PHD-22TT-*1*1
Overview
Ing thermocouple input isolation safety barrier malyari yang mag-isolate ampo mag-convert kareng thermocouple (TC) signals kareng delikadung lugal keng 4-20mA current signals, ampo i-output nala keng safety zone. Ing safety barrier ayni atin yang built-in a cold junction compensation at malyari yang i-configure keng matalino. Ing tutuking range ning thermocouple malyari yang i-set kapamilatan ning computer software. Atin yang gagawan ing wire breakage alarm ampo out of range alarm. Ing produktung ayni mangailangan yang independenting power supply, a maki makabukud a power supply, input, ampo output terminals. Ing "*" mangabaldugan yang uri ning input ning thermocouple, at ing partikular a modelu mangabaldugan yang code (lawen ya ing "Input Signal Type and Range Table" para kareng detalye).
| Code | TC model | Sukat ning sukad | Minimum range | Katutuan ning pamagbayu |
| 1 | K | -200~1370°C | 50°C | 0.5°C/0.1% |
| 2 | S | -50~1760°C | 500°C | 1.5°C/0.1% |
| 3 | AMPONG | -140~1000°C | 50°C | 0.5°C/0.1% |
| 4 | J | -160~1200°C | 50°C | 0.5°C/0.1% |
| 5 | B | 250~1800°C | 500°C | 1.5°C/0.1% |
| 6 | T | -200~400°C | 50°C | 0.5°C/0.1% |
| 7 | R | -50~1760°C | 500°C | 1.5°C/0.1% |
| 8 | N | -200~1300°C | 50°C | 0.5°C/0.1% |
| Input keng mapanganib a lugal | |
| Input signal | K, S, E, J, B, T, R, N thermocouple signals (lawen ya ing "Input Signal Type and Range Table" para kareng detalye) |
| Input disconnection | Ing default a "low alarm" malyari yang i-modify keng "high alarm" kapamilatan ning configuration software |
| Signal range | Ing sukad ning thermocouple -10~100mV ya. |
| Sukat ning sukad | Deng gagamit gagawan da ing karelang sariling configuration neng mag-order la, at ipabalu da iti keng tail number o aliwa pa. |
| Built-in cold junction compensation | ±1°C(Compensation range -20°C~ +60°C) |
| Safety side output: | |
| Output signal | 4~20mA |
| Kapasidad ning karga | 0~500Ω(customizable) |
| Optional voltage output type, load resistance RL ≥ 330kΩ | |
| LED indicator | Green: Power indicator |
| Low range alarm yellow light on, high range alarm red light on | |
| Katuliran ning pamaglual | Paki-refer me ing "Input Signal Type and Range Table" para kareng detalye |
| oras ning pakibat | miras keng 90% ning tauling ulaga kilub ning 500ms |
| Ing pamagbayu ning temperatura | 0.005%FS/°C |
| Parameters ning temperatura | Temperatura ning obra: -20°C~+60°C, temperatura ning pamitipun:-40°C~+80°C |
| Relatibung humidity | 10%~95% RH alang condensation |
| Dielectric strength | pilatan ning intrinsically safe side ampo non-intrinsically safe side (≥ 3000VAC/min); |
| pilatan ning suplay ning kuryenti ampo ing e ligtas a terminal (≥ 1500VAC/min) | |
| Insulation resistance | ≥100MΩ (pilatan ning input/output/power supply) |
| Electromagnetic compatibility | Agpang keng IEC 61326-1(GB/T 18268), IEC 61326-3-1 |
| MTBF | 100000h |
| kailangan ing kawad | Horizontal cutting surface ≥ 0.5mm2; Insulation strength ≥ 500V |
| Applicable field equipments | K. S, E, J, B, T, R, N TC sensors |
| Lugar ning pamag-install | Maka-install ya keng safe zone, malyari yang ikonekta kareng intrinsic safety instruments kareng hazardous a lugal angga keng Zone 0, IIC, Zone 20, ampo IIIC |
| Sertipikasyun ning kaligtasan | |
| Sertipikasyun ning kaligtasan a pang-obra | SIL2 agpang keng IEC 61508 standards |
| Markang e malyaring sabog | [Ex ia Ga]lIC [Ex ia Da]lllC |
| Pamantayan a e makasabog | GB/T3836.1-2021 GB/T3836.4-2021 |
| Terminals 1-2, 3-4: | Um:250V AC/DC Uo=8.4V DC Io=31mA |
| Po=65.1mW Co=4.8μF Lo=20mH | |
| katawan ning sertipikasyun | CQST(China National Quality Supervision and Test Center for Explosion Protected Electrical Products) |