English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
立即取得報價
Leave Your Message
PHD-12TT-*11
溫度輸入
產品類別
特色產品

PHD-12TT-*11

PHD-12TT-*11

TC輸入/4-20mA輸出(可設定)1個輸入 2個輸出


概述

隔離式安全屏障:PHD-12TT-*11,熱電偶訊號輸入,1 個輸入和 2 個輸出。

    概述

    熱電偶輸入隔離安全屏障可將危險區域內的熱電偶 (TC) 訊號隔離並轉換為 4-20mA 電流訊號,並輸出至安全區域。此安全屏障內建冷端補償功能,並可進行智慧配置。熱電偶的實際量程可透過電腦軟體設定。它具有斷線警報和超量程警報功能。本產品需獨立電源,並採用隔離式電源、輸入及輸出端子。 「*」表示熱電偶的輸入類型,特定型號以代碼表示(詳情請參閱「輸入訊號類型和量程表」)。

    輸入訊號類型和測量範圍

    程式碼

    TC模型

    測量範圍

    最小射程

    轉換精度

    1

    K

    -200~1370

    50

    0.5/0.1%

    2

    S

    -50~1760

    500

    1.5/0.1%

    3

    -140~1000

    50

    0.5/0.1%

    4

    J

    -160~1200

    50

    0.5/0.1%

    5

    B

    250~1800

    500

    1.5/0.1%

    6

    T

    -200~400

    50

    0.5/0.1%

    7

    -50~1760

    500

    1.5/0.1%

    8

    N

    -200~1300

    50

    0.5/0.1%

     

     

    規格

     

    危險區域的輸入

     

    輸入訊號

    K、S、E、J、B、T、R、N 熱電偶訊號(詳情請參閱「輸入訊號類型和範圍表」)

    輸入斷開

    預設的“低警報”可以透過設定軟體修改為“高警報”。

    訊號範圍

    對應熱電偶的測量範圍為-10~100mV。

    測量範圍

    使用者在訂購時自行進行配置,並在尾號或其他地點註明。

    內建冷端補償

    ±1°C(補償範圍 -20°C~ +60°C)

    安全側輸出:

     

    輸出訊號

    4~20mA

    輸出負載能力

    0~500Ω(可自訂)
    可選電壓輸出類型,負載電阻 RL ≥ 330kΩ

    電源

    20-35VDC

    耗電量

    24VDC電源,20mA輸出
    ≤40mA(PHD-11TT-*1)
    ≤70mA(PHD-12TT-*11)

    LED指示燈

    綠色:電源指示燈
    低量程警報 L1 指示燈亮,高量程警報 L2 指示燈亮

    輸出精度

    詳情請參閱「輸入訊號類型和範圍表」。

    回應時間

    在 500 毫秒內達到最終值的 90%。

    溫度漂移

    0.005%FS/℃

    溫度參數

    工作溫度:-20℃~+60℃,儲存溫度:-40℃~+80℃

    相對濕度

    相對濕度10%~95% 無冷凝

    介電強度

    本質安全側與非本質安全側之間(≥ 3000VAC/min);
    電源與非本質安全端子之間(≥ 1500VAC/min)

    絕緣電阻

    ≥100MΩ(輸入/輸出/電源之間)

    電磁相容性

    根據 IEC 61326-1(GB/T 18268)、IEC 61326-3-1

    平均故障間隔時間

    100000小時

    電線要求

    橫截面積≥0.5mm²;絕緣強度≥500V

    適用現場設備

    K. S、E、J、B、T、R、N TC感測器

    安裝位置

    安裝在安全區域內,它可以連接到危險區域(最高可達 0 區、IIC 區、20 區和 IIIC 區)的本質安全型儀表。

    安全認證

    功能安全認證

    符合IEC 61508標準的SIL2

    防爆標誌

    [Ex ia Ga] IIC [Ex ia Da] ⅢC

    防爆標準

    GB/T 3836.1-2021 GB/T 3836.4-2021

    3-4號航廈:

    單位:250V AC/DC Uo=8.4V DC Io=31mA
    Po=65.1mW Co=4.8μF Lo=20mH

    認證機構:

    中國防爆電氣產品國家品質監督檢驗中心(CQST)


    PHD-11TT-X1 PHD-12TT-X11

    註:1. PHD-11TT - * 1 不包含輸出部分 2
    2. 電源軌功能為選購功能,使用者下單時需指定供電方式。
    電源軌連接器的選擇可參考「附件」第 89 頁。