Latin
English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Accipe Estimationem Statim
Leave Your Message
PHD-12HZ-*11
Series H Backplane Mounting Isolated Security Claustres
Categoriae Productorum
Producta Insignia

PHD-12HZ-*11

Ingressus RTD / egressus 4~20mA (configurabilis)
Claustra Securitatis Isolata ad Fixationem in Plano Posteriore Seriei H
1 ingressus 2 exitus

    Conspectus

    PHD-12HZ-*11 signa detectoris resistentiae temperaturae (RTD) in area periculosa in signa currentiae 4~20mA convertit, ad onera in area tuta movenda. Configuratio intellegens praesto est, et ambitus actualis RTD programmate computatrali constitui potest. Functione alarmis filum ruptum et functione alarmis extra ambitum habet. Productum separatam fontem potentiae requirit cum triplici isolatione pro potentia, ingressu et ingressu. "*" genus ingressum thermocoupli, exemplar specificum cum codice indicat (vide figuram infra).


    Genera signorum ingressus et spatium mensurae

    Codex

    exemplar RTD

    Spatium mensurae

    Spatium minimum

    Accuratio conversionis

    1

    G53

    -50~150℃

    20℃

    0.2℃/0.1%

    Duo

    G50

    -50~150℃

    20℃

    0.2℃/0.1%

    quattuor

    Pt100

    -200~850℃

    20℃

    0.2℃/0.1%

    sex

    Pt1000

    -200~850℃

    20℃

    0.2℃/0.1%

    VII

    Ni1000

    -60~250℃

    20℃

    0.2℃/0.1%

     

     


    Parametri technici principales

    Numerus canalium:

    unus ingressus et duo exitus

    Fons potentiae:

     

    Tensio potentiae:

    20~35V DC, consumptio potentiae circiter 1.8W (24V DC, egressus 20mA)

    Protectio potentiae:

    praesidium inversum potentiae

    Ingressus lateris periculosi:

     

    Signum Ingressus:

    Signum RTD bifilarium vel trifilarium (vide "Tabulam Typi et Ambitus Signi Ingressus")

    Ambitus signalis:

    Correspondens ambitui mensurae RTDorum.

    Spatium mensurae:

    Usui ut propriam configurationem evolvat cum iubet, in numero finali vel aliis instructionibus specificatam.

    Exitus lateris securitatis:

     

    Signum egressus:

    4~20mA

    Capacitas Oneris Producti Permissa:

    0~500Ω (Configurabilis)

    Indicator LED:

    Viridis ⸺Indicator potentiae; lumen L1 accensum pro alarmi intervalli inferioris; lumen L2 accensum pro alarmi intervalli superioris.

    Accuratio exitus:

    Vide "Tabulam generis et ambitus signi ingressus".

    Tempus responsionis:

    300ms ad 90% valoris finalis

    Deviatio Temperaturae:

    0.005% FS/°C

    Parametri temperaturae:

    temperatura operandi -20℃~+60℃; temperatura repositionis -40℃~+80℃

    Humiditas relativa aeris:

    10%~95% RH sine condensatione

    Robur insulationis:

    extremum intrinsece tutum et extremum non intrinsece tutum (≥3000V AC/min); inter fontem potentiae et finem non intrinsece tutum (≥1500V AC/min)

    Resistentia insulationis:

    ≥100MΩ (inter input/output/power supply)

    Compatibilitas electromagnetica:

    secundum IEC 61326-1 (GB/T 18268), IEC 61326-3-1

    Tempus medium ad defectum:

    Decem milia horarum

    Requisita filorum:

    sectio transversalis ≥ 0.5mm2; robur insulationis ≥ 500V

    Instrumenta campi applicabilia:

    Termoresistens bifilaris vel trifilaris G53, Cu50, Pt100, Pt1000, Ni1000

    Locus institutionis:

    In zona tuta installatum, cum summis in locis periculosis Zonae 0, IIC, Zonae 20, IIIC instrumentorum intrinsece tutorum coniungi potest.

    Certificatio securitatis

    Corpus certificationis:

    Centrum Nationale Supervisionis et Probationis Qualitatis Productorum Electricorum Explosionibus Resistentium (CQST)

    Norma certificationis:

    GB/T 3836.1-22021, GB/T 3836.4-2021

    Symbolum explosionis immune:

    [Exia Ga]ⅡC, [Exia Da]ⅢC

    Parametri probati (inter terminales 1-2):

    Um: 250V AC/DC, Uo = 8.4V DC, Io = 31mA,
    Po = 65.1 W, Co = 4.8 μF, Lo = 20 mH.


    PHD-12HZ-X11



    Deprime_fasciculum