non-locking
|
OFF
|
ON
|
|
Close
|
Locking
|
ON
|
ON
|
D: AUX output is monitored by door lock (front)
|
Door state
|
Lock state
|
OSSD output
|
AUX output
|
|
Open
|
Non-locking
|
OFF
|
OFF
|
|
Close
|
Non-locking
|
OFF
|
OFF
|
|
Close
|
Locking
|
ON
|
ON
|
PHSF Series Selection Tabel
|
Lock mode |
Configuration |
Output type |
Code type |
Model |
|
Electromagnetic |
Standard |
NPN |
Universal |
PHLR-000N |
|
NPN |
Unique |
PHLR-001N |
||
|
PNP |
Universal |
PHLR-000P |
||
|
PNP |
Unique |
PHLR-001P |
||
|
Advanced |
NPN |
Universal |
PHLR-010N |
|
|
NPN |
Unique |
PHLR-011N |
||
|
PNP |
Universal |
PHLR-010P |
||
|
PNP |
Unique |
PHLR-011P |
||
|
Mechanical |
Standard |
NPN |
Universal |
PHLR-100N |
|
NPN |
Unique |
PHLR-101N |
||
|
PNP |
Universal |
PHLR-100P |
||
|
PNP |
Unique |
PHLR-101P |
||
|
Advanced |
NPN |
Universal |
PHLR-110N |
|
|
NPN |
Unique |
PHLR-111N |
||
|
PNP |
Universal |
PHLR-110P |
||
|
PNP |
Unique |
PHLR-111P |
Sequence Diagram

Light indicator
![]() |
Indicator |
Color |
Details |
|
Output |
Red, green |
OSSD output: green OSSD close: red OSSD error: red blink (2Hz) EDM error: red blink (1Hz) |
|
|
Locking |
Green |
Locking: steady on Lock error: 2Hz blink (solenoid error, optocoupler error) No RFID: 1Hz blink Attempt to lock: ON after double blinking Attempt to unlock: OFF after double blinking Releasing: OFF |
|
|
Input |
Orange |
Normal input: light on No input (waiting for input): OFF Wait for reset: 1Hz blink Safe input error: 2Hz blink |
|
|
Working state |
Green, red, orange |
OSSD with output: green light is steady on OSSD without output: red light is steady on Voltage error: orange light 1Hz blink Unique code not matched: red, green and orange blink |
Product Dimension

Bracket Selection

Montage Diagram
Direction of lock body and key



Connection wiring



Cable Selection

Cable Selection Table
|
Standard cable |
Type |
Length |
Model |
|
|
Standard mode |
3m |
PHLR-M12P8S3 |
|
5m |
PHLR-M12P8S5 |
||
|
10m |
PHLR-M12P8S10 |
||
|
Advanced mode |
3m |
PHLR-M12P10S3 |
|
|
5m |
PHLR-M12P10S5 |
||
|
10m |
PHLR-M12P10S10 |