Icelandic
English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Fáðu tilboð strax
Leave Your Message
PHD-11TP-11M PHD-12TP-111M
Tíðninntak
Vöruflokkar
Valdar vörur

PHD-11TP-11M PHD-12TP-111M

PHD-11TP-11M 1 inntak 1 úttak

PHD-12TP-111M 1 inntak 2 útgangar

Inntak: Tíðnimerki
Úttak: DC merki, viðvörunarkerfi

    Yfirlit

    Tíðninntaksmerkiseinangrari, breytir tíðnimerkinu við innganginn í jafnstraumsmerkisútgang fyrir öryggishindrun í samræmi við það bil sem notandinn stillir, hann hefur einnig viðvörunarútgang fyrir rafleiðara.
    Þessi vara þarfnast sjálfstæðs aflgjafa og aflgjafinn, inntakið og úttakið eru einangruð hvert frá öðru.

     

    PHD-11TP-11M PHD-12TP-111M 1Upplýsingar

    Upplýsingar

    Inntak á hættusvæði

     

    Tegund merkis

    1) þriggja víra PNP/NPN skynjarainntak:
    Dreifing skynjara: (2+, 15, 3-): 14V,
    Núverandi:
    Inntakstíðni: 0,1Hz ~ 100kHz

    2) Tíðnimerkisinntak:
    Inntakstíðni: 0,1Hz ~ 100kHz
    Hámarks leyfileg inntaksspenna: 30Vp-p
    Lágmarksinntaksstig: 0,2V (2Hz ~ 100kHz)
                                           2V (0,1Hz ~ 100kHz)

    3) Nálægðarrofi, inntak þurrsnertisrofa:
    Dreifingarspenna: (4+, 5-) ≈8V, skammhlaupsstraumur: (4+, 5-) >7mA
    Inntakstíðni: 0,1Hz ~ 100kHz

    Úttak á öruggu svæði

     

    Útgangsmerki

    0~20mA, 4~20mA, 0~5V, 0~10V

    Núverandi úttaksálagsþol

    Spennuútgangsálagsþol

    ≥300Ω

    Grunnbreytur

     

    Rafmagnsgjafi

    20~35V jafnstraumur

    Orkunotkun

    ≤85mA (24V aflgjafi, 20mA úttak)

    Breidd höggs

    ≥2μs

    Nákvæmni úttaks

    0,1% FS

    Hitastigsbreyting

    0,01% FS/°C

    Nánari upplýsingar um greiningu á bilun í inntaksmerki er að finna í viðeigandi handbók.

    Svarstími relay

    20ms

    Vinnuhitastig

    -20°C~+60°C

    geymsluhitastig

    -40°C~+80°C

    Rakastig

    10%~95%RH (engin þétting)

    Rafsegulfræðilegur mælikvarði

    Samkvæmt GB/T 18268 (IEC 61326-1)

    Einangrunarstyrkur

    Milli sjálfsöruggrar hliðar og ekki sjálfsöruggrar hliðar ≥2500V AC/mín
    Milli aflgjafa og hliðar sem ekki er sjálförugg ≥2500V AC/mín

    Einangrunarviðnám

    ≥100MΩ (milli inntaks/úttaks/aflgjafa)

    Kröfur um vír

    Þversnið ≥0,5 mm²; Einangrunarstyrkur ≥500V

    Uppsetningarstaður

    Þegar það er sett upp á öruggu svæði er hægt að tengja það við innri öryggistæki á hættulegum svæðum allt að svæði 0, IIC, svæði 20 og IIIC.

    Viðeigandi búnaður á vettvangi

    Samkvæmt DIN19234 NAMUR nálægðarrofi, þurr snertirofi o.fl. vettvangstæki (þar á meðal innri þrýstirofi, hitarofi og vökvastigsrofi o.fl.), stigsmæling, þriggja víra PNP/NPN skynjaraútgangur, stigvaxandi kóðari

    Öryggisvottun

     

    Sprengjuvarnarmerki

    [Exia Ga] IIC [Exia Frá] IIIC

    Sprengjuheldur staðall

    GB/T 3836.1-2021, GB/T 3836.4-2021

    Flugstöðvar 4-5

    Um=250VAC/DC, Uo=10,5VDC, Io=14mA,
    Po=37mW, Co=2,4μF, Lo=165mH

    Tengistöðvar 3-6

    Um=250VAC/DC, Uo=14VDC, Io=8mA,
    Po=28mW,Co=0.73μF,Lo=150mH

    Tengistöðvar 1-2-3

    Um=250VAC/DC, Uo=17,5VDC, Io=330mA,
    Po=1,4W,Co=0,375μF,Lo=0,22mH

    Vottunaraðili

    Skoðunar- og prófunarstofnun Sjanghæ fyrir tækjabúnað og sjálfvirknikerfi (SITIIAS)


    PHD-11TP-11M PHD-12TP-111M


    Athugið:
    1. PHD-11TP-11M inniheldur ekki úttakshluta 2. 2. Rafmagnsleiðarvirknin er valfrjáls og notendur þurfa að tilgreina aflgjafaaðferðina þegar þeir panta. Val á tengjum fyrir rafmagnsleiðara er að finna á bls. 89 í „Viðaukanum“.


    Sækja_skrá