English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
立即获取报价
Leave Your Message
PHC-22TD-1111
模拟输出
产品类别
特色产品

PHC-22TD-1111

PHC-22TD-1111 2个输入 2个输出

输入:4~20mA(HART数字信号)
输出:4~20mA(HART数字信号)

    概述

    该模拟输出隔离式安全屏障可实现安全区仪表4~20mA信号向危险区的隔离传输,驱动现场阀门定位器、电/气转换器等设备,并支持HART数字信号的双向传输。本产品需独立供电,且电源、输入和输出均相互隔离。

     

    PHC-22TD-1111-4

     

    供电电压
    20~35V 直流,功耗:≤90mA(电源供电,20mA 输出)
    输入信号 4~20mA(HART)
    输出信号 4~20mA(HART)
    负载阻力 输出电流20mA,阻抗0~800Ω(可定制)
    输入和输出通道的数量 2 个输入 2 个输出
    适用的现场设备 阀门定位器,电动/气动转换器
    温度参数 工作温度:-20℃~+60℃,存储温度:-40℃~+80℃
    相对湿度 相对湿度10%~95% 无冷凝
    介电强度 本质安全侧与非本质安全侧之间(≥ 3000VAC/min);电源与非本质安全端子之间(≥ 1500VAC/min)
    绝缘电阻 ≥100MΩ(输入/输出/电源之间)
    外部尺寸 厚度 12.5 毫米 x 宽度 108 毫米 x 高 118 毫米
    电磁兼容性 根据 IEC 61326-1(GB/T 18268)、IEC 61326-3-1
    防爆标志 [Ex ia Ga] IIC [Ex ia Da] ⅢC
    认证机构 中国防爆电气产品国家质量监督检验中心(CQST)
    1-2号航站楼,3-4号航站楼
    嗯:250V AC/DC Uo=28V DC Io=93mA
    Po=0.65W Co=0.083μF Lo=4.2mH
    安装场地要求

    安装在安全区域内,它可以连接到 危险区域的本质安全型仪表 最高可达 0 区、IIC 区、20 区和 IIIC 区

    平均故障间隔时间 大约100000小时



    phc-2td-1111

    注意:电源轨的供电是可选功能。用户需要……
    订购时请注明电源模式。请参阅附件。