English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Accipe Estimationem Statim
Leave Your Message
PHD-22TP-1313 / PHD-22TP-2323
Frequentia Ingressa
Categoriae Productorum
Producta Insignia

PHD-22TP-1313 / PHD-22TP-2323

Obiex securitatis isolatus ingressus signalis frequentiae

Duo ingressus, duo exitus

Frequentiae Signi Ingressus

Signum frequentiae 1: 1 Egressus

    Conspectus

    Signum frequentiae in claustra securitatis isolata immittitur, quae potest transmissionem 1: 1 signi frequentiae instrumenti animadvertere in periculosus aream ad aream tutam, et vim isolatam praebe copia (12V vel 24V) pro instrumento agro in periculosus regio.

    Hoc productum fontem potentiae independentem requirit, et fontem potentiae, Ingressus et egressus inter se separantur.

     

    VII

     

    Ingressus in regione periculosa
    Signum ingressus Frequentia ≤ 100kHz, amplitudo ≤ 12V, cyclus officii ≥ 20%, gradus altus ≥ 4V, gradus humilis ≤ 1V (PHD-22TP-1313) Frequentia ≤ 100kHz, amplitudo ≤ 24V, cyclus officii ≥ 20%, gradus altus ≥ 4V, gradus humilis ≤ 1V (PHD-22TP-2323)
    Tensio distributionis Tensio circuitus aperti ≤ 13V, tensio distributionis ≥ 8.5V cum 25mA onusta (PHD-22TP-1313)
    Tensio circuitus aperti ≤ 25V, tensio distributionis ≥ 16V cum 25mA onusta (PHD-22TP-2323)
    Exitus lateris securitatis:
    Signum egressus Frequentia 1: 1 egressus
    Ambitus signalis Signum humilis gradus ≤ 0.5V
    Signum altum gradum ≥ 10V (PHD-22TP-1313)
    Signum altum gradus ≥ 20V (PHD-22TP-2323)
    Impellere currentem ≤ 15mA, resistentia oneris ≥ 1k Ω
    Tensio alimentationis 20-35VDC
    Consumptio energiae Cum potentia 24VDC et egressu ad gradum 12V utitur
    ≤ 80mA (PHD-22TP-1313)
    ≤ 100mA (PHD-22TP-2323)
    Indicator LED Viridis: Indicator potentiae
    Tempus commutationis recipiendi et transmittendi ≥20ms
    Parametri temperaturae Temperatura operandi: -20℃~+60℃
    temperatura repositionis: -40℃ ~ +80℃
    Humiditas relativa 10%~95% RH nulla condensatio
    Robur dielectricum Inter latus intrinsece tutum et latus non intrinsece tutum (≥ 3000VAC/min);
    inter fontem potentiae et terminale non intrinsecus tutum (≥ 1500VAC/min)
    Resistentia insulationis ≥100MΩ (inter input/output/power supply)
    Compatibilitas electromagnetica Secundum IEC 61326-1 (GB/T 18268), IEC 61326-3-1
    MTBF 100000h
    Requisita filorum Sectio transversalis ≥ 0.5mm²; Robur insulationis ≥ 500V
    Instrumenta agrorum applicabilia Instrumenta mensurae frequentiae
    Locus institutionis In zona tuta installatum, instrumentis securitatis intrinsecae in locis periculosis usque ad Zonam 0, IIC, Zonam 20, et IIIC coniungi potest.
    Certificatio securitatis
    Signum explosionis probatum [Ex ia Ga]lIC [Ex ia Da]lllC
    Norma explosionis resistentis GB/T3836.1-2021  GB/T3836.4-2021
    PHD-22TP-1313
    Terminales 1-3, 4-6
    Um: 250V AC/DC Uo = 14.7V DC Io = 207mA
    Po = 0.76W Co = 0.5μF Lo = 0.56mH
    Terminales 2-3, 5-6 Um: 250V AC/DC Uo = 8V DC Io = 2.5mA
    Po = 5 mW Co = 5.9 µF Lo = 100 mH
    PHD-22TP-2323
    Terminales 1-3, 4-6 Um: 250V AC/DC Uo = 28V DC Io = 93mA
    Po = 0.65W Co = 0.05μF Lo = 2.4mH
    Terminales  2-3, 5-6 Um: 250V AC/DC Uo = 8V DC Io = 2.5mA
    Po = 5 mW Co = 5.9 µF Lo = 100 mH
    Corpus certificationis CQST (Centrum Nationale Sinense Supervisionis Qualitatis et Probationis pro Productis Electricis Explosionibus Protectis)



    PHD-22TP-1313 PHD-22TP-2323


    3CCNEX


    Deprime_fasciculum
    phd-22tp-1313-phd-22tp-2323