English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Krij direkte offerte
Leave Your Message
PHD-12TF-277+
Digitale ynfier
Produktkategoryen
Featured Produkten

PHD-12TF-277+

Overspanningsbeskermingstype Digitale ynfier Isolearre feilichheidsbarriêre
PHD-12TF-277+ 1 ynfier en 2 útfier

Ynfier: Skeakelkontakten/nabijheidsschakelaars
Utfier: Relais

    Oersicht

    De isolearre feilichheidsbarriêre mei oerspanningsbeskermingsfunksje fan skeakelynputrelaisútgongen, dy't ynputsignalen isolearret en trochstjoert fan skeakelkontakten of tichtbyheidsskakelaars yn gefaarlike gebieten nei de feilichheidssône mei útfierrelais fia de feilichheidsbarriêre. Linefoutdeteksje wurdt berikt fia in aparte relaisútfier en wurdt werjûn op 'e boppeste LED fan' e module. De draaiknop fan 'e module wurdt brûkt om ynfier- en útfier yn-faze of omkearde kontrôle yn te stellen, lykas om de alarmindikaasjefunksje foar linefoutdeteksje yn of út te skeakeljen.
    Dit produkt fereasket in ûnôfhinklike stroomfoarsjenning, mei isolearre stroomfoarsjenning, ynfier- en útfierterminals.

     

    1

     

    Ynfier yn gefaarlik gebiet
    Ynfiersignaal Skeakelkontakten/nabijheidsschakelaars
    De oanfierspanning fan 'e sensor Sawat 8V
    Skeakelsnelheid
    Ynfier/útfier skaaimerken:
    Ynfierstroom op lokaasje >2.1mA, de útfier is sluten, wat oanjout op ON; As
    Utfier normaal "Iepen"/"Sletten" Kontaktkonverzjekontrôle
    As de draaiknop K1, K3 oan 'e "ON"-kant stiet, is de relaisútfier "Normaal sluten"
    As de draaiknop K1􀁡K3 oan de "ÚT"-kant stiet, is de relaisútfier "Normaal iepen"
    As de draaiknop K2􀁡K4 oan 'e "ON"-kant stiet, selektearret it circuit de LFD-alarmfunksje mei read ljocht.
    Útfier yn feilich gebiet
    Utfiersignaal Relais
    Rydkapasiteit 250VAC/2A, 30VDC/2A as ûnderwurpen oan wjerstânsbelastingen
    Reaksjetiid 20ms
    Funksjes fan oerspanningsbeskerming:
    Nominale ûntladingsstroom ln (8/20μs) 5 kA
    Spanningsbeskermingsnivo omheech (8/20μs): 60V (line nei line)
    Spanningsbeskermingsnivo omheech (8/20μs): 600V (line nei grûn)
    Neffens noarmen GB/T18802.21-2016 (lykweardich oan 1EC61643-21:2012)
    Basisparameters
    Oanfierspanning 20~35VDC
    Enerzjyferbrûk
    LED-yndikator Grien: Stroomindikator Giel: Utfierrelais yn normale wurkstatus Read: LFD-yndikaasje, linefoutalarm
    Temperatuerparameters Wurktemperatuer: -20℃ ~ +60℃, Opslachtemperatuer: -40℃ ~ +80℃
    Relative fochtigens 10% ~ 95% RH gjin kondensaasje
    Isolaasjesterkte
    Tusken yntrinsyk feilige kant en net-yntrinsyk feilige kant (≥3000VAC/min); tusken stroomfoarsjenning en net-yntrinsyk feilige kant (≥1500VAC/min)
    Isolaasjeresistinsje 100MΩ (500V DC) (tusken ynfier/útfier/stroomfoarsjenning)
    Elektromagnetyske kompatibiliteit GB/T 18268 (IEC 61326-1)
    MTBF 80000 oeren
    Triedeasken Dwersdoorsnede ≥ 0.5mm²; Isolaasjesterkte ≥ 500V
    Tapasselike fjildapparatuer Fjildapparatuer lykas droege kontakten of NAMUR-type tichtbyswitch-ynputen dy't foldogge oan de DIN19234-standert



    PHD-12TF-277+

    Opmerking: De stroomfoarsjenning fan 'e stroomrail is in opsjonele funksje. Brûkers moatte
    spesifisearje de stroomfoarsjenningsmodus by it bestellen.
    Sjoch de taheaksel op side 89.

    Linefoutdeteksje (LFD)
    Brûkers kinne de "ON" kant fan 'e skeakel oan' e boppekant fan 'e module selektearje
    om de foutdeteksjefunksje yn te skeakeljen en in alarm oan te jaan fia de
    read LED-ljocht. Ynfierstroom op lokaasje > 7mA, koartslutingsalarm (SC);
    Ynfierstroom op lokaasje
    kontaktynfier fereasket foutdeteksjefunksje (triedbreuk, koartsluting
    sirkwy), moat in 22k Ω-wjerstân oan beide úteinen parallel ferbûn wurde
    fan 'e skeakel, en in 680 Ω-wjerstân moat yn searje ferbûn wurde (lykas
    werjûn yn it bedradingsdiagram foar skeakelkontakt II).