- Isolated Safety Barriers
- Signal Isolators
- Surge Protective Devices
- Safety Relays
- Isolated Intelligent I/O Modules
- Intelligent Gateways
- Industrial Data Optical Transceivers
- Online Dew Point Analyzers
- Data Acquisition Modules
- HART data converter
- Terminal Board
- Safety Interlock Switches
- Safety Light Curtains
- Temperature transmitter
PHLM Series 4 Contacts Safety Door Switch
PHLM Series introduction
PHLM series is the most common door interlock technology. It uses a inserting key to detect the movement of the protective door. As the small and light weight size, various contact configurations, and locking functions, safety door locks are usually the lowest cost solution. The PHLM series safety door lock allows the switch head to rotate at a 90° angle four times. The key can be inserted into the switch at five different positions. The electromagnet can be selected to work when powered on or off, providing various different options for the working mode of the switch and the installation method on the protective door. It improves the flexibility of the switch and make it suitable for use on various doors.
Product features
- Multiple and optional contacts construction;
- Holding force 1300N;
- IP67 protection class;
- PA66 flame retardant material;
- Support general load and micro load.
Product Parameters
|
Electromagnetic tube |
||
|
Nominal working voltage |
DC24V |
|
|
Power consumption |
about 4.8W*¹ |
|
|
Current consumption |
about 200mA*² |
|
|
Insulation |
Class B (130°C) |
|
|
LED indicator |
||
|
Nominal working voltage |
DC24V |
|
|
Nominal current |
about 2mA |
|
|
Luminous color (LED) |
Green |
|
|
Safety level |
PL d ISO 13849-1 |
|
|
Certification |
CE, TÜV |
|
|
Standard |
EN 60947-5-1, GB/T 14048.5, EN ISO 14119, GB/T 18831, UL 508 |
|
|
Protection class |
IP67 |
|
|
Material |
PA66 flame retardant |
|
|
Mechanical lifespan |
Over 1.000.000 times |
|
|
Electrical lifespan |
Over 150.000 times (AC240V3A,resistive load) |
|
|
Using type |
AC-15 |
DC-13 |
|
Nominal working voltage (Ue) |
240V |
24V |
|
Nominal working current (le) |
3A |
2A |
|
Electrical parameters |
||
|
Contact resistance |
<200mΩ |
|
|
Nominal discharge current (Ith) |
10A |
|
|
Nominal insulation voltage (Ui) |
300V |
|
|
Anti electric shock level |
Class Ⅱ (double insulation) |
|
|
Pulse withstand voltage (EN 60947-5-1) |
2.5KV |
|
|
Insulation resistance |
>100MΩ |
|
|
Short circuit protection |
10A, 250V requires a quick break fuse |
|
|
Vibration resistance |
10~55HZ double amplitude 1.5mm |
|
|
Impact resistance |
Durability 1000m/s2 |
|
|
Conditional short circuit current |
100A(EN 60947-5-1) |
|
|
Contact distance |
2*2mm above |
|
|
Action characteristics |
||
|
Direct opening force |
>10mm |
|
|
Direct operating speed |
0.1~0.5m/s |
|
|
Allowed operation frequency |
Max. 30 times/min |
|
|
Holding force |
1300N |
|
|
Environment |
||
|
Operating environment |
3(EN 60947-5-1) |
|
|
Operating temperature |
-10~+60℃(no freezing) |
|
|
Operating humidity |
<95%RH |
|
*1 The maximum inrush power of the door switch does not exceed 15W, and the power consumption will then return to within 4.8W.
*2 The maximum inrush current of the door switch does not exceed 600mA, and the current consumption will then return to within 200mA.
Model Selection (ex: PHLM-APM-B)

Product Dimension

Note: include back unlock function.
PHLM Series Selection Table
|
No |
Plastic |
Electromagnetic DC24V Green LED |
Electromagnetic lock Mechanical release |
1NC/1NO+1NC/1NO |
M20*1.5 |
PHLM-APE |
|
1NC/1NO+2NC |
M20*1.5 |
PHLM-BPE |
||||
|
2NC+1NC/1NO |
M20*1.5 |
PHLM-CPE |
||||
|
2NC+2NC |
M20*1.5 |
PHLM-DPE |
||||
|
1NC/2NO+1NC |
M20*1.5 |
PHLM-EPE |
||||
|
3NC+1NC |
M20*1.5 |
PHLM-FPE |
||||
|
2NC/1NO+1NC |
M20*1.5 |
PHLM-GPE |
||||
|
1NC+3NC |
M20*1.5 |
PHLM-HPE |
||||
|
1NC+1NC/2NO |
M20*1.5 |
PHLM-IPE |
||||
|
1NC+2NC/1NO |
M20*1.5 |
PHLM-JPE |
||||
|
1NO+3NC |
M20*1.5 |
PHLM-KPE |
||||
|
1NO+2NC/1NO |
M20*1.5 |
PHLM-LPE |
||||
|
1NC+1NC |
M20*1.5 |
PHLM-MPE |
||||
|
1NO+1NC |
M20*1.5 |
PHLM-NPE |
||||
|
Mechanical lock Electromagnetic release |
1NC/1NO+1NC/1NO |
M20*1.5 |
PHLM-APM |
|||
|
1NC/1NO+2NC |
M20*1.5 |
PHLM-BPM |
||||
|
2NC+1NC/1NO |
M20*1.5 |
PHLM-CPM |
||||
|
2NC+2NC |
M20*1.5 |
PHLM-DPM |
||||
|
1NC/2NO+1NC |
M20*1.5 |
PHLM-EPM |
||||
|
3NC+1NC |
M20*1.5 |
PHLM-FPM |
||||
|
2NC/1NO+1NC |
M20*1.5 |
PHLM-GPM |
||||
|
1NC+3NC |
M20*1.5 |
PHLM-HPM |
||||
|
1NC+1NC/2NO |
M20*1.5 |
PHLM-IPM |
||||
|
1NC+2NC/1NO |
M20*1.5 |
PHLM-JPM |
||||
|
1NO+3NC |
M20*1.5 |
PHLM-KPM |
||||
|
1NO+2NC/1NO |
M20*1.5 |
PHLM-LPM |
||||
|
1NC+1NC |
M20*1.5 |
PHLM-MPM |
||||
|
1NO+1NC |
M20*1.5 |
PHLM-NPM |
|
Yes |
Plastic |
Electromagnetic DC24V Green LED |
Electromagnetic lock Mechanical release |
1NC/1NO+1NC/1NO |
M20*1.5 |
PHLM-APE-B |
|
1NC/1NO+2NC |
M20*1.5 |
PHLM-BPE-B |
||||
|
2NC+1NC/1NO |
M20*1.5 |
PHLM-CPE-B |
||||
|
2NC+2NC |
M20*1.5 |
PHLM-DPE-B |
||||
|
1NC/2NO+1NC |
M20*1.5 |
PHLM-EPE-B |
||||
|
3NC+1NC |
M20*1.5 |
PHLM-FPE-B |
||||
|
2NC/1NO+1NC |
M20*1.5 |
PHLM-GPE-B |
||||
|
1NC+3NC |
M20*1.5 |
PHLM-HPE-B |
||||
|
1NC+1NC/2NO |
M20*1.5 |
PHLM-IPE-B |
||||
|
1NC+2NC/1NO |
M20*1.5 |
PHLM-JPE-B |
||||
|
1NO+3NC |
M20*1.5 |
PHLM-KPE-B |
||||
|
1NO+2NC/1NO |
M20*1.5 |
PHLM-LPE-B |
||||
|
1NC+1NC |
M20*1.5 |
PHLM-MPE-B |
||||
|
1NO+1NC |
M20*1.5 |
PHLM-NPE-B |
||||
|
Mechanical lock Electromagnetic release |
1NC/1NO+1NC/1NO |
M20*1.5 |
PHLM-APM-B |
|||
|
1NC/1NO+2NC |
M20*1.5 |
PHLM-BPM-B |
||||
|
2NC+1NC/1NO |
M20*1.5 |
PHLM-CPM-B |
||||
|
2NC+2NC |
M20*1.5 |
PHLM-DPM-B |
||||
|
1NC/2NO+1NC |
M20*1.5 |
PHLM-EPM-B |
||||
|
3NC+1NC |
M20*1.5 |
PHLM-FPM-B |
||||
|
2NC/1NO+1NC |
M20*1.5 |
PHLM-GPM-B |
||||
|
1NC+3NC |
M20*1.5 |
PHLM-HPM-B |
||||
|
1NC+1NC/2NO |
M20*1.5 |
PHLM-IPM-B |
||||
|
1NC+2NC/1NO |
M20*1.5 |
PHLM-JPM-B |
||||
|
1NO+3NC |
M20*1.5 |
PHLM-KPM-B |
||||
|
1NO+2NC/1NO |
M20*1.5 |
PHLM-LPM-B |
||||
|
1NC+1NC |
M20*1.5 |
PHLM-MPM-B |
||||
|
1NO+1NC |
M20*1.5 |
PHLM-NPM-B |
|
No |
Metal |
Electromagnetic DC24V Green LED |
Electromagnetic lock Mechanical release |
1NC/1NO+1NC/1NO |
M20*1.5 |
PHLM-AME |
|
1NC/1NO+2NC |
M20*1.5 |
PHLM-BME |
||||
|
2NC+1NC/1NO |
M20*1.5 |
PHLM-CME |
||||
|
2NC+2NC |
M20*1.5 |
PHLM-DME |
||||
|
1NC/2NO+1NC |
M20*1.5 |
PHLM-EME |
||||
|
3NC+1NC |
M20*1.5 |
PHLM-FME |
||||
|
2NC/1NO+1NC |
M20*1.5 |
PHLM-GME |
||||
|
1NC+3NC |
M20*1.5 |
PHLM-HME |
||||
|
1NC+1NC/2NO |
M20*1.5 |
PHLM-IME |
||||
|
1NC+2NC/1NO |
M20*1.5 |
PHLM-JME |
||||
|
1NO+3NC |
M20*1.5 |
PHLM-KME |
||||
|
1NO+2NC/1NO |
M20*1.5 |
PHLM-LME |
||||
|
1NC+1NC |
M20*1.5 |
PHLM-MME |
||||
|
1NO+1NC |
M20*1.5 |
PHLM-NME |
||||
|
Mechanical lock Electromagnetic release |
1NC/1NO+1NC/1NO |
M20*1.5 |
PHLM-AMM |
|||
|
1NC/1NO+2NC |
M20*1.5 |
PHLM-BMM |
||||
|
2NC+1NC/1NO |
M20*1.5 |
PHLM-CMM |
||||
|
2NC+2NC |
M20*1.5 |
PHLM-DMM |
||||
|
1NC/2NO+1NC |
M20*1.5 |
PHLM-EMM |
||||
|
3NC+1NC |
M20*1.5 |
PHLM-FMM |
||||
|
2NC/1NO+1NC |
M20*1.5 |
PHLM-GMM |
||||
|
1NC+3NC |
M20*1.5 |
PHLM-HMM |
||||
|
1NC+1NC/2NO |
M20*1.5 |
PHLM-IMM |
||||
|
1NC+2NC/1NO |
M20*1.5 |
PHLM-JMM |
||||
|
1NO+3NC |
M20*1.5 |
PHLM-KMM |
||||
|
1NO+2NC/1NO |
M20*1.5 |
PHLM-LMM |
||||
|
1NC+1NC |
M20*1.5 |
PHLM-MMM |
||||
|
1NO+1NC |
M20*1.5 |
PHLM-NMM |
|
Yes |
Metal |
Electromagnetic DC24V Green LED |
Electromagnetic lock Mechanical release |
1NC/1NO+1NC/1NO |
M20*1.5 |
PHLM-AME-B |
|
1NC/1NO+2NC |
M20*1.5 |
PHLM-BME-B |
||||
|
2NC+1NC/1NO |
M20*1.5 |
PHLM-CME-B |
||||
|
2NC+2NC |
M20*1.5 |
PHLM-DME-B |
||||
|
1NC/2NO+1NC |
M20*1.5 |
PHLM-EME-B |
||||
|
3NC+1NC |
M20*1.5 |
PHLM-FME-B |
||||
|
2NC/1NO+1NC |
M20*1.5 |
PHLM-GME-B |
||||
|
1NC+3NC |
M20*1.5 |
PHLM-HME-B |
||||
|
1NC+1NC/2NO |
M20*1.5 |
PHLM-IME-B |
||||
|
1NC+2NC/1NO |
M20*1.5 |
PHLM-JME-B |
||||
|
1NO+3NC |
M20*1.5 |
PHLM-KME-B |
||||
|
1NO+2NC/1NO |
M20*1.5 |
PHLM-LME-B |
||||
|
1NC+1NC |
M20*1.5 |
PHLM-MME-B |
||||
|
1NO+1NC |
M20*1.5 |
PHLM-NME-B |
||||
|
Mechanical lock Electromagnetic release |
1NC/1NO+1NC/1NO |
M20*1.5 |
PHLM-AMM-B |
|||
|
1NC/1NO+2NC |
M20*1.5 |
PHLM-BMM-B |
||||
|
2NC+1NC/1NO |
M20*1.5 |
PHLM-CMM-B |
||||
|
2NC+2NC |
M20*1.5 |
PHLM-DMM-B |
||||
|
1NC/2NO+1NC |
M20*1.5 |
PHLM-EMM-B |
||||
|
3NC+1NC |
M20*1.5 |
PHLM-FMM-B |
||||
|
2NC/1NO+1NC |
M20*1.5 |
PHLM-GMM-B |
||||
|
1NC+3NC |
M20*1.5 |
PHLM-HMM-B |
||||
|
1NC+1NC/2NO |
M20*1.5 |
PHLM-IMM-B |
||||
|
1NC+2NC/1NO |
M20*1.5 |
PHLM-JMM-B |
||||
|
1NO+3NC |
M20*1.5 |
PHLM-KMM-B |
||||
|
1NO+2NC/1NO |
M20*1.5 |
PHLM-LMM-B |
||||
|
1NC+1NC |
M20*1.5 |
PHLM-MMM-B |
||||
|
1NO+1NC |
M20*1.5 |
PHLM-NMM-B |
Contacts structure and action

Operation Key Model


Back unlock set

Note: For more types of back unlock unit, please refer to the back unlock unit selection guide.
Montage and Matching instruction
- Diagram of PHMB-M04 safety bolt with a rotating back unlock unit.

- Diagram of PHMB-M05 safety bolt with a press back unlock unit.

Product Montage