English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Accipe Estimationem Statim
Leave Your Message
PHC-11HF-14
Series H Backplane Mounting Isolated Security Claustres
Categoriae Productorum
Producta Insignia

PHC-11HF-14

Ingressus/commutator contactus et gradus logici exitus gubernans
Claustra Securitatis Isolata ad Fixationem in Plano Posteriore Seriei H
1 ingressus 1 egressus

    Conspectus

    Claustra securitatis isolata seriei H in latere operationis, cum installatione posteriori plani: PHC-11HF-14, cum introitu et exitu digitali, uno introitu et uno exitu.

    Claustrum securitatis quantitatem ingressam contactus commutatoris et gradus logici in area securitatis in quantitatem impulsivam instrumentorum intrinsece tutorum convertere et in campum areae periculosae emittere potest, ut valvulam solenoidem, alarmum audibilem et visualem, etc. moderetur.

    Indicator status luces rubras et flavas habet; cum alarma est, lumen rubrum est; cum autem cum valvula solenoidis exitus est, lumen flavum est.

    Hoc productum fontem potentiae separatum requirit.

    Tensio alimentationis 20~35VDC, consumptio potentiae
    Signum ingressus Contactus commutatorius, gradus logicus
    Signum egressus Tensio circuitus aperti > 24V, UE/IE = 12.8V/48mA
    Functio inversionis: K1 ad latus "ON" ponitur, egressus circuitus invertitur.
    Functio relais alarmis Interruptor rotatorius K2 in latus "ON" positus est, circuitus functionem alarmi assumit.
    Resistentia oneris 10KΩ, alarmum circuitus aperti (LB)
    Proprietates exitus relais alarmis Tempus responsionis: 20ms, capacitas impulsiva: 250VAC/2A, 30VDC/2A sub onere resistivo
    Numerus input et output 1 ingressus 1 egressus
    Instrumenta agrorum applicabilia Valvula solenoidis securitatis, alarmum audibile et visuale
    Parametri temperaturae Temperatura operandi: -20℃~+60℃, temperatura repositionis: -40℃~+80℃
    Humiditas relativa 10%~95% RH nulla condensatio
    Robur dielectricum Inter latus intrinsece tutum et latus non intrinsece tutum (≥3000VAC/min); inter fontem potentiae et terminale non intrinsece tutum (≥1500VAC/min)
    Resistentia insulationis ≥100MΩ (inter input/output/power supply)
    Dimensiones Crassitudo 15.8mm * latitudo 104.8mm * altitudo 116.1mm
    Compatibilitas electromagnetica Secundum IEC 61326-1 (GB/T 18268), IEC 61326-3-1
    Signum explosionibus resistens [Exia Ga]IIC, [Exia Da]IIIC
    Norma certificationis GB/T 3836.1-22021, GB/T 3836.4-2021
    Corpus certificationis CQST (Centrum Nationale Sinense Supervisionis Qualitatis et Probationis pro Productis Electricis Explosionibus Protectis)
    Parametri probati (inter terminales 2-1) Um:250VAC/DC Uo=25.2V Io=147mA Po=0.92W Co=0.107μF Lo=1.5mH
    Requisita loci institutionis

    In zona tuta installatum, instrumentis securitatis intrinsecae in locis periculosis usque ad Zonam 0, IIC, Zonam 20, et IIIC coniungi potest.

    MTBF ≤100000h