English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Obter un orzamento instantáneo
Leave Your Message
PHD-11TT-*8
Entrada de temperatura
Categorías de produtos
Produtos destacados

PHD-11TT-*8

Barreira de seguridade illada de entrada TC

1 entrada 1 saída

Entrada de sinal TC

Saída de sinal de 1:1 milivoltios

    Visión xeral

    A barreira de seguridade de illamento de entrada de termopar pode transmitir o sinal de milivoltios do termopar (TC) na zona perigosa á zona segura en proporción de 1:1.

    Este produto require unha fonte de alimentación independente, con fonte de alimentación illada, terminais de entrada e saída.

    "*" representa o tipo de entrada do termopar e o modelo específico represéntase mediante un código (consulte a "Táboa de tipos e rangos de sinal de entrada" para obter máis detalles).

    Tipos de sinal de entrada e rango de medición
    Código Modelo TC Rango de medición Alcance mínimo Precisión da conversión
    1 K -200~1370℃ 50 ℃ 0,5 ℃/0,1%
    2 S -50~1760℃ 500 ℃ 1,5 ℃/0,1%
    3 E -140~1000℃ 50 ℃ 0,5 ℃/0,1%
    4 J -160~1200℃ 50 ℃ 0,5 ℃/0,1%
    5 B 250~1800 ℃ 500 ℃ 1,5 ℃/0,1%
    6 T -200~400℃ 50 ℃ 0,5 ℃/0,1%
    7 R -50~1760℃ 500 ℃ 1,5 ℃/0,1%
    8 N -200~1300℃ 50 ℃ 0,5 ℃/0,1%

    Especificacións

    Entrada en zona perigosa  
    Sinal de entrada Sinais de termopar K, S, E, J, B, T, R, N (consulte a "Táboa de tipos e rangos de sinal de entrada" para obter máis detalles)
    Rango de sinal -20~80mV.
    Saída do lado de seguridade:  
    Sinal de saída Termopar 1:1
    Indicador LED Verde: Indicador de acendido
    Precisión de saída 0,05 % de peso enerxético
    Tempo de resposta Alcanzar o 90 % do valor final en 300 ms
    Deriva de temperatura 0,005 % de temperatura de fondo libre/℃
    Parámetros de temperatura Temperatura de traballo: -20 ℃ ~ +60 ℃, temperatura de almacenamento: -40 ℃ ~ +80 ℃
    Humidade relativa 10 %~95 % de HR sen condensación
    Rixidez dieléctrica Entre o lado intrínsecamente seguro e o lado non intrínsecamente seguro (≥ 3000 V CA/min);
    entre a fonte de alimentación e o terminal non intrínsecamente seguro (≥ 1500 V CA/min)
    Resistencia de illamento ≥100 MΩ (entre entrada/saída/fonte de alimentación)
    Compatibilidade electromagnética Segundo a norma IEC 61326-1 (GB/T 18268), IEC 61326-3-1
    MTBF 100000 h
    Requisitos de cableado Sección transversal ≥ 0,5 mm2; Resistencia de illamento ≥ 500 V
    Equipos de campo aplicables Sensores TC K. S, E, J, B, T, R, N
    Lugar de instalación Instalado nunha zona segura, pódese conectar a instrumentos de seguridade intrínseca en áreas perigosas ata a Zona 0, IIC, Zona 20 e IIIC

    Dimensión

    PHD-11T-X8.jpg

    Diagrama esquemático

    PHD-11T-X8(1)799

    Nota:

    1. A función de raíl eléctrico é opcional e os usuarios deben especificar o método de subministración de enerxía ao realizar un pedido.

    A selección de conectores de raíl de alimentación pode consultarse na páxina 89 do "Anexo"

    Certificación intrínsecamente segura

    Marca a proba de explosións [Ex ia Ga]lIC [Ex ia Da]lllC
    Estándar a proba de explosións GB/T3836.1-2021 GB/T3836.4-2021
    Terminais 3-4 Um: 250 V CA/CC Uo=8,4 V CC lo=31 mA
    Po=65,1 mW Co=4,8 μF Lo=20 mH
    organismo de certificación CQST (Centro Nacional de Supervisión e Probas de Calidade de Produtos Eléctricos con Protección contra Explosións da China)