Luxembou..
English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Kritt direkt en Devis
Leave Your Message
PHD-12TZ-466+
Temperatureingang
Produktkategorien
Ausgewielte Produkter

PHD-12TZ-466+

Iwwerspannungsschutztyp RTD-Input isoléiert Sécherheetsbarriär

1 Input 2 Outputs

Input: Zwee-Drot oder Dräi-Drot RTD Pt100 Signal

Ausgang: RTD Pt100 Signal

    Iwwersiicht

    D'Sécherheetsbarriär fir den Thermistor-Input mat Iwwerlaaschtungsschutzfunktioun kann d'Pt100-Signaler vun Zwei- an Dräi-Drot-Thermistoren (RTDs) a geféierleche Beräicher an en 1:1-Signal vum Thermistor ëmwandelen an an d'Sécherheetszon weiderginn. Si kann intelligent konfiguréiert ginn, an den aktuellen Beräich vum thermesche Widderstand kann iwwer Computersoftware agestallt ginn. Si huet d'Funktioune vun engem Drotbrochalarm an engem Alarm fir ausserhalb vum Beräich. Dëst Produkt erfuerdert eng onofhängeg Stroumversuergung, mat isoléierter Stroumversuergung, Input- an Output-Terminaler.

     

    1

     

    Input
    Inputsignal Zwee- oder dräi-Drot Pt100 Signal
    Miessberäich -150℃~ 850℃
    Ausgab:
    Ausgangssignal RTD Pt100 Signal
    Funktiounen vum Iwwerspannungsschutz:
    Nennenentladungsstroum ln(8/20μs) 5 kA ze
    Spannungsschutzniveau erop (8/20μs): 60V (Linn zu Linn)
    Spannungsschutzniveau erop (8/20μs): 600V (Linn bis Mass)
    No de Standarden GB/T18802.21-2016 (gläichwäerteg mat 1EC61643-21:2012)
    Versuergungsspannung 20-35VDC
    Stroumverbrauch ≤55mA (wann 24VDC Stroumversuergung)
    LED-Indikator Gréng: Stroumindikator
    Kuerzschlussalarm: D'rout Luucht vun der ALM bleift laang un
    Alarm fir oppent Circuit: ALM rout Luucht blénkt
    Ausgangsgenauegkeet 0,1% FS
    Temperaturdrift 0,1% FS/10 ℃
    Temperaturparameter Aarbechtstemperatur: -20℃~+60℃, Lagertemperatur: -40℃~+80℃
    Relativ Loftfiichtegkeet 10%~95% RH keng Kondensatioun
    Isolatiounsstäerkt ≥2000VAC/min Zwëschen der intrinsesch sécherer Säit an der net intrinsesch sécherer Säit (≥3000VAC/min); tëscht der Stroumversuergung an der net intrinsesch sécherer Säit (≥1500VAC/min)
    Isolatiounswiderstand ≥100MΩ (tëscht Input/Output/Stroumversuergung)
    Elektromagnetesch Kompatibilitéit Geméiss IEC 61326-1 (GB/T 18268), IEC 61326-3-1
    MTBF 800000 Stonnen
    Ufuerderunge fir den Drot Querschnitt ≥ 0,5 mm²; Isolatiounsstäerkt ≥ 500 V
    Uwendbar Feldausrüstung Zwee- oder dräi-Drot-RTD Pt100



    1

    Bemierkung: 1. D'Power Rail-Funktioun ass eng optional Funktioun, an d'Benotzer mussen spezifizéieren
    d'Method vun der Stroumversuergung beim Bestellung
    D'Auswiel vun de Stroumleitungsschinneverbinder kann op Säit 89 vum "Annex" verweisen.
    2. Beim Aféierung vun engem Dräi-Drot-RTD ass et néideg sécherzestellen, datt déi dräi
    D'Drot sinn esou vill wéi méiglech vun der selwechter Längt
    3. Beim Aféierung vun engem Zweidrot-RTD mussen d'Sécherheetsbarrièreklemmen 6 an 5
    kuerzgeschloss
    1



    Datei_eroflueden
    PHD-11TC-33A-23


    Datei_eroflueden
    PHD-12TZ-466+