English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Kritt direkt en Devis
Leave Your Message
PH6004-1AR1B
Sécherheetsrelais vum SIS-System
Produktkategorien
Ausgewielte Produkter

PH6004-1AR1B

Uwendung am SIS-Controller DO-Signaleinput

    Iwwersiicht

    Den PH6004-1AR1B-F ass e Sécherheetsrelais-Kontrollmodul, dee fir d'DO-Signalisolatioun an d'Konversioun a SIS-Systemer gëeegent ass. En huet 1 normalerweis oppene (NO) Kontakt an 1 normalerweis zouene (NC) Kontakt, mat reservéierten Terminaler fir séier Offline-Proof-Test-Tester. De Sicherungsfach um Panel ass mat engem 5A-Sicherungsschutz virinstalléiert, sou datt d'Benotzer beschiedegt Sicherungen séier ersetzen kënnen. Den internen Circuit benotzt Fail-Safe-Technologie, Triple Redundance-Technologie a Kontaktfusiounsschutztechnologie.

    Technesch Donnéeën

    Leeschtungsdaten:
    Stroumversuergung: 16~35V Gläichstroum
    Stroumverbrauch: ≤60mA (24V Gläichstroum)
    Inputdaten:
    Zuel vun de Kanäl 1
    Inputstroum: ≤60mA (24V Gläichstroum)
    Kabelwiderstand: ≤ 15 Ω
    Input-Apparat: DI/DO Signaler vum SIS-Controller
    Ausgabdaten:
    Zuel vun de Kontakter: 1NO+1NC
    Kontaktmaterial: Ag-Legierung
    Kontaktsécherungsschutz: 5A (Intern)
    Notzungskategorie: 5A/250V AC; 5A/24V DC
    Zäitdaten:
    Aschaltverzögerung: ≤ 30ms
    Verzögerter Ausschaltung: ≤30ms
    Erhuelungszäit: ≤ 30ms
    Kuerz Ënnerbriechung vun der Versuergung: 20ms

     

    Sécherheetszertifizéierung
    Leeschtungsniveau (PL) PLe entsprécht EN ISO 13849
    Sécherheetskategorie (Kat.) Kat.4 entsprécht EN ISO 13849
    Aufgabenzäit (TM) 20 Joer entsprécht EN ISO 13849
    Diagnosesch Ofdeckung (DC/DCavg) 99% entspriechen der EN ISO 13849
    Sécherheetsintegritéitsniveau (SIL) SIL3 entsprécht IEC 61508, IEC 62061
    Hardwarefehlertoleranz (HFT) 1 entsprécht IEC 61508, IEC 62061
    Sécher Ausfallfraktioun (SFF) 99% entspriechen IEC 61508, IEC 62061
    Wahrscheinlechkeet vun engem geféierleche Feeler (PFHd) 3.09E-10/h entsprécht IEC 61508, IEC 62061
    Stopkategorie 0 entsprécht der EN 60204-1
    10% duerchschnëttlech Zuel vu geféierleche Feelerzyklen vu Komponenten (B10d)
    DC13, Ue=24V D.h. 5A 2A 1A
    Zyklen 300.000 2.000.000 7.000.000
    AC15, Ue=230V D.h. 5A 2A 1A
    Zyklen 200.000 230.000 380.000

     

    Ëmweltcharakteristiken
    Elektromagnetesch Kompatibilitéit EN 60947, EN 61000-6-2, EN 61000-6-4
    Vibratiounsfrequenz 10Hz~55Hz
    Vibratiounsamplitude 0,35 mm
    Ëmgéigungstemperatur -20 ℃~+60 ℃
    Lagertemperatur -40 ℃~+85 ℃
    Relativ Loftfiichtegkeet 10% bis 90%
    Isolatiounseigenschaften
    Elektresch Distanz a Schleichdistanz entsprécht EN 60947-1
    Iwwerspannungsniveau III.
    Verschmotzungsniveau 2
    Schutzniveau IP20
    Isolatiounsstäerkt 1500V AC, 1 Minutt
    Nenn-Isolatiounsspannung 250V Wiesselstroum
    Nennimpulsspannung 6000V (1,2/50us)

     

    Extern Dimensiounen

    PH6004-1AR1B.png

    Funktionellt Blockdiagramm

    PH6004-1AR1B(1).png

    Typesch Uwendung

    PH6004-1AR1B(2).png

    Schaltplang

    (1) D'Instrumentverdrahtung benotzt e pluggbare Verbindungsterminal;
    (2) D'Querschnittsfläche vum mëllen Koffer vum Input-Säite-Drot muss méi grouss wéi 0,5 mm2 sinn, an d'Output-Säit muss méi grouss wéi 1 mm2 sinn;
    (3) Déi fräigeluecht Längt vum Drot ass ongeféier 8 mm, deen duerch M3-Schrauwen fixéiert ass;
    (4) D'Ausgangskontakter mussen ausreechend Sécherungsverbindunge bidden;
    (5) De Kupferleiter muss enger Ëmgéigungstemperatur vun op d'mannst 75 ℃ standhalen;
    (6) D'Schrauwen vun den Terminaler kënnen zu engem Feeler am Betrib, enger Iwwerhëtzung usw. féieren. Dofir sollt Dir se w.e.g. no dem spezifizéierten Dréimoment unzéien. D'Unzéihmoment vun der Terminalschrauf ass 0,5 Nm.

    Verkabelung.png

    Installatioun

    Sécherheetsrelaise sollten a Steierschränke mat engem Schutzniveau vun op d'mannst IP54 installéiert ginn.
    D'Sécherheetsrelais vun der Serie PH6005-1AR1B-F sinn all mat DIN35mm Führungsschinnen installéiert. D'Installatiounsschrëtt sinn wéi follegt.
    (1) Klemmt den ieweschten Enn vum Instrument op d'Führungsschinn;
    (2) Dréckt den ënneschten Enn vum Instrument an d'Führungsschinn.

    Installatioun.png

    Ofbau

    Setzt e Schrauber (Klingenbreet ≤ 6mm) an de Metallverriegelung um ënneschten Enn vum Instrumentenbrett an;
    Dréckt de Schrauber no uewen a dréckt de Metallverriegelung no ënnen;
    Zitt den Instrumentenbrett no uewen an aus der Führungsschinn eraus.

    Demontage.png

    Ënnerhalt

    (1) Kontrolléiert w.e.g. reegelméisseg, ob d'Sécherheetsfunktioun vum Sécherheetsrelais a guddem Zoustand ass, an ob et Zeeche gëtt, datt de Stroumkrees oder den Original manipuléiert oder ëmgaange gouf;
    (2) Halt Iech w.e.g. un déi relevant Sécherheetsbestëmmungen a schafft no den Instruktiounen an dësem Gebrauchsanweisung, soss kann et zu fatale Accidenter oder Verloscht vu Personal a Besëtz féieren;
    (3) D'Produkter goufen streng iwwerpréift a Qualitéitskontroll gemaach, ier se d'Fabréck verlooss hunn. Wann Dir feststellt, datt d'Produkter net richteg funktionéieren a Verdacht hutt, datt den internen Modul defekt ass, kontaktéiert w.e.g. den nächste Vertrieder oder kontaktéiert direkt d'Hotline fir techneschen Support.
    (4) Bannent sechs Joer nom Liwwerdatum ginn all Problemer mat der Produktqualitéit beim normale Gebrauch vu Pinghe gratis reparéiert.

     

    Opmierksamkeet

    Iwwerpréift w.e.g., ob d'Produktverpackung, de Modell vum Produktetikett an d'Spezifikatioune mam Kafvertrag iwwereneestëmmen;
    Liest dëst Handbuch virsiichteg ier Dir Sécherheetsrelais installéiert a benotzt;
    Wann Dir Froen hutt, kontaktéiert w.e.g. d'Technesch Support-Hotline zu Beijing Pinghe ënner 400 711 6763;
    De Sécherheetsrelais soll an engem Steierschrank mat op d'mannst dem Schutzniveau IP54 installéiert ginn;
    D'Instrument gëtt mat enger 24V-Stroumversuergung ugedriwwen, an d'Benotzung vun enger 220V-Wiesselstroumversuergung ass streng verbueden;