English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Dapetken Kutipen Instan .
Leave Your Message
PHD-11TP-11M PHD-12TP-111M
Masukken Frekuensi .
Kategori Produk .
Produk si ipilih

PHD-11TP-11M PHD-12TP-111M

11TP-11M 1 masuken 1 keluaren

12TP-111M 1 masuken 2 keluaren

Masuken:Sinyal frekuensi .
Keluaren: sinyal DC, alarm relay

    Gambaren

    Isolator sinyal masuken frekuensi, mengubah sinyal frekuensi ibas ujung masuken jadi keluaren sinyal DC ku penghalang keselamaten sue ras rentang si itetapken pengguna, ia pe lit keluaren alarm relay.
    Produk enda perlu bertenaga mandiri, janah pasoken daya, masuk ras keluar terisolasi sada ras si debanna.

     

    11Tp-11M PHD-12TP-111M 1Spesifikasi

    Spesifikasi

    Masukken i bas daerah si berbahaya .

     

    Jenis sinyal

    1) telu kawat masuk sensor PNP/NPN : 1.1.
    2+ 15 3-): 14V,
    Arus:
    Frekuensi si masuk: 0,1Hz ~ 100kHz

    2) Frekuensi sinyal si masuk : 1.1.
    Frekuensi masuken:0,1Hz~100kHz
    Tegangan masuk si maksimal si banci ibereken: 30Vp-p .
    Tingkat masuken si minimal: 0,2V (2Hz ~ 100kHz)
                                           2V (0,1Hz~100kHz)

    3) Saklar kedekatan, masuken saklar kontak kering : 1.1.
    Tegangan distribusi:(4+、5-)≈8V,Arus rangkaian pendek:(4+、5-)>7mA
    Frekuensi masuken :0,1Hz~100kHz

    Keluaren i bas daerah si aman .

     

    Sinyal si ndarat

    0~20mA"4~20mA"0~5V"0~10V

    Tahanen beban si ndarat genduari .

    Tegangan keluaren beban tahan .

    ≥300Ω

    Parameter dasarna .

     

    Pasoken listrik .

    20~35V DC

    Konsumsi daya .

    ≤85mA (24V catu daya, 20mA keluaren)

    Lebar impuls .

    ≥2s

    Akurasi keluaren .

    0,1% FS

    Suhu si ergeser .

    0,01% FS/°C

    Guna meteh terbuen kerna fungsi deteksi kesalahan sinyal masuk, nehenlah buku petunjuk si berlaku .

    Respon waktu estafet .

    20ms

    Suhu erdahin .

    -20°C~+60°C

    suhu penyimpanan

    -40°C~+80°C

    Kelembapen si relatif

    10%~95%RH (la lit kondensasi)

    EMC

    Menurut GB/T 18268 (IEC 61326-1) .

    Kekuatan isolasi .

    Antara sisi si aman secara intrinsik ras sisi si la aman secara intrinsik≥2500V AC/min
    Antara catu daya ras sisi si la aman secara intrinsik ≥2500V AC/min .

    Ketahanen isolasi .

    ≥100MΩ(antara masuken/keluaren/pasoken listrik)

    Persyaraten kawat .

    Penampang ≥0,5mm2;Kekuatan isolasi ≥500V

    Ingan pemasangan .

    Ipasang i bas zona aman, banci ihubungken ku alat keselamaten intrinsik i bas daerah si berbahaya seh ku Zona 0, IIC, Zona 20, ras IIIC .

    Peralaten lapangan si berlaku .

    Menurut DIN19234 NAMUR saklar kedekatan, saklar kontak kering rsd alat lapangan (termasuk saklar tekanan intinsic, saklar suhu ras saklar tingkat cair rsd) , sinyal impuls tingkat, keluaren sensor PNP/NPN telu kawat, encoder inkremental .

    Sertifikasi keselamaten .

     

    Tanda si tahan ledaken .

    [Eksia Ga] IIC [Eksia I bas] IIIC .

    Standar si tahan ledaken .

    3836,1-2021, ras 3836,4-2021

    Terminal si lit i bas 4-5.

    Um=250VAC/DC,Uo=10,5VDC,Io=14mA,
    Po=37mW,Co=2,4mF,Lo=165mH

    Terminal si lit i bas 3-6.

    Um=250VAC/DC,Uo=14VDC,Io=8mA,
    Po=28mW,Co=0,73mF,Lo=150mH

    Terminal 1-2-3.

    Um=250VAC/DC,Uo=17,5VDC,Io=330mA,
    Po=1,4W,Co=0,375μF,Lo=0,22mH

    Badan si mereken sertifikasi .

    Lembaga Pemeriksaan ras Pengujian Instrumen ras Sistem Otomasi i Shanghai (SITIIAS)


    PHD-11TP-11M PHD-12TP-111M


    Cataten:
    1、PHD-11TP-11M la termasuk output part 2 2、Fungsi rel daya eme fungsi opsional, janah pengguna perlu nentuken cara pasoken listrik sanga erbahan pesanen Pemilihen konektor rel daya banci idahndu i bas halamen 89 “Lampiren”.


    Unduh_berkas