Batak Karo
English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Dapetken Kutipen Instan .
Leave Your Message
PHD-11TT-*8+
Suhu si masuk .
Kategori Produk .
Produk si ipilih

PHD-11TT-*8+

TC masuken terisolasi penghalang keselamaten .

1 masuken 1 keluaren .

Masuk :Sinyal TC .

Keluarenna : 1:1 sinyal milivolt .

    Gambaren

    Penghalang keselamaten isolasi masuken termokop alu fungsi perlindungen gelombang banci mentransmisiken sinyal milivolt ibas termokop (TC) ibas daerah si berbahaya ku daerah si aman ibas 1: 1. Produk enda membutuhken pasoken listrik si mandiri, alu terminal pasoken listrik, masuk, ras keluar si terisolasi.

    Jenis sinyal masuk ras rentang pengukuren .
    Kode Model TC . Rentang pengukuren . Kisaran si minim Akurasi konversi .
    1 K . -200~1370°C 50°C 0,5°C/0,1%
    2 S . -50~1760°C 500°C 1,5°C/0,1%
    3 RAS -140~1000°C 50°C 0,5°C/0,1%
    4 J . -160~1200°C 50°C 0,5°C/0,1%
    5 B . 250~1800°C 500°C 1,5°C/0,1%
    6 T . -200~400°C 50°C 0,5°C/0,1%
    7 . R . -50~1760°C 500°C 1,5°C/0,1%
    8 . N . -200~1300°C 50°C 0,5°C/0,1%

     

    1

     

    Masuken .
    Sinyal masuken . Sinyal termokop K, S, E, J, B, T, R, N (nen "Tabel Jenis ras Rentang Sinyal Masuken" guna lebih jelasna)
    Rentang sinyal -20 ~ 80 mV
    Keluaren sisi keselamaten:
    Sinyal si ndarat Termokop 1: 1 .
    Fitur perlindungen gelombang:
    Arus debit nominal ln (8/20 μs) 5kA
    Tingkat perlindungen tegangan Naik (8/20μs): 60V(garis ku garis)
    Tingkat perlindungen tegangan Naik (8/20μs): 600V(garis ku taneh)
    Rikutken patoken . GB/T18802.21.2016 (setara ras 1EC61643-21.2012)
    Konsumsi daya . ≤40mA(Adi 24V listrik)
    Indikator LED . Hijau: Indikator daya .
    Akurasi keluaren . Banci idahndu "Tabel Jenis ras Rentang Sinyal Masuken" guna meteh terbuen
    Waktu tanggapen . Mencapai 90% nilai akhir ibas waktu 300ms .
    Suhu si ergeser . 0,005% FS/°C
    Parameter suhu . Suhu kerja: -20°C~+60°C, suhu penyimpanan:-40°C~+80°C
    Kelembapen si relatif 10% ~ 95% RH la lit kondensasi .
    Kekuatan isolasi .
    Antara sisi si aman secara intrinsik ras sisi si la aman secara intrinsik (≥3000VAC/min); antara pasoken listrik ras sisi si la aman secara intrinsik (≥1500VAC/menit)
    Ketahanen isolasi . ≥100MΩ (antara masuken/keluaren/pasoken listrik) .
    Kecocoken elektromagnetis . Menurut IEC 61326-1(GB/T 18268), IEC 61326-3-1.
    MTBF 80000 jam
    Persyaraten kawat . Silang ≥ 0,5mm2; Kekuatan inskulasi ≥ 500V .
    Peralaten lapangan si berlaku . K. S, E, J, B, T, R, N Sensor TC
    Ingan pemasangan . Ipasang i bas zona aman, banci ihubungken ku alat keselamaten intrinsik i bas daerah si berbahaya seh ku Zona 0, IIC, Zona 20, ras IIIC .



    1

    Cataten: Fungsi power rail eme fungsi si la perlu, janah pengguna perlu nentuken .
    cara pasoken listrik sanga erbahan pesanen .
    Pemilihen penghubung rel daya banci idahndu i bas halamen 89 “Lampiren”.



    Unduh_berkas
    PHD-11TC-33A-23


    Unduh_berkas
    PHD-11TT-X8+