Get Instant Quote
Leave Your Message
PHLR Series Safety Interlock Switch
Safety Interlock Switches
Products Categories
Featured Products

PHLR Series Safety Interlock Switch

PHLR Series

High Performance Safety Interlock Switch

    PHLR Series introduction

    Safety interlock switch is a safety device used to lock and monitor the movable mechanisms such as safety fence doors, and protective covers. The
    strong structural design of SLR11 series make it withstand higher tension. The RFID technology has higher security and confidentiality. Sensor &
    actuator support universal and unique coding. Small size for easy installation.

    Product features

    • With locking & monitoring function;
    • Optional coding modes: universal coding &unique coding;
    • Self-diagnose &cross-diagnose: periodic double cross-diagnose improves security;
    • Independent redundant dual signal: in case of hazard caused by signal loop failure;
    • Small size: 29.7mm* 29.7mm section size;
    • Flexible installation: directly installed on aluminum frame less than 30mm, brackets is no need.

    Product Parameters

    Standard

    EN ISO 13849-1(Category 4/PL e);EN ISO 14119; EN IEC 60947-5-2;EN IEC 60947-5-3

    Certification

    CE

    Lock mode

    Mechanical/electromagnetic

    Response time

    Lock→unlock

    <250ms

    Unlock→lock

    <300ms

     

     

     

     

     

    Lock

    Lock retentivity Fzh

    ≥2000N

    Lock bolt insertion deviation

    ≤2mm

    Mechanical endurance

    >100 million times(door operating speed 1m/s)

    Operation frequency

    1Hz

    Minimum radius of the

    revolving door

    ≥250mm

    Manual unlock

    Front, back

     

     

     

     

     

    Safe output OSSD output

    Output signal

    NPN*2/PNP*2

    Max. load current

    ≤200mA

    Residual voltage

    when it's ON

    <2.5V(cable 5m)

    Voltage when it's OFF

    ≤2V(cable 5m)

    Leakage current

    ≤0.5mA

    Max. load capacity

    2uF

    Load connection resistance

    ≤2.5Ω

     

    Auxiliary output

    AUX output

    Output signal

    NPN*1/PNP*1

    Max. load current

    50mA

    Residual voltage when it's ON

    ≤2.5V@50mA

     

    External input

    breakage current

    Safe input

    5mA*2

    Reset/EDM input

    About 10mA*1

    Lock control input

    About 10mA*1

     

    Power supply

    Working voltage

    DC24V±20%

    Power consumption

    3.6W*1

    Protection

    Power supply reverse polarity, output short circuit, output reverse polarity protection

     

    Environment

    Enclosure protection class

    IP65

    Working temperature

    -20~55℃(no freezing)

    Storage temperature

    -25~70℃(no freezing)

    Working humidity

    5%~95%RH

    Storage humidity

    5%~95%RH

    Vibration resistance

    10-55Hz, double amplitude 2.0mm, 5 minutes each in X, Y and Z directions

    Shock resistance

    30G, 6 times each in X, Y and Z directions (IEC 60947-5-3)

     

    Cascade connection

    Up to 20 units

    Start time

    1.5s

    Material

    Nylon/zinc alloy/stainless steel

    *1: Power consumption and load current is excluded. The moment the lock control input is activated, the power consumption will temporarily increase
    (up to 15W, approximately 50ms).

    Model Selection (ex: PHLR-□□□□□-□□)

    Model Selection.png

    Function of Standard Mode & Advanced Mode

     

    Safe output channel

    AUX output channel

    Safe input channel

    Lock input channel

    EDM

    Reset

    Standard mode

    •

     •

    • 

     •

    —

    —

    Advanced mode

    • 

     •

     •

     •

     •

    •

    AUX Function Selection

    No: AUX output is monitored by door lock (reverse)

    Door state
    Lock state
    OSSD output
    AUX output
    Open
    Non-locking
    OFF
    ON
    Close
    Non-locking
    OFF
    ON
    Close
    Locking
    ON
    OFF

    A: AUX output is monitored by key (reverse)

    Door state
    Lock state
    OSSD output
    AUX output
    Open
    Non-locking
    OFF
    ON
    Close
    Non-locking
    OFF
    OFF
    Close
    Locking
    ON
    OFF

    B: AUX output is monitored by key (front)

    Door state
    Lock state
    OSSD output
    AUX output
    Open
    Non-locking
    OFF
    OFF
    Close
    Non-locking
    OFF
    ON
    Close
    Locking
    ON
    ON

    D: AUX output is monitored by door lock (front)

    Door state
    Lock state
    OSSD output
    AUX output
    Open
    Non-locking
    OFF
    OFF
    Close
    Non-locking
    OFF
    OFF
    Close
    Locking
    ON
    ON

    PHSF Series Selection Tabel

      Lock mode

      Configuration

      Output type

      Code type

      Model

       

       

       

       

       

      Electromagnetic

       

       

      Standard

      NPN

      Universal

      PHLR-000N

      NPN

      Unique

      PHLR-001N

      PNP

      Universal

      PHLR-000P

      PNP

      Unique

      PHLR-001P

       

       

      Advanced

      NPN

      Universal

      PHLR-010N

      NPN

      Unique

      PHLR-011N

      PNP

      Universal

      PHLR-010P

      PNP

      Unique

      PHLR-011P

       

       

       

       

       

      Mechanical

       

       

      Standard

      NPN

      Universal

      PHLR-100N

      NPN

      Unique

      PHLR-101N

      PNP

      Universal

      PHLR-100P

      PNP

      Unique

      PHLR-101P

       

       

      Advanced

      NPN

      Universal

      PHLR-110N

      NPN

      Unique

      PHLR-111N

      PNP

      Universal

      PHLR-110P

      PNP

      Unique

      PHLR-111P

      Sequence Diagram

      Sequence Diagram.png

      Light indicator

      Indicator

      Color

      Details

       

       

      Output

       

       

      Red, green

      OSSD output: green OSSD close: red

      OSSD error: red blink (2Hz)

      EDM error: red blink (1Hz)

       

       

       

       

      Locking

       

       

       

       

      Green

      Locking: steady on

      Lock error: 2Hz blink (solenoid error, optocoupler error) No RFID: 1Hz blink

      Attempt to lock: ON after double blinking Attempt to unlock: OFF after double blinking

      Releasing: OFF

       

       

      Input

       

       

      Orange

      Normal input: light on

      No input (waiting for input): OFF Wait for reset: 1Hz blink

      Safe input error: 2Hz blink

       

       

       

       

      Working state

       

       

       

       

      Green, red, orange

       

      OSSD with output: green light is steady on OSSD without output: red light is steady on Voltage error: orange light 1Hz blink

      Unique code not matched: red, green and orange blink

      Product Dimension

      Product Dimension.png

      Bracket Selection

      Montage Diagram

      Direction of lock body and key

      Correct montage.png

      Correct montage-1.pngCorrect montage-2.png

      Connection wiring

      Connection wiring.pngConnection wiring-1.pngConnection wiring-2.png

      Cable Selection

      Cable Selection.png

      Cable Selection Table

      Standard cable

       

      Type

       

      Length

       

      Model

       

       

       

       

       

       

      Standard mode

      3m

      PHLR-M12P8S3

      5m

      PHLR-M12P8S5

      10m

      PHLR-M12P8S10

       

       

      Advanced mode

      3m

      PHLR-M12P10S3

      5m

      PHLR-M12P10S5

      10m

      PHLR-M12P10S10

      Note: If leading wire type, you have no need to refer cable selection table.

      Cable Selection table -1.png