Latin
English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Accipe Estimationem Statim
Leave Your Message
PHD-11TF-28+
Ingressus Digitalis
Categoriae Productorum
Producta Insignia

PHD-11TF-28+

Typus Protectionis Contra Incrementum Input Digitale: Claustrum Securitatis Isolatum
PHD-11TF-28+ 1 introitus et 1 exitus

Input: Contactus commutationis/commutatores proximitatis
Exitus: Transistor

    Conspectus

    Claustrum securitatis separatum cum functione protectionis contra impetus tensionis a transistore ingressus et egressus commutatoris, quod signa ingressus a contactibus commutatoris vel commutatoribus proximitatis in locis periculosis ad zonam securitatis cum transistore egressus segregat et per claustrum securitatis transmittit. Detectio erroris lineae per LED in summo moduli fit. Commutator rotalis moduli ad ingressum et egressum in phase vel inversam gubernationem constituendam, necnon ad functionem indicationis alarmis detectionis erroris lineae activandam vel inactivandam adhibetur. Hoc productum fontem potentiae independentem requirit, cum fonte potentiae separato, terminalibus ingressus et egressus.

     

    1

     

    Ingressus in area periculosa
    Signum ingressus Contactus commutationis/commutatores proximitatis
    Tensio alimentationis sensoris Circa 8V
    Frequentiae input amplitudo ≤5kHz
    Proprietates input/output:
    Currentis ingressus in situ >2.1mA, egressus clausus est, indicans ON; Cum
    Commutatio moderationis inter phasim inversam et phasim normalem exitus ec Cum commutator rotarius K1 in positione "ON" est, egressus transistoris ec in phase inversa est. Cum commutator rotarius K1 in positione "OFF" est, egressus transistoris ec in phase normali est. Cum K2 in positione "ON" est, circuitus functionem alarmis indicationis LFD lucis rubrae eliget.
    Exitus
    Signum egressus Transistor et relais alarmis (ad libitum)
    Facultas impellendi Fluxus egressus ≤20mA (1.2kΩ), fluxus internus maximus 100mA, instructus praesidio contra fluxum brevis circuitus
    Proprietates tutelae contra impetus impetus:
    Currens nominalis exonerationis ln(8/20μs) 5kA
    Gradus tutelae tensionis Sursum (8/20μs): 60V (linea ad lineam)
    Gradus tutelae tensionis Sursum (8/20μs): 600V (linea ad terram)
    Secundum normas GB/T18802.21-2016 (aequivalens 1EC61643-21:2012)
    Parametri fundamentales
    Tensio alimentationis 20~35VDC
    Consumptio energiae
    Indicator LED Viridis: Indicator potentiae Flavus: Transistor egressus in statu normali operationis Ruber: Indicatio LFD, alarmum erroris lineae
    Parametri temperaturae Temperatura operandi: -20℃ ~ +60℃, Temperatura repositionis: -40℃ ~ +80℃
    Humiditas relativa 10%~95% RH nulla condensatio
    Robur insulationis
    Inter latus intrinsece tutum et latus non intrinsece tutum (≥3000VAC/min); inter fontem potentiae et latus non intrinsece tutum (≥1500VAC/min)
    Resistentia insulationis ≥100MΩ (inter input/output/power supply)
    Compatibilitas electromagnetica GB/T 18268 (IEC 61326-1)
    MTBF Octo milia horarum
    Requisita filorum Sectio transversalis ≥ 0.5mm²; Robur insulationis ≥ 500V
    Instrumenta agrorum applicabilia Instrumenta in agro, ut contactus sicci vel ingressus interruptorum proximitatis generis NAMUR, quae normae DIN19234 obtemperant.



    PHD-11TF-28+

    Nota: Fons potentiae ferriviae potentiae functio optionalis est.
    Usoribus modum fontis potentiae specificandum est cum ordinant.
    Vide quaeso annexum in pagina 89.
    1
    Detectio Vitiorum Linearum (LFD)
    Usoribus latus "ON" clavis in summo moduli deligere licet.
    ad functionem detectionis errorum activandam et ad indicandum alarmum per
    Lux LED rubra. Cursus ingressus in situ >7mA, alarmum circuitus brevis (SC);
    In situ fluxus ingressus
    Ingressus contactus functionem detectionis erroris requirit (ruptura fili, brevis circuitus)
    (in circuitu), resistor 22k Ω in utroque extremo paralleliter coniungendus est.
    commutatoris, et resistor 680 Ω in serie connectendus est (ut
    in schemate filorum electricorum pro contactu commutatoris II demonstratum).