- Terminal Board-ah hian a awm a
- Hriselna atana harsatna awmte
- Signal Isolators te pawh a awm
- Surge laka invenna hmanrua te
- Safety Relay te a awm bawk
- Intelligent I/O Module hrang hrang awmte
- Gateways fing tak tak te
- Industrial Data Optical Transceiver hmanga siam a ni
- Online hmanga Dew Point thlirletna
- Data lakkhawmna Modules te
- HART data converter a ni
01 a ni02 a ni03 a ni04 a ni05 a ni
PHD-11TN-11 / PHD-22TN-1111 hmanga siam a ni
A tlangpuiin
Flame leh smoke detector hmanga isolated safety barrier te hian signal a input a, hei hian hmun hlauhawma flame detector te tan isolation power a pe thei a ni. Flame detector hian hmun hlauhawm atang hian 0-40mA signal a siam a, hmun him lamah a thawn chhuak a, smoke alarm role a thawk a ni. He product hian output loop power supply a hmang a, loop power supply nei DCS/PLC system tan a tha hle.
He product hian independent power supply a mamawh lo va, input leh output terminal te pawh isolated a ni.
| Hriselna hmuna input | |
| Signal input a ni | 0~40mA a ni |
| Distribution voltage a ni | Uo≥Ui-(280+RL)I-6,Ui≤24V Uo≥18-(280+RL)l,Ui>24V a ni |
| Short circuit current a awm a | ≤65mA (24V hmanga power pek a nih chuan) |
| Safety lam atanga chhuak: | |
| A chhuahna signal a ni | 0~40mA a ni |
| Signal power supply a ni | 20-35VDC thleng a ni |
| LED hmanga entir a ni | Green: thiltihtheihna lantir |
| Transmission dik tak a ni | |
| Chhanna hun pek hun | 2ms chhunga final value 90% thleng |
| Temperature a inthlak danglam thin | 0.01%FS/°C a ni |
| Temperature parameter hrang hrangte | Hnathawh lumna: -20°C~+60°C |
| a dahna hmun:-40°C~+80°C | |
| Relative humidity a awm lo | 10%~95% RH ah chuan condensation a awm lo |
| Dielectric chakna a ni | Intrinsically safe side leh non-intrinsically safe side inkar (≥ 3000VAC/min); |
| power supply leh non-intrinsically safe terminal (≥ 1500VAC/min) inkar a ni. | |
| Insulation a do theih loh | ≥100MΩ (input/output/power supply inkar) a ni. |
| Electromagnetic nena inmil theihna | IEC 61326-1(GB/T 18268) ang chuan, IEC 61326-3-1 |
| MTBF | 100000h a ni |
| Wire mamawh a ni | Cross section ≥ 0.5mm2 a ni a; Insulation chakna ≥ 500V a ni |
| Field hmanrua hman tur | Meialh leh meikhu hriat theihna |
| Installation hmun a ni | Safe zone-a dah a nih chuan Zone 0, IIC, Zone 20, leh IIIC thlenga hmun hlauhawma intrinsic safety instrument-te nen a inzawm thei a ni |
| Intrinsically him tak certification pek a ni | |
| Explosion proof chhinchhiahna | [Ex ia Ga]lIC [Ex ia Da]lllC |
| Puak thei lo standard a ni | GB/T3836.1-2021 thleng a ni GB/T3836.4-2021 ah a awm a |
| Terminal5-6, 2-3 te a ni | Um: 250V AC/DC Uo=25.2V DC lo=93mA a ni |
| Po=586mW Co=0.083μF Lo=4.2mH a ni | |
| Certification siamtu pawl a ni | CQST(China National Quality Supervision leh Explosion Protected Electrical Products te enfiahna hmun) |

Note: PHD-11TN-11 hian input 2 leh output 2 part a huam lo


PHD-11TC-33A-23-ah a awm bawk