Croatian
English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Zatražite trenutnu ponudu
Leave Your Message
PHD-12TZ-466+
Ulaz temperature
Kategorije proizvoda
Istaknuti proizvodi

PHD-12TZ-466+

Zaštita od prenapona Vrsta RTD ulaz izolirana sigurnosna barijera

1 ulaz 2 izlaza

Ulaz: Dvožični ili trožični RTD Pt100 signal

Izlaz: RTD Pt100 signal

    Pregled

    Sigurnosna barijera za izolaciju ulaza termistora s funkcijom prenaponske zaštite može pretvoriti Pt100 signale dvožičnih i trožičnih termistora (RTD) u opasnim područjima u 1:1 signal termistora i prenijeti ga u sigurnosnu zonu. Može se inteligentno konfigurirati, a stvarni raspon toplinskog otpora može se postaviti putem računalnog softvera. Ima funkcije alarma za prekid žice i alarma izvan raspona. Ovaj proizvod zahtijeva neovisno napajanje, s izoliranim napajanjem, ulaznim i izlaznim priključcima.

     

    1

     

    Ulazni
    Ulazni signal Dvožični ili trožični Pt100 signal
    Raspon mjerenja -150℃~ 850℃
    Izlaz:
    Izlazni signal RTD Pt100 signal
    Značajke zaštite od prenapona:
    Nazivna struja pražnjenja ln (8/20 μs) 5kA
    Razina naponske zaštite Up (8/20 μs): 60 V (linija-linija)
    Razina naponske zaštite Up (8/20 μs): 600 V (linija prema uzemljenju)
    Prema standardima GB/T18802.21-2016 (ekvivalent 1EC61643-21:2012)
    Napon napajanja 20-35 VDC
    Potrošnja energije ≤55mA (pri napajanju od 24VDC)
    LED indikator Zelena: Indikator napajanja
    Alarm kratkog spoja: Crveno svjetlo ALM ostaje upaljeno dugo vremena
    Alarm otvorenog strujnog kruga: treperi crveno svjetlo ALM
    Točnost izlaza 0,1%FS
    Temperaturni pomak 0,1%FS/10℃
    Temperaturni parametri Radna temperatura: -20℃~+60℃, temperatura skladištenja: -40℃~+80℃
    Relativna vlažnost 10%~95% relativne vlažnosti bez kondenzacije
    Čvrstoća izolacije ≥2000 VAC/min Između intrinzično sigurne i neintrinzično sigurne strane (≥3000 VAC/min); između napajanja i neintrinzično sigurne strane (≥1500 VAC/min)
    Otpor izolacije ≥100MΩ (između ulaza/izlaza/napajanja)
    Elektromagnetska kompatibilnost Prema IEC 61326-1 (GB/T 18268), IEC 61326-3-1
    MTBF (srednji gubitak između godina) 800000 sati
    Zahtjevi za žice Presjek ≥ 0,5 mm2; Čvrstoća izolacije ≥ 500 V
    Primjenjiva terenska oprema Dvožični ili trožični RTD Pt100



    1

    Napomena: 1. Funkcija napojne šine je opcionalna funkcija i korisnici je trebaju navesti
    način napajanja prilikom narudžbe
    Odabir konektora za energetske šine možete pronaći na stranici 89 "Dodatka".
    2. Prilikom unosa trožičnog RTD-a, potrebno je osigurati da su tri
    žice su što je moguće jednake duljine
    3. Prilikom spajanja dvožilnog RTD-a, terminali 6 i 5 sigurnosne barijere moraju biti
    kratko spojen
    1



    Preuzimanje_datoteke
    PHD-11TC-33A-23


    Preuzimanje_datoteke
    PHD-12TZ-466+