I-PHD-11TT-*8
Isishwankathelo
Umqobo wokhuseleko wokufakwa kwe-thermocouple ungadlulisela isignali ye-millivolt ukusuka kwi-thermocouple (TC) kwindawo eyingozi ukuya kwindawo ekhuselekileyo nge-1: 1.
Le mveliso ifuna umbane ozimeleyo, kunye nombane ohlukeneyo, i-input, kunye nee-output terminals.
"*" imele uhlobo lokufaka lwe-thermocouple, kwaye imodeli ethile imelwe yikhowudi (jonga "Uhlobo lweSignali yokungenisa kunye neTheyibhile yoLuhlu" ukuze ufumane iinkcukacha).
| Iintlobo zesignali yokufaka kunye noluhlu lokulinganisa | ||||
| Ikhowudi | Imodeli ye-TC | Uluhlu lokulinganisa | Uluhlu oluncinci | Ukuchaneka kokuguqulwa |
| 1 | K | -200~1370℃ | 50℃ | 0.5℃/0.1% |
| 2 | S | -50~1760℃ | 500℃ | 1.5℃/0.1% |
| 3 | KWAYE | -140~1000℃ | 50℃ | 0.5℃/0.1% |
| 4 | J | -160~1200℃ | 50℃ | 0.5℃/0.1% |
| 5 | B | 250~1800℃ | 500℃ | 1.5℃/0.1% |
| 6 | T | -200~400℃ | 50℃ | 0.5℃/0.1% |
| 7 | R | -50~1760℃ | 500℃ | 1.5℃/0.1% |
| 8 | N | -200~1300℃ | 50℃ | 0.5℃/0.1% |
Iinkcukacha
| Igalelo kwindawo enobungozi | |
| Isignali yokufaka | Imiqondiso ye-thermocouple ye-K, S, E, J, B, T, R, N (jonga "Uhlobo lweSignali yokufaka kunye neTheyibhile yoLuhlu" ngeenkcukacha) |
| Uluhlu lwesignali | -20~80mV. |
| Isiphumo secala lokhuseleko: | |
| Isignali yesiphumo | I-Thermocouple 1: 1 |
| Isalathisi se-LED | Oluhlaza: Isalathisi samandla |
| Ukuchaneka kwemveliso | 0.05%FS |
| Ixesha lokuphendula | Ukufikelela kwi-90% yexabiso lokugqibela ngaphakathi kwe-300ms |
| Ukushukuma kobushushu | 0.005%FS/℃ |
| Iiparamitha zobushushu | Ubushushu obusebenzayo: -20℃~+60℃, ubushushu bokugcina:-40℃~+80℃ |
| Ubuntu bezizalwane | 10% ~ 95% RH akukho ukufuma |
| Amandla e-dielectric | Phakathi kwecala elikhuselekileyo ngokwangaphakathi kunye necala elikhuselekileyo ngokwangaphakathi (≥ 3000VAC/min); phakathi kombane kunye nesiphelo esingakhuselekanga ngaphakathi (≥ 1500VAC/min) |
| Ukumelana nobushushu | ≥100MΩ (phakathi kokufaka/ukukhupha/umbane) |
| Ukuhambelana kwe-electromagnetic | Ngokwe-IEC 61326-1(GB/T 18268), IEC 61326-3-1 |
| I-MTBF | 100000h |
| Iimfuno zentambo | Icandelo elinqamlezileyo ≥ 0.5mm2; Amandla okukhusela ≥ 500V |
| Izixhobo zasentsimini ezisebenzayo | Izinzwa ze-TC ze-K. S, E, J, B, T, R, N |
| Indawo yokufakela | Ifakwe kwindawo ekhuselekileyo, inokuqhagamshelwa kwizixhobo zokhuseleko zangaphakathi kwiindawo ezinobungozi ukuya kuthi ga kwiZone 0, IIC, Zone 20, kunye ne-IIIC. |
Ubukhulu

Umzobo wesicwangciso

Phawula:
1. Umsebenzi wesitimela samandla ngumsebenzi onganyanzelekanga, kwaye abasebenzisi kufuneka bachaze indlela yokubonelela ngombane xa bebeka iodolo
Ukukhethwa kwezihlanganisi zesitimela samandla kunokubhekisa kwiphepha lama-89 le "Annex"
Isatifikethi esikhuselekileyo ngokwendalo
| Uphawu lobungqina bokuqhuma | [Ex ia Ga]lIC [Ex ia Da]lllC |
| Umgangatho omelana nokuqhuma | GB/T3836.1-2021 GB/T3836.4-2021 |
| IiTerminali 3-4 | Um:250V AC/DC Uo=8.4V DC lo=31mA Po=65.1mW Co=4.8μF Lo=20mH |
| Umbutho wesiqinisekiso | I-CQST (iZiko leSizwe laseTshayina lokuLawula kunye noVavanyo loMgangatho lweeMveliso zoMbane eziKhuselweyo zoQhushu) |