English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Get Instant Quote
Leave Your Message
PHD-22TF-2828
Digital Input
Products Categories
Featured Products

PHD-22TF-2828

PHD-22TF-2828

Proximity switch Contact input /Transistor output 2 input 2 output


Overview

Isolated safety barrier at detection side: PHD-22TF-2828, digital input and output, dual input and dual output.

    Overview

    The isolated safety barrier with switch input transistor output, which isolates and transmits input signals from switch contacts or proximity switches in hazardous areas to the safety zone with output transistor through the safety barrier. Line fault detection is achieved through LED on the top of the module. The dial switch of the module is used to set input and output in-phase or reverse control, as well as to enable or disable the line fault detection alarm indication function. This product requires independent power supply, with isolated power supply, input, and output terminals.

     

    图片 1

     

    Supply voltage 20~35VDC, power consumption<1.0W
    Input signal Switch contact/proximity switch
    Supply voltage from sensor side on site 8V
    Signal input characteristics On-site input current: >2.1mA, it means ON; On-site input current: <1.2mA, it means OFF  Switch hysteresis: 0.2ms
    Transistor output characteristics NPN type transistor emitter or collector open circuit output, drive capacity: output current ≤20mA (1.2KΩ), internal maximum current 100mA. Equipped with short-circuit current protection
    Switched control between inverted phase and normal phase of outputs e-c When the dial switch K1 is at "ON", the transistor output e-c are in inverted phase
    When the dial switch K1 is at "OFF", the transistor output e-c are in normal phase
    When the K2 is at  "ON", the circut will select the red light indication alarm function
    Indicating light alarm function Field input current >7mA, short-circuit alarm (SC), on-site input current < 0.1mA, open-circuit alarm (LB). Switch contact input, when disconnection detection function is required, a 10kΩ resistor should be connected in parallel at both ends of the switch (Please see the switch contact II in the wiring diagram below).
    Number of input and output 2 input 2 output
    Applicable field equipments Dry contact or NAMUR proximity switch in accordance with DIN 19234 standard.
    Temperature parameter Working temperature: -20℃~+60℃, storage temperature:-40℃~+80℃
    Relative air humidity 10%~95%RH without condensation
    Dielectric strength Between intrinsically safe side and non-intrinsically safe side (≥ 3000VAC/min); between power supply and non-intrinsically safe terminal (≥ 1500VAC/min)
    Insulation resistance ≥100MΩ (between input/output/power supply)
    External dimensions Thickness 12.5mm x width 108mm x high 118mm
    Electromagnetic compatibility According to IEC 61326-1(GB/T 18268), IEC 61326-3-1
    Explosion-proof mark [Exia Ga]IIC
    Functional safety certification SIL3 according to IEC 61508 EN 61511 standards
    Certification Body CQST(China National Quality Supervision and Test Centre for Explosion Protected Electrical Products)
    Certified parameters (between terminals1-2,  3-4) Um=250V  Uo=10.5V  Io=15mA  Co=1.7μF  Lo=150mH  Po=39.4mW
    Installation site Requirements It can be connected with instruments in 0 zone with ⅡA, ⅡB, ⅡC dangerous gas