English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Kritt direkt en Devis
Leave Your Message
PHD-12HT-*11
Isoléiert Sécherheetsbarrièren fir d'Montage vun der H-Serie Backplane
Produktkategorien
Ausgewielte Produkter

PHD-12HT-*11

TC-Input/4~20mA-Output (konfiguréierbar)
H Serie Backplane Montage Isoléiert Sécherheetsbarrièren
1 Input 2 Outputs

    Iwwersiicht

    Den PHD-12HT-*11 konvertéiert e Gläichstroumsignal (TC) mat nidderegem Niveau vun engem Temperatursensor an engem geféierleche Beräich an e Stroumsignal vu 4~20mA fir d'Undriff vun enger Belaaschtung an engem séchere Beräich. Dëst Produkt huet eng agebaute Kaltendkompensatiounsfunktioun, kann intelligent konfiguréiert ginn, an den aktuellen Reechwäit vum Thermoelement kann iwwer d'Computersoftware agestallt ginn. Et huet eng Drotbrochalarmfunktioun an eng Alarmfunktioun fir ausserhalb vum Reechwäit.
    D'Produkt erfuerdert eng separat Stroumversuergung mat dräifacher Isolatioun fir Stroum, Input an Output.
    "*" weist den Typ vun der Thermoelement-Input un, de spezifesche Modell mam Code (kuckt d'Figur hei ënnendrënner)


    Tabelle vun engem Inputsignaltyp a Beräich

    Code

    Thermoelementmodell

    Miessberäich

    Minimalberäich

    Konversiounsgenauegkeet

    1

    K.

    -200~1370℃

    50℃

    0,5℃/ 0,1%

    2

    S

    -50~1760℃

    50℃

    1,5℃/ 0,1%

    3

    AN

    -140~1000℃

    50℃

    0,5℃/ 0,1%

    4

    J

    -160~1200℃

    500℃

    0,5℃/ 0,1%

    5

    B

    250~1800℃

    50℃

    1,5℃/ 0,1%

    6

    T

    -200~400℃

    500℃

    0,5℃/ 0,1%

    7

    R

    -50~1760℃

    50℃

    1,5℃/ 0,1%

    8

    N

    -200~1300℃

    500℃

    0,5℃/ 0,1%

     

     


    Haapt technesch Parameteren

     

    Zuel vun de Kanäl:

    een Input an zwee Outputs

    Stroumversuergung:

     

    Stroumversuergungsspannung:

    20~35V DC, Stroumverbrauch vun ongeféier 1,8W (24V DC, Ausgang 20mA)

    Stroumschutz:

    Réckwärtsschutz

    Geféierlech Säiteninput:

     

    Inputsignal:

    K-, S-, E-, J-, B-, T-, R-, N-Thermoelementsignaler (kuckt "Tabell iwwer Inputsignaltypen a Beräicher")

    Signalberäich:

    Entsprécht dem Miessberäich vum Thermoelement -10~100mV.

    Miessberäich:

    de Benotzer seng eege Konfiguratioun beim Bestellen z'entwéckelen, déi an der Endnummer oder aner Instruktiounen spezifizéiert ass

    Agebaute Kaltendkompensatioun:

    ±1℃ (Kompensatiounsberäich -20℃~+60℃)

    Sécherheetssäit Ausgang:

     

    Ausgangssignal:

    4~20mA

    Zulässlech Ausgangsbelaaschtungskapazitéit:

    0~500Ω (personaliséierbar)

    LED-Indikator:

    Gréng ⸺ Stroumindikator; L1 Luucht u fir Alarm fir niddreg Reechwäit; L2 Luucht u fir Alarm fir héich Reechwäit.

    Ausgangsgenauegkeet:

    Kuckt "Tabell iwwer den Typ an d'Beräich vum Inputsignal".

    Äntwertzäit:

    500ms bis 90% vum Endwäert

    Temperaturdrift:

    0,005%FS/°C

    Temperaturparameter:

    Betribstemperatur -20℃~+60℃; Lagertemperatur -40℃~+80℃

    Relativ Loftfiichtegkeet:

    10%~95%RH ouni Kondensatioun

    Isolatiounsstäerkt:

    intrinsesch sécher Enn an net intrinsesch sécher Enn (≥3000V AC/min); tëscht der Stroumversuergung an der net intrinsesch sécherer (≥1500V AC/min)

    Isolatiounswidderstand:

    ≥100MΩ (Input/Output/Stroumversuergung tëscht)

    Elektromagnetesch Kompatibilitéit:

    am Aklang mat IEC 61326-1 (GB/T 18268), IEC 61326-3-1

    Duerchschnëttlech Zäit bis zum Echec:

    100000 Stonnen

    Ufuerderunge fir den Drot:

    Querschnitt ≥ 0,5 mm2; Isolatiounsstäerkt ≥ 500 V

    Uwendbar Feldgeräter:

    Uwendbar Feldgeräter: K, S, E, J, B, T, R, N Thermoelementsensor

    Installatiounsplaz:

    an der sécherer Zon installéiert, kann mat den héchsten an Zonen 0, IIC, Zonen 20, IIIC geféierleche Beräicher vun der intrinsesch sécherer Instrumentatioun verbonne ginn

    Sécherheetszertifizéierung

     

    Zertifizéierungsorgan:

    Nationalt Zentrum fir d'Qualitéitsiwwerwaachung an d'Testung vun explosiounsgeschützten elektresche Produkter CQST

    Zertifizéierungsstandard:

    GB/T 3836.1-2021, GB/T 3836.4-2021

    Explosiounsséchert Symbol:

    [Exia Ga]ⅡC, [Exia Da]ⅢC

    Zertifizéiert Parameteren (tëscht den Terminalen 1-2):

    Um: 250V AC/DC, Uo=8,4V DC, Io=31mA,
    Po=65,1W, Co=4,8μF, Lo=20mH.


    PHD-12HT-X11



    Datei_eroflueden
    PHD-11TC-33A-23