Indonesian
English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Dapatkan Penawaran Harga Instan
Leave Your Message
PHD-11TT-*8+
Masukan suhu
Kategori Produk
Produk Unggulan

PHD-11TT-*8+

Penghalang keselamatan terisolasi input TC

1 masukan 1 keluaran

Input: Sinyal TC

Output: Sinyal 1:1 millivolt

    Ringkasan

    Penghalang pengaman isolasi input termokopel dengan fungsi proteksi lonjakan tegangan dapat mengirimkan sinyal millivolt dari termokopel (TC) di area berbahaya ke area aman dengan perbandingan 1:1. Produk ini memerlukan catu daya independen, dengan catu daya, input, dan terminal output yang terisolasi.

    Jenis sinyal masukan dan rentang pengukuran
    Kode Model TC Rentang pengukuran Rentang minimum Akurasi konversi
    1 K -200~1370℃ 50℃ 0,5℃/0,1%
    2 S -50~1760℃ 500℃ 1,5℃/0,1%
    3 DAN -140~1000℃ 50℃ 0,5℃/0,1%
    4 J -160~1200℃ 50℃ 0,5℃/0,1%
    5 B 250~1800℃ 500℃ 1,5℃/0,1%
    6 T -200~400℃ 50℃ 0,5℃/0,1%
    7 R -50~1760℃ 500℃ 1,5℃/0,1%
    8 N -200~1300℃ 50℃ 0,5℃/0,1%

     

    1

     

    Masukan
    Sinyal masukan Sinyal termokopel K, S, E, J, B, T, R, N (lihat "Tabel Jenis dan Rentang Sinyal Masukan" untuk detailnya)
    Jangkauan sinyal -20~80mV
    Keluaran sisi keselamatan:
    Sinyal keluaran Termokopel 1:1
    Fitur perlindungan lonjakan arus:
    Arus pelepasan nominal ln(8/20μs) 5kA
    Tingkat perlindungan tegangan Naik (8/20μs): 60V (antar fasa)
    Tingkat perlindungan tegangan Naik (8/20μs): 600V (tegangan fasa ke tanah)
    Sesuai standar GB/T18802.21-2016 (setara dengan 1EC61643-21:2012)
    Konsumsi daya ≤40mA (Saat menggunakan catu daya 24V)
    Indikator LED Hijau: Indikator daya
    Akurasi keluaran Silakan lihat "Tabel Tipe dan Rentang Sinyal Input" untuk detailnya.
    Waktu respons Mencapai 90% dari nilai akhir dalam waktu 300ms
    Pergeseran suhu 0,005%FS/℃
    Parameter suhu Suhu kerja: -20℃~+60℃, suhu penyimpanan: -40℃~+80℃
    Kelembaban relatif Kelembapan relatif 10%~95% tanpa kondensasi
    Kekuatan isolasi
    Antara sisi yang aman secara intrinsik dan sisi yang tidak aman secara intrinsik (≥3000VAC/menit); antara catu daya dan sisi yang tidak aman secara intrinsik (≥1500VAC/menit)
    Resistansi isolasi ≥100MΩ (antara input/output/catu daya)
    Kompatibilitas elektromagnetik Menurut IEC 61326-1(GB/T 18268), IEC 61326-3-1
    MTBF 80000 jam
    Persyaratan kabel Ketebalan dinding ≥ 0,5mm²; Kekuatan isolasi ≥ 500V
    Peralatan lapangan yang berlaku Sensor K, S, E, J, B, T, R, N TC
    Tempat pemasangan Jika dipasang di zona aman, alat ini dapat dihubungkan ke instrumen keselamatan intrinsik di area berbahaya hingga Zona 0, IIC, Zona 20, dan IIIC.



    1

    Catatan: Fungsi power rail adalah fungsi opsional, dan pengguna perlu menentukannya.
    metode catu daya saat melakukan pemesanan
    Pemilihan konektor rel daya dapat merujuk ke halaman 89 dari "Lampiran".



    Unduh_file
    PHD-11TC-33A-23


    Unduh_file
    PHD-11TT-X8+