Sistem Tegangan 24V (SPD Aman Sacaro Batin)
Fitur
SPESIFIKASI
Data teknis | Duo kawat | Kawat tigo | ||
Jenis produk | PHL-S24-L2-Masal.5kA | PHL-S24-L2-Masal.10kA | PHL-S24-L3-Masal.5kA | PHL-S24-L3-Masal.10kA |
Arus debit nominal Dalam (8 / 20 μs) | 5kA | 10kA | 5kA | 10kA |
Arus debit maksimum (8 / 20μs) | 10kA | 20kA | 10kA | 20kA |
Arus lonjakan kilek pincang (10/350μs) | 0,5kA | 2kA | 0,5kA | 2kA |
Total arus lonjakan kilek (10/350μs) | 1kA | 4kA | 1,5kA | 6kA |
Tegangan operasi nan dinilai Un | 24V | 24V | ||
Tegangan operasi maksimum Uc . | 32V | 32V | ||
Arus operasi nominal IL . | 600mA | 600mA | ||
Tegangan palinduangan Naik (8 / 20μs) garih-ka-garih / garih ka tanah | 60V/600V | 60V/600V | ||
Tegangan perlindungan Naik (1KV/μs) jalur ka jalur/garis ka tanah | 60V/600V | 60V/600V | ||
Lebar pita (-0,5dB) | 10MHz | 10MHz | ||
Wakatu tanggapan | 1s | 1s | ||
Tahanan seri (satiok barih) | 1Ω | 1Ω | ||
Arus bocor | ||||
Tingkat palinduangan nan disadiokan dek kandang (sasuai jo IEC 60529) | IP 20 | IP 20 | ||
Bahan parumahan / Kelas tahan api (nan UL94) | PC/V0 | PC/V0 | ||
Standar uji | GB/T 18802,21 / IEC61643-21 | GB/T 18802,21 / IEC61643-21 | ||
Sertifikasi tahan malatuih | EX ia II C T4-T6 Ga | EX ia II C T4-T6 Ga | ||
Kisaran suhu karajo | -40~+80°C | -40~+80°C | ||
Gambar

Dimensi kasaluruahan

Gambar skematik