Cantonese
English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
攞即時報價
Leave Your Message
PHG-12TZ-466 +
浪涌保護型信號隔離器
產品類別
精選產品

PHG-12TZ-466 +

浪涌保護型 RTD 輸入溫度轉換器

PHG-12TZ-466 + 1 輸入 2 輸出

輸入:兩線或三線 RTD Pt100訊號

輸出: RTD Pt100訊號

    概覽

    熱敏電阻輸入溫度轉換器具有浪涌保護功能,可以將兩線同三線熱敏電阻( RTD )嘅 Pt100訊號轉換成熱敏電阻嘅1:1訊號。佢可以智能配置,而且熱阻嘅實際範圍可以透過電腦軟件設定。
    本產品需要獨立電源,有隔離電源、輸入、輸出端子。

    規格

    輸入
    輸入訊號 兩線或三線 Pt100訊號
    測量範圍 -150 ° C - 850 ° C
    輸出:
    輸出訊號 RTD Pt100訊號
    負載能力 負載能力 0-500 Ω (可自訂)
    浪涌保護功能:
    標稱放電電流 ln ( 8 / 20 μ s ) 5kA
    電壓保護等級上升( 8 / 20 μ s ): 60V (線對線)
    電壓保護等級上升( 8 / 20 μ s ): 600V (線對地)
    根據標準 GB/T18802.21-2016(相當於1EC61643-21:2012)
    電源電壓 20-35伏直流電
    功耗
    LED 指示燈 綠色:電源指示燈
    短路警報: ALM 紅燈長時間亮起
    開路警報: ALM 紅燈閃爍
    輸出準確度 0.1 % FS
    溫度漂移 0.1 % FS/10 ° C
    溫度參數 工作溫度: -20 ° C ~ + 60 ° C ,儲存溫度: -40 ° C ~ + 80 ° C
    相對濕度 10 % ~ 95 % RH 冇結露
    絕緣強度 ≥ 2000VAC / 分鐘(輸入 / 輸出 / 電源之間)
    絕緣電阻 ≥ 100M Ω (輸入 / 輸出 / 電源之間)
    電磁兼容性 根據 IEC 61326-1( GB/T 18268), IEC 61326-3-1
    MTBF 800000h
    電線要求 橫截面 ≥ 0.5mm2;絕緣強度 ≥ 500V
    適用嘅現場設備 兩線或三線 RTD Pt100

    尺寸

    PHG-12TZ-466+ . jpg

    示意圖

    PHG-12TZ-466+(3)。 jpg

    筆記薄:

    1. 電源軌功能為選配功能,用戶下單時需要指定供電方式

    電源軌連接器嘅選擇可以參考「附件」嘅第89頁。

    2. 輸入三線 RTD 時,必須盡量確保三線長度相等

    3. 輸入兩線 RTD 時,安全屏障端子5同6必須短路

    PHG-12TZ-466+(2)。 jpg