- Tashar Jiragen Sama
- Shingayen Tsaro da Aka Keɓe
- Masu Rarraba Sigina
- Na'urorin Kariya Masu Tasowa
- Tsaron jigilar kaya
- Modules na I/O masu Hankali da Aka Raba
- Ƙofofin Wayo Masu Hankali
- Masu Canja wurin Bayanan Masana'antu
- Masu Nazarin Dew Point na Kan layi
- Sassan Samun Bayanai
- Mai canza bayanai na HART
0102030405
PHD-11TZ-46
Bayani
Shigar da juriyar zafi mai keɓewa daga shingen tsaro na iya aika siginar juriyar zafi mai waya biyu ko waya uku (RTD) Pt100 a cikin yankin mai haɗari zuwa yankin aminci 1: 1.
Wannan samfurin yana buƙatar samar da wutar lantarki mai zaman kanta, tare da samar da wutar lantarki mai zaman kanta, shigarwa, da tashoshin fitarwa.
| Shigarwa a cikin yanki mai haɗari | |
| Siginar shigarwa | Waya biyu ko waya uku RTD Pt100 siginar |
| Kewayon aunawa | -200℃-850℃ |
| Tsaro gefen fitarwa: | |
| Siginar fitarwa | Siginar RTD Pt100 |
| Wutar lantarki | 0.1-3mA |
| Ƙarfin wutar lantarki | 20-35VDC |
| Amfani da wutar lantarki | ≤40mA (lokacin da wutar lantarki ta 24VDC) |
| Alamar LED | Kore: Alamar wuta |
| Daidaiton fitarwa | 0.1%FS |
| Juyawar yanayin zafi | 0.1% FS/10℃ |
| Sigogin zafin jiki | Zafin aiki: -20℃~+60℃, zafin ajiya:-40℃~+80℃ |
| Danshin da ya dace | 10% ~ 95% RH babu danshi |
| Ƙarfin Dielectric | Tsakanin ɓangaren da ke da aminci a cikin jiki da ɓangaren da ba shi da aminci a cikin jiki (≥ 3000VAC/min); |
| tsakanin wutar lantarki da tashar da ba ta da aminci a cikin jiki (≥ 1500VAC/min) | |
| Juriyar rufi | ≥100MΩ (tsakanin shigarwa/fitarwa/ samar da wutar lantarki) |
| Dacewar na'urar lantarki | A cewar IEC 61326-1(GB/T 18268), IEC 61326-3-1 |
| MTBF | 100000h |
| Bukatun waya | Sashe na giciye ≥ 0.5mm2; Ƙarfin rufi ≥ 500V |
| Kayan aikin filin da suka dace | Wayoyi biyu ko waya uku RTD Pt100 |
| Wurin shigarwa | An sanya shi a cikin yankin aminci, ana iya haɗa shi da kayan aikin tsaro na ciki a cikin yankuna masu haɗari har zuwa Yanki 0, IIC, Yanki 20, da IIIC. |
| Takaddun shaida na aminci | |
| Alamar tabbatar fashewa | [Ex ia Ga]lIC [Ex ia Da]lllC |
| Ma'aunin kariya daga fashewa | GB/T3836.1-2021 GB/T3836.4-2021 |
| Tashoshi 3-2、4-2 | Um:250V AC/DC Uo=8.4V DC lo=31mA |
| Po=65.1mW Co=4.8μF Lo=20mH | |
| Hukumar ba da takardar shaida | CQST (Cibiyar Kula da Ingancin Ƙasa da Gwaji ta Kare Kayayyakin Wutar Lantarki ta Ƙasa ta China) |

Lura: 1. Aikin layin wutar lantarki aiki ne na zaɓi, kuma masu amfani suna buƙatar ƙayyadewa hanyar samar da wutar lantarki lokacin yin oda
Zaɓin haɗin layin wutar lantarki zai iya komawa zuwa shafi na 89 na "Annex"
2. Lokacin shigar da RTD mai waya uku, ya zama dole a tabbatar da cewa ukun Wayoyi suna da tsayi iri ɗaya gwargwadon iyawa
3. Lokacin shigar da RTD mai waya biyu, dole ne a sanya tashoshin shingen tsaro 4 da 2 gajeriyar hanyar sadarwa


PHD-11TC-33A-23