English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Obter un orzamento instantáneo
Leave Your Message
PHD-11TZ-46
Entrada de temperatura
Categorías de produtos
Produtos destacados

PHD-11TZ-46

Sinal RTD Pt100 de dous ou tres fíos

Sinal RTD Pt100

    Visión xeral

    As barreiras de seguridade illadas con entrada de resistencia térmica poden transmitir o sinal de resistencia térmica (RTD) Pt100 de dous ou tres fíos da zona perigosa á zona segura 1:1.
    Este produto require unha fonte de alimentación independente, con fonte de alimentación illada, terminais de entrada e saída.

     

    Imaxe 1

     

    Entrada en zona perigosa
    Sinal de entrada Sinal RTD Pt100 de dous ou tres fíos
    Rango de medición -200-850
    Saída do lado de seguridade:
    Sinal de saída Sinal RTD Pt100
    corrente de excitación 0,1-3 mA
    Tensión de subministración 20-35 V CC
    Consumo de enerxía ≤40 mA (cando a fonte de alimentación é de 24 V CC) 
    Indicador LED  Verde: Indicador de acendido
    Precisión de saída 0,1 % de peso enteiro
    Deriva de temperatura 0,1 % de profundidade de carga/10 ℃
    Parámetros de temperatura Temperatura de traballo: -20~+60, temperatura de almacenamento: -40~+80
    Humidade relativa 10 %~95 % de HR sen condensación
    Rixidez dieléctrica Entre o lado intrínsecamente seguro e o lado non intrínsecamente seguro (≥ 3000 V CA/min);
    entre a fonte de alimentación e o terminal non intrínsecamente seguro (≥ 1500 V CA/min)
    Resistencia de illamento ≥100 MΩ (entre entrada/saída/fonte de alimentación)
    Compatibilidade electromagnética Segundo a norma IEC 61326-1 (GB/T 18268), IEC 61326-3-1
    MTBF 100000 h
    Requisitos de cableado Sección transversal ≥ 0,5 mm2; Resistencia de illamento ≥ 500 V
    Equipos de campo aplicables RTD Pt100 de dous ou tres fíos
    Lugar de instalación Instalado nunha zona segura, pódese conectar a instrumentos de seguridade intrínseca en áreas perigosas ata a Zona 0, IIC, Zona 20 e IIIC
    Certificación de seguridade
    Marca a proba de explosións [Ex ia Ga]lIC [Ex ia Da]lllC
    Estándar a proba de explosións GB/T3836.1-2021  GB/T3836.4-2021
    Terminais 3-24-2 Um: 250 V CA/CC Uo=8,4 V CC lo=31 mA
    Po=65,1 mW Co=4,8 μF Lo=20 mH
    organismo de certificación CQST (Centro Nacional de Supervisión e Probas de Calidade de Produtos Eléctricos con Protección contra Explosións da China)



    phd-11tz-46

    Nota: 1. A función do carril de alimentación é opcional e os usuarios deben especificar o método de subministración de enerxía ao realizar un pedido

    A selección de conectores de raíl de alimentación pode consultarse na páxina 89 do "Anexo"

    2. Ao introducir un RTD de tres fíos, é necesario asegurarse de que os tres os fíos teñen a mesma lonxitude tanto como sexa posible

    3. Ao introducir unha termorresistencia de dous cables, os terminais 4 e 2 da barreira de seguridade deben estar curtocircuíto