- Terminal Board
- Makabukud a Safety Barriers
- Signal Isolators
- Surge Protective Devices
- Safety Relays
- Isolated Intelligent I/O Modules
- Intelligent Gateways
- Industrial Data Optical Transceivers
- Online Dew Point Analyzers
- Data Acquisition Modules
- HART data converter
PH6004-1AR1B
Overview
Ing PH6004-1AR1B-F metung yang safety relay control module a masanting para keng DO signal isolation ampo conversion keng SIS systems. Atin yang 1 normally open (NO) contact ampo 1 normally closed (NC) contact, ampo atin yang reserved terminals para keng mabilis a offline Proof Test testing. Ing fuse compartment keng panel maka-install ya keng 5A fuse protection, para kareng gagamit mabilis lang palitan deng mesira nang fuse. Ing internal circuit gagamit yang Fail-safe technology, triple redundancy technology, ampo contact fusion protection technology.
Technical data
| Power data: | |
| Suplay ning kuryenti: | 16~35V DC |
| Kasalukuyan a pamangailangan: | ≤60mA (24V DC) |
| Input data: | |
| Bilang da reng kanal | 1 |
| Input current: | ≤60mA (24V DC) |
| Cable resistance: | ≤ 15 Ω |
| Input device: | SIS controller DI/DO signals |
| Output data: | |
| Bilang da reng akasabi: | 1NO+1NC |
| Materyal a gamitan: | Ag-alloy |
| Proteksyun keng fuse: | 5A (Internal) |
| Kategorya ning pamangamit: | 5A/250V AC; 5A/24V DC |
| Data ning oras: | |
| Switch-on delay : | ≤ 30ms |
| Delay-on de-energisation: | ≤30ms |
| Oras ning pamagbawi: | ≤ 30ms |
| Magsupply short interruption: | 20ms |
| sertipikasyun ning kaligtasan | |
| Antas ning Pamagganap (PL) | PLe conform keng EN ISO 13849 |
| Security Category (Cat.) | Cat.4 conform keng EN ISO 13849 |
| Oras ning Gawa (TM) | 20 banua makayagpang ya keng EN ISO 13849 |
| Diagnostic coverage (DC/DCavg) | 99% makatuglung la keng EN ISO 13849 |
| Safety Integrity Level (SIL) | SIL3 conform ya keng IEC 61508,IEC 62061 |
| Hardware Fault Tolerance (HFT) | 1 conform keng IEC 61508,IEC 62061 |
| Safe failure fraction(SFF) | 99% makayagpang la keng IEC 61508,IEC 62061 |
| Probability ning hazardous failure (PFHd) | 3.09E-10/h conform keng IEC 61508,IEC 62061 |
| StopCategory | 0 makayagpang ya keng EN 60204-1 |
| 10% average a bilang da reng hazardous failure cycles da reng components (B10d) | |
| DC13,Ue=24V | Ie 5A 2A 1A Cycles 300,000 2,000,000 7,000,000 |
| AC15,Ue=230V | Ie 5A 2A 1A Cycles 200,000 230,000 380,000 |
| Katangian ning kapaligiran | |
| Electromagnetic compatibility | conforms to EN 60947, EN 61000-6-2, EN 61000-6-4 |
| Vibration frequency | 10Hz~55Hz |
| Vibration amplitude | 0.35mm |
| temperatura ning paligid | -20 °C~+60 °C |
| temperatura ning pamitipun | -40 ℃~+85 ℃ |
| Relatibung humidity | 10% anggang 90% |
| katangian ning insulation | |
| Electrical clearance ampo creepage distance | conform keng EN 60947-1 |
| Antas ning sobrang boltahe | III |
| Antas ning polusyun | 2 |
| Antas ning proteksyun | IP20 |
| Lakas ning insulasyon | 1500V AC, 1 minutu |
| Rated insulation voltage | 250V AC |
| Rated impulse voltage | 6000V(1.2/50us) |
Panlual a sukad

Functional Block Diagram

tipikal a aplikasyun

Wiring diagram
(1) Ing instrument wiring mag adopt yang Pluggable connecting terminal ;
(2) Ing malambut a tansu a cross-sectional area ning input side wire dapat mas maragul ya kesa 0.5mm2, at ing output side dapat mas maragul ya kesa 1mm2;
(3) Ing makabuklat a kaba ning kawad mga 8mm ya, na makakandadu kareng M3 screws;
(4) Deng output contacts kailangan lang mamye sapat a fuse protection connections;
(5) Ing copper conductor dapat makayabut ya keng temperaturang e kumulang keng 75 °C;
(6) Deng terminal screws malyari lang maging sangkan ning misoperation, pamangisnawa, atbp. Uli na niti, pakihigpitan me agpang keng makasulat a torque. Terminal screw tightening torque 0.5Nm.

Install
Deng safety relays dapat lang i-install kareng control cabinets na ating at least IP54 protection level.
Ing PH6005-1AR1B-F series safety relays maka-install la ngan kareng DIN35mm guide rails. Deng steps ning pamag install ilapin deng makatuki
(1) I-clamp ing babo nang dake ning instrumentu keng guide rail;
(2) Itulak me ing lalam nang dake ning instrumentu keng guide rail.

Pamaglako
Isulud me ing screwdriver (blade width ≤ 6mm) keng metal a latch keng lalam ning instrument panel;
Iyugse me ing distornilyador patas at iyugse me ing metal a kandado pababa;
Iyugse me ing instrument panel patas at palual keng guide rail.

Ayusan
(1) Paki-check regular nung ing safety function ning safety relay atyu ya keng masanting a kondisyun, ampo nung atin yang tanda na ing circuit o ing original me-tamper ya o me-bypass ya;
(2) Paki tukian la reng kaugnayan a regulasyun ning kaligtasan at mag operate agpang kareng instruksiun na niting instruction manual, nung ali malyari yang magdalang makamate a aksidenti o pangawala da reng tau at pibandian;
(3) Ding produktu dinalan lang mahigpit a pamagsuri at pamagkontrol king kalidad bayu la meko king pabrika. nung akit mu na ali la gagana deng produktu ampo magduda kang atin yang depektu ing internal module, pakisabi me ing pekamalapit a ahente o diretsu kang makipag ugnayan keng technical support hotline.
(4) Kilub ning anam a banua manibat keng petsa ning pamagdeliver, ding sablang problema keng kalidad ning produktu keng normal a pamangamit dapat yang ayusan ning Pinghe alang bayad.
Atensyun
Paki-verify nung ing packaging ning produktu, ing modelu ning label ning produktu, ampo reng specifications makayagpang la keng kontrata ning pamamili;
Bayu me i-install at gamitan ing safety relays, basa meng masalese ining manual;
nung atin kang kutang, pakisabi me ing Beijing Pinghe Technical Support Hotline keng 400 711 6763;
Ing safety relay dapat yang i-install keng control cabinet na atin at least IP54 protection level;
Ing instrumentu atin yang 24V power supply, ampo ing pamangamit 220V AC power supply mahigpit yang bawal;