Frisian
English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Krij direkte offerte
Leave Your Message
PHD-12TZ-466+
Temperatuerynfier
Produktkategoryen
Featured Produkten

PHD-12TZ-466+

Overspanningsbeskermingstype RTD-ynfier isolearre feiligensbarriêre

1 ynfier 2 útfier

Ynfier: Twa-trieds of trije-trieds RTD Pt100-sinjaal

Utfier: RTD Pt100-sinjaal

    Oersicht

    De termistor-yngongsisolaasjefeiligensbarriêre mei oerspanningsbeskermingsfunksje kin de Pt100-sinjalen fan twa- en trije-trieds termistors (RTD's) yn gefaarlike gebieten omsette yn in 1:1-sinjaal fan 'e termistor en it nei de feiligenssône stjoere. It kin yntelligint konfigurearre wurde, en it werklike berik fan 'e termyske wjerstân kin ynsteld wurde fia kompjûtersoftware. It hat de funksjes fan triedbreukalarm en bûten-berikalarm. Dit produkt fereasket in ûnôfhinklike stroomfoarsjenning, mei isolearre stroomfoarsjenning, ynfier- en útfierterminals.

     

    1

     

    Ynfier
    Ynfiersignaal Twa-trieds of trije-trieds Pt100-sinjaal
    Mjitberik -150℃~ 850℃
    Utfier:
    Utfiersignaal RTD Pt100-sinjaal
    Funksjes fan oerspanningsbeskerming:
    Nominale ûntladingsstroom ln (8/20μs) 5 kA
    Spanningsbeskermingsnivo omheech (8/20μs): 60V (line nei line)
    Spanningsbeskermingsnivo omheech (8/20μs): 600V (line nei grûn)
    Neffens noarmen GB/T18802.21-2016 (lykweardich oan 1EC61643-21:2012)
    Oanfierspanning 20-35VDC
    Enerzjyferbrûk ≤55mA (as 24VDC stroomfoarsjenning)
    LED-yndikator Grien: Stroomindikator
    Koartslutingalarm: ALM read ljocht bliuwt lang oan
    Iepen sirkwyalarm: ALM read ljocht knippert
    Útfierkrektens 0,1%FS
    Temperatuerdrift 0,1% FS/10 ℃
    Temperatuerparameters Wurktemperatuer: -20℃~+60℃, opslachtemperatuer: -40℃~+80℃
    Relative fochtigens 10% ~ 95% RH gjin kondensaasje
    Isolaasjesterkte ≥2000VAC/min Tusken yntrinsyk feilige kant en net-yntrinsyk feilige kant (≥3000VAC/min); tusken stroomfoarsjenning en net-yntrinsyk feilige kant (≥1500VAC/min)
    Isolaasjeresistinsje ≥100MΩ (tusken ynfier/útfier/stroomfoarsjenning)
    Elektromagnetyske kompatibiliteit Neffens IEC 61326-1 (GB/T 18268), IEC 61326-3-1
    MTBF 800000 oeren
    Triedeasken Dwersdoorsnede ≥ 0.5mm2; Isolaasjesterkte ≥ 500V
    Tapasselike fjildapparatuer Twa-trieds of trije-trieds RTD Pt100



    1

    Opmerking: 1. De power rail-funksje is in opsjonele funksje, en brûkers moatte spesifisearje
    de metoade foar stroomfoarsjenning by it pleatsen fan in bestelling
    De seleksje fan stroomrailferbiningen kin ferwize nei side 89 fan 'e "Bylage"
    2. By it ynfieren fan in trijetriedige RTD is it needsaaklik om te soargjen dat de trije
    triedden binne safolle mooglik fan gelikense lingte
    3. By it ynfieren fan in twa-trieds RTD moatte de feilichheidsbarriêreterminals 6 en 5
    koartsluting
    1



    Triem_downloade
    PHD-11TC-33A-23


    Triem_downloade
    PHD-12TZ-466+