English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Kry onmiddellike kwotasie
Leave Your Message
PHD-11HZ-*1
H-reeks agtervlakmontering geïsoleerde veiligheidsversperrings
Produkte Kategorieë
Aanbevole Produkte

PHD-11HZ-*1

RTD-inset/4~20mA-uitset (konfigureerbaar)
H-reeks agtervlakmontering geïsoleerde veiligheidsversperrings
1 invoer 1 uitvoer

    Oorsig

    Die PHD-11HZ-*1 skakel weerstandstemperatuurdetektor (RTD) seine in die gevaarlike area om na 4~20mA stroomseine vir die aandrywing van veilige area-laste. Intelligente konfigurasie is beskikbaar, en die werklike reikwydte van die RTD kan deur rekenaarsagteware ingestel word. Met gebreekte draadalarmfunksie en buite-reikwydte-alarmfunksie.
    Die produk benodig 'n aparte kragtoevoer met drievoudige isolasie vir krag, invoer en uitvoer.
    "*" dui die termokoppel-insettipe aan, die spesifieke model met die kode (sien die figuur hieronder)


    Invoerseintipes en meetbereik

    Kode

    RTD-model

    Meetbereik

    Minimum reikwydte

    Omskakelingsakkuraatheid

    1

    G53

    -50~150℃

    20℃

    0.2℃/0.1%

    2

    G50

    -50~150℃

    20℃

    0.2℃/0.1%

    4

    Pt100

    -200~850℃

    20℃

    0.2℃/0.1%

    6

    Pt1000

    -200~850℃

    20℃

    0.2℃/0.1%

    7

    Ni1000

    -60~250℃

    20℃

    0.2℃/0.1%


     

     


    Aantal kanale:

    een invoer en een uitvoer

    Kragtoevoer:

     

    Kragtoevoerspanning:

    20~35V GS, kragverbruik van ongeveer 1.2W (24V GS, uitset 20mA)

    Kragbeskerming:

    krag omgekeerde beskerming

    Gevaarlike sy-invoer:

     

    Invoersein:

    2-draads of 3-draads RTD-sein (sien "Insetseintipe en -bereiktabel")

    Seinbereik:

    Ooreenstemmend met die meetbereik van RTD's.

    Meetbereik:

    die gebruiker om hul eie konfigurasie te ontwikkel wanneer hulle bestel, soos gespesifiseer in die eindnommer of ander instruksies

    Veiligheidskant-uitvoer:

     

    Uitsetsein:

    4~20mA

    Toelaatbare Uitsetladingskapasiteit:

    0~500Ω (Aanpasbaar)

    LED-aanwyser:

    Groen ⸺Krag-aanwyser; L1-liggie aan vir lae-reikwydte-alarm; L2-liggie aan vir hoë-reikwydte-alarm.

    Uitset akkuraatheid:

    Sien "Invoersein tipe en bereik tabel".

    Reaksietyd:

    300ms tot 90% van finale waarde

    Temperatuurdrif:

    0.005%FS/°C

    Temperatuurparameters:

    bedryfstemperatuur -20℃~+60℃; bergingstemperatuur -40℃~+80℃

    Relatiewe lugvogtigheid:

    10%~95%RH sonder kondensasie

    Isolasiesterkte:

    intrinsiek veilige kant en nie-intrinsiek veilige kant (≥3000V AC/min); tussen kragtoevoer en nie-intrinsiek veilige (≥1500V AC/min)

    Isolasieweerstand:

    ≥100MΩ (inset/uitset/kragtoevoer tussen)

    Elektromagnetiese versoenbaarheid:

    in lyn met IEC 61326-1 (GB/T 18268), IEC 61326-3-1

    Gemiddelde tyd tot mislukking:

    100000 uur

    Draadvereistes:

    deursnee ≥ 0.5mm2; isolasiesterkte ≥ 500V

    Toepaslike veldtoestelle:

    2-draads of 3-draads OTO G53, Cu50, Pt100, Pt1000, Ni1000

    Installasieplek:

    geïnstalleer in die veilige sone, kan gekoppel word aan die hoogste gevaarlike liggings van die intrinsiek veilige instrumentasie in Sone 0, IIC, Sone 20, IIIC