- Terminal Board
- Makabukud a Safety Barriers
- Signal Isolators
- Surge Protective Devices
- Safety Relays
- Isolated Intelligent I/O Modules
- Intelligent Gateways
- Industrial Data Optical Transceivers
- Online Dew Point Analyzers
- Data Acquisition Modules
- HART data converter
PHL-T series
Balamu
Deng peka-tampok ilapin deng:
1. Atin yang failure window diagnosis function (optional)
2. 12.4mm ultra-thin, compatible keng dual-channel signal transmission, makatipid keng espasyu;
3. Matas a bandwidth ampo mababa ing insertion loss, masanting ya para kareng sablang uri ning signal;
Technical data
| Parameter | PHL-T5-L2-EX PHL-T5-L3-EX PHL-T5-L4-EX | PHL-T5-G2-EX PHL-T5-G4-EX | PHL-T24-L2-EX PHL-T24-L3-EX PHL-T24-L4-EX | PHL-T24-G2-EX PHL-T24-G4-EX |
| Rated operational voltage | 5VCD | 5VCD | 24VDC | 24VDC |
| Maximum operating voltage Uc | 6VDC | 6VDC | 32VDC | 32VDC |
| Rated operating current IL | 600mA | 600mA | 600mA | 600mA |
| kapamilatan ning pamaglaban | 1Ω/line | 1Ω/wire | 1Ω/wire | 1Ω/wire |
| Bandwidth (-0.5dB) | 10MHZ | 10MHZ | 10MHZ | 10MHZ |
| oras ning pakibat | 1ns | 1ns | 1ns | 1ns |
| Leakage current | ||||
| Nominal discharge current In (8 / 20μs) | 10kA/wire | 10kA/wire | 10kA/wire | 10kA/wire |
| Ing maximum discharge current Imax (8 / 20μs) | 20kA/wire | 20kA/wire | 20kA/wire | 20kA/wire |
| Lightning surge current limp (10 / 350μs) | 2.5kA/wire | 2.5kA/wire | 2.5kA/wire | 2.5kA/wire |
| Protection voltage Up line-to-line | 40V | 40V | 60V | 60V |
| Protection voltage Up line to ground | 600V | 40V | 600V | 60V |
| Temperature range | -40°C~+80°C |
| Relatibung humidity | 10e~95% |
| Panlual a sukad (kaba x lapad x katas) | 90.0mm×12.4mm×77.5mm |
| Koneksyun | Tornilyo wiring |
| Maximum cross-sectional area ning kawad | 2.5mm |
| Cross section area ning guide rail grounding wire | 4~6mm |
| Paralan ning pamag-install | DN35mm Rail |
Outline dimension diagram

Failure window diagnosis function

Sertipiku ning seguridad



(2) Ing terminal malyari yang ikonekta keng multi-strand copper wire a maki cross-sectional area a 0.2~2.5mm2 o single-strand copper wire a maki cross-sectional area a 0.2~4mm2 ;
(3)Ing kaba ning wire stripping mga 5-8mm ya, na makakandadu kareng tornilyu.

Ing PHL-T series universal model gagamitan ne ing DIN35mm guide rail installation method, at deng steps ilapin deng makatuki:
⑴I-clamp me ing babo nang metal keng lalam ning instrumentu keng DIN rail;
Itulak me ing metal a bage keng lalam ning instrumentu keng guide rail;
6Isuggest ing gamitan ing tansu o bakal a riles.

Disassembly

Ayusan
(1) Nung gagamit kang SPD, kailangan atin yang mapanalig a grounding;
(2) Bayu ya ma-electrify at ma-debug ing SDP, kailangan yang tignan pasibayu nung ustu ya ing koneksyun ning input ampo output terminals;
(3) Ding produktu dinalan lang mahigpit a pamagsuri at pamagkontrol king kalidad bayu la meko king pabrika. nung akit mu na ing obra abnormal ya at magduda ka na ing internal module atin yang depektu, pakisabi me ing pekamalapit a ahente o diretsu kang makipag ugnayan keng technical support hotline keng oras;
(4) Kilub ning metung a banua manibat keng petsa ning pamagdeliver, nanu mang problema keng kalidad ning produktu keng normal a pamangamit dapat yang ayusan ning Beijing Pinghe alang bayad.