PHG-11TT+/ PHG-12TT+

Surge Protection Type Signal Isolators

Products Categories
Featured Products

PHG-11TT+/ PHG-12TT+

Surge protection type TC input temperature converter

PHG-11TT+  1 input 1 output
PHG-12TT+  1 input 2 outputs

Input :TC signal

Output :DC signal (current/voltage)

    Overview

    Thermocouple input temperature converter with surge protection function can isolate and convert thermocouple (TC) DC signals into current signals. This temperature converter has built-in cold end compensation and can be intelligently configured. The actual range of the thermocouple can be set through computer software. It has the functions of wire breakage alarm and out of range alarm.

    This product requires independent power supply, with isolated power supply, input, and output terminals.

    Specifications

    Input 
    Input signal K, S, E, J, B, T, R, N thermocouple signals (see "Input Signal Type and Range Table" for details)
    Input disconnection The default "low alarm" can be modified to "high alarm" through configuration software
    Signal range The measuring range of the corresponding thermocouple is -10~100mV.
    Measurement range Users make their own configuration when ordering, and indicate it at the tail number or otherwise.
    Built-in cold compensation ±1°C(Compensation range -20°C~ +60°C)
    Output:
    Output signal DC signal (current/voltage)
    Output load capacity Current load resistance ≤500Ω (can be customized)
    Voltage load resistance <5mA (can be customized)
    Surge protection features:
    Nominal discharge current ln(8/20μs) 5kA
    Voltage protection level Up(8/20μs): 60V(line to line)
    Voltage protection level Up(8/20μs): 600V(line to ground)
    According to standards GB/T18802.21-2016(equivalent to 1EC61643-21:2012)
    Supply voltage 20-35VDC
    Power consumption Current output <0.8W; voltage output <0.6W (PHG-11TT+ series)
    Current output <1.2W; voltage output <0.6W (PHG-12TT+ series)
    LED indicator  Green: Power indicator
    Low range alarm L1 light on, high range alarm L2 light on
    Output accuracy Please refer to the "Input Signal Type and Range Table" for details
    Response time Reaching 90% of the final value within 300ms
    Temperature drift 0.005%F.S/℃
    Temperature parameters Working temperature: -20℃~+60℃, storage temperature:-40℃~+80℃
    Relative humidity 10%~95% RH no condensation
    Insulation strength ≥2000VAC/min  (between input/output/power supply)
    Insulation resistance 100MΩ(500V DC)   (between input/output/power supply)
    Electromagnetic compatibility GB/T 18268 (IEC 61326-1)
    MTBF 800000h
    Wire requirements Horizontal cutting surface ≥ 0.5mm2; Insulation strength ≥ 500V
    Applicable field equipments K. S, E, J, B, T, R, N TC sensors

    Dimension

    PHG-11TT+.jpg

     Schematic diagram

    PHG-11TT+(1).jpg

    Note:

    1. PHG-11TT+does not include output part 2

    2. The power rail function is an optional function, and users need to specify the power supply method when placing an order

    The selection of power rail connectors can refer to page 89 of the "Annex"

    Specification, model and code

    Input signal types and measurement range
    Code TC model Measurement range Minimum range Conversion accuracy
    1 K -200~1370℃ 50℃ 0.5℃/0.1%
    2 S -50~1760℃ 500℃ 1.5℃/0.1%
    3 E -140~1000℃ 50℃ 0.5℃/0.1%
    4 J -160~1200℃ 50℃ 0.5℃/0.1%
    5 B 250~1800℃ 500℃ 1.5℃/0.1%
    6 T -200~400℃ 50℃ 0.5℃/0.1%
    7 R -50~1760℃ 500℃ 1.5℃/0.1%
    8 N -200~1300℃ 50℃ 0.5℃/0.1%

     

    Output parameter definition
    Code Parameter
    1 4~20mA
    2 0~20mA
    3 0~5V
    4 0~10V
    5 1~5V
    6 0~75mV
    7 土10V
    8 Customized

    PHG-11TT+ (2).jpg

    For example: one input and two outputs, thermocouple K (-200~1370°C) input, two 4~20mA outputs, 24V power supply, model: PHG-12TT-111+