English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Polihang Kutipan Instan
Leave Your Message
PHD-12TD-211
Input Analog
Kategori Produk
Produk Unggulan

PHD-12TD-211

PHD-12TD-211

Pemancar kalih utawi tiga kawat utawi sumber arus input /4~20mA output 1 input 2 output


Ringkesan

PHD-12TD-211 inggih punika penghalang keselamatan pamuput deteksi terisolasi sane kakaryanin khusus antuk input lan output analog.

    Ringkesan

    Input analog terisolasi penghalang pengaman antuk fungsi perlindungan gelombang ngicenin catu daya terisolasi antuk kalih - lan tiga pemancar kawat ring area sane berbahaya. Sinyal 4-20mA sane kapolihang olih pemancar utawi sumber arus punika katransmisiang saking area berbahaya nuju output area aman, antuk punika ngawinang beban ring area aman. Antuk kalih - utawi tiga pemancar kawat utawi sinyal sumber arus, penghalang keselamatan puniki mendukung komunikasi dua arah sinyal digital Hart sane katimpalin ring sinyal 4-20mA lan madue fungsi alarm pegat kawat.
    Produk puniki ngamerluang catu daya sane independen, antuk catu daya sane terisolasi, input, lan terminal output.

     

    1

     

    Input ring genah sané mabaya

    Sinyal input

    Pemancar kalih utawi tiga kawat utawi sumber arus (sinyal digital HART)

    Tegangan distribusi pemancar

    Tegangan rangkaian terbuka inggih punika ≤28V, lan tegangan output inggih punika ≥15,5V yening rangkaian punika 20mA.

    Output ring genah sané aman

    Sinyal sané medal

    4~20 mA (sinyal digital jantung)

    Beban output

    Ritatkala ngamedalang 20mA, 0~500 Ω (dados kasesuaiang)
    Jenis tegangan sane kamedalang opsional, daya tahan beban RL ≥ 330k Ω

    Parameter dasar

    Tegangan pasokan

    20~35VDC

    Konsumsi daya

    Rikala 24V catu daya, 20mA sane kamedalang
    ≤95mA(PHD-12TD-211+)

    Indikator LED

    Hijau: indikator daya

    Galah nyawis

    2ms mangda prasida nyujur 90% saking nilai pamuput

    Penyimpangan suhu

    0,005% FS/°C

    Parameter suhu

    Suhu makarya: -20°C ~ +60°C,
    Suhu genah nyimpen: -40°C ~ +80°C

    Kelembaban relatif

    10% ~ 95% RH nénten wénten kondensasi

    Kekuatan isolasi

    Pantaraning sisi aman intrinsik lan sisi sane nenten aman intrinsik (≥3000VAC/menit); pantaraning catu daya lan sisi sane nenten aman secara intrinsik (≥1500VAC/menit)

    Ketahanan isolasi

    ≥100MΩ (pantaraning input/output/pasokan daya)

    Kompatibilitas elektromagnetik

    Manut IEC 61326-1 (GB/T 18268), IEC 61326-3-1.

    MTBF

    100.000 jam

    Persyaratan kawat

    Panampangnyane ≥ 0,5mm2; Kekuatan isolasi ≥ 500V

    Piranti lapangan sane berlaku

    Kalih, sinyal pemancar tiga kawat (HART) utawi sumber arus (HART)

    Genah pamasangan

    Genah pemasangan: Kapasang ring zona aman, punika prasida kasambungang sareng instrumen keselamatan intrinsik ring genah sane berbahaya ngantos Zona 0, IIC, Zona 20, lan IIIC .

    Sertifikasi sané aman manut intrinsik

    Tanda bukti ledakan

    [Eks ia Ga]lIC [Eks ia Da]lllC

    Standar tahan ledakan

    GB/T3836,1-2021 GB/T3836,4-2021

    Terminal 3-2, 3-4:

    Um:250V AC/DC Uo=28V DC lo=93mA Po=0,65W Co=0,083μF Lo=4,2mH

    Terminal 1-2:

    Um:250V AC/DC Uo=7,2V DC lo=--- Po=-Co=12μF Lo=--

    Badan sertifikasi

    CQST(Pusat Pengawasan lan Uji Mutu Nasional Cina antuk Produk Listrik sane Kalindungin saking Ledakan)
    Pusat pengujian produk perlindungan kilat Shanghai