English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Dapetken Kutipen Instan .
Leave Your Message
PHC-11HF-14
H Seri Backplane Pemasangan Penghalang Keselamatan si Terisolasi .
Kategori Produk .
Produk si ipilih

PHC-11HF-14

Kontak ras tingkat logika masuken/saklar penggerak keluaren .
H Seri Backplane Pemasangan Penghalang Keselamatan si Terisolasi .
1 masuken 1 keluaren .

    Gambaren

    H seri pemasangan backplane terisolasi penghalang keselamaten i sisi operasi: PHC-11HF-14, masuken ras keluaren digital, masuken ras keluaren tunggal.

    Penghalang keselamaten banci mengubah kuantitas masuken saklar kontak ras tingkat logika i bas daerah keselamaten jadi kuantitas penggerak peralatan si aman secara intrinsik, ras keluarenna ku bidang daerah si berbahaya, seh maka banci mengendaliken katup solenoid, alarm terbegi ras teridah, rsd.

    Indikator status lit warna lampu merah ras kuning, sanga alarm maka lampu e merah, sanga ia ras katup solenoid keluaren, maka lampu e kuning.

    Produk enda perlu pasoken listrik si mandiri.

    Tegangan pasoken . 20~35VDC, pemaken daya
    Sinyal masuken . Ganti kontak, tingkat logika .
    Sinyal si ndarat Tegangan rangkaian terbuka> 24V, UE/IE=12,8V/48mA
    Fungsi inversi : K1 i aturken ku sisi “ON”, keluaren rangkaian ibalikken .
    Fungsi relay alarm . Saklar dial K2 i aturken ku sisi "ON", rangkaian mengadopsi fungsi alarm .
    Tahanan Beban10KΩ, alarm rangkaian terbuka (LB)
    Karakteristik keluaren relay alarm . 20ms, kapasitas penggerakna: 250VAC/2A, 30VDC/2A i bas beban resistif
    Jumlah si masuk ras si ndarat . 1 masuken 1 keluaren .
    Peralaten lapangan si berlaku . Katup solenoid keselamaten, alarm si terbegi ras si idah
    Parameter suhu . Suhu kerja: -20°C~+60°C, suhu penyimpanan: -40°C~+80°C
    Kelembapen si relatif 10% ~ 95% RH la lit kondensasi .
    Kekuatan dielektrik . Antara sisi si aman secara intrinsik ras sisi si la aman secara intrinsik (≥3000VAC/min); antara catu daya ras terminal si la aman secara intrinsik (≥1500VAC/menit)
    Ketahanen isolasi . ≥100MΩ (antara masuken/keluaren/pasoken listrik) .
    Ukuren Tebalna 15,8mm * belangna 104,8mm * ganjangna 116,1mm
    Kecocoken elektromagnetis . Menurut IEC 61326-1 (GB/T 18268), IEC 61326-3-1.
    Tanda si tahan ledaken . [Eksia Ga]IIC, [Eksia Da]IIIC
    Standar sertifikasi . 3836,1-2021, ras 3836,4-2021
    Badan si mereken sertifikasi . CQST (Pusat Pengawasan ras Uji Mutu Nasional Cina guna Produk Listrik si Ilindungi Ledaken)
    Parameter si enggo isertifikasi (antara terminal 2-1) . 147mA Po=0,92W Co=0,107μF Lo=1,5mH
    Persyaraten ingan pemasangan .

    Ipasang i bas zona aman, banci ihubungken ku alat keselamaten intrinsik i bas daerah si berbahaya seh ku Zona 0, IIC, Zona 20, ras IIIC .

    MTBF ≤100000 jam