English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Kritt direkt en Devis
Leave Your Message
PHC-11TD-11+
Analog Ausgang
Produktkategorien
Ausgewielte Produkter

PHC-11TD-11+

Analog Ausgang isoléiert Sécherheetsbarrière mat Iwwerspannungsschutzfunktioun

Input an 1 Output

Input: 4~20mA (HART digitales Signal)
Ausgang: 4~20mA (HART-Digitalsignal)

    Iwwersiicht

    Déi isoléiert Sécherheetsbarriär mat analogem Ausgang a Spannungsschutzfunktioun kann déi isoléiert Iwwerdroung vu 4~20mA Signaler vun den Instrumenter am Sécherheetsberäich an de geféierleche Beräich realiséieren, de Ventilpositionéierer, den elektreschen/pneumatesche Konverter an aner Ausrüstung op der Plaz undreiwen, an déi bidirektional Iwwerdroung vun digitale HART Signaler mat Drotbrochalarmfunktioun ënnerstëtzen. Dëst Produkt brauch eng onofhängeg Stroumversuergung, an d'Stroumversuergung, den Input an den Output sinn isoléiert.

    Spezifikatiounen

    Gitt an engem sécheren Beräich an
    Inputsignal 4~20mA (HART-Digitalsignal)
    Ausgab am geféierleche Beräich
    Ausgangssignal 4~20 mA (HART-Digitalsignal)
    Belaaschtungswiderstand Beim Ausgang vun 20mA, 0~500 Ω (personaliséierbar)
    Nennenentladungsstroum ln(8/20μs) 5 kA ze
    Spannungsschutzniveau erop (8/20μs): 60V (Linn zu Linn)
    Spannungsschutzniveau erop (8/20μs): 600V (Linn bis Mass)
    No de Standarden GB/T18802.21-2016 (gläichwäerteg mat 1EC61643-21:2012)
    Basisparameter
    Versuergungsspannung 20~35VDC
    Stroumverbrauch ≤50mA (24V Stroumversuergung, 20mA Ausgang)
    LED-Indikator Gréng: Stroumindikator
    Ausgangsgenauegkeet 0,1%FS (Typesche Wäert: 0,05%FS)
    Reaktiounszäit 2ms fir 90% vum Endwäert z'erreechen
    Temperaturdrift 0,005% FS/℃
    Temperaturparameter Aarbechtstemperatur: -20℃ ~ +60℃,
    Lagertemperatur: -40℃ ~ +80℃
    Relativ Loftfiichtegkeet 10%~95% RH keng Kondensatioun
    Isolatiounsstäerkt Zwëschen der intrinsesch sécherer Säit an der net intrinsesch sécherer Säit (≥3000VAC/min); tëscht der Stroumversuergung an der net intrinsesch sécherer Säit (≥1500VAC/min)
    Isolatiounswiderstand ≥100MΩ (tëscht Input/Output/Stroumversuergung)
    Elektromagnetesch Kompatibilitéit Geméiss IEC 61326-1 (GB/T 18268), IEC 61326-3-1
    MTBF 100000 Stonnen
    Ufuerderunge fir den Drot Querschnitt ≥ 0,5 mm²; Isolatiounsstäerkt ≥ 500 V
    Uwendbar Feldausrüstung Ventillokalisatioun, elektresch/pneumatesch Konverter
    Installatiounsplaz Installéiert an enger sécherer Zon, kann et un intrinsesch Sécherheetsinstrumenter a geféierleche Beräicher bis zu der Zon 0, IIC, Zon 20 an IIIC ugeschloss ginn.
    Zertifizéierung fir intrinsesch sécher
    Explosiounssécher Markéierung [Ex ia Ga]lIC [Ex ia Da]llc
    Explosiounsséchere Standard GB/T3836.1-2021 GB/T3836.4-2021
    Terminalen 3-4 Um: 250V AC/DC Uo=28V DC lo=93mA
    Po=0,65W Co=0,083μF Lo=4,2mH
    Zertifizéierungsorgan CQST (China National Quality Supervision and Test Centre for Explosiounsgeschützte Elektroprodukter)
    Shanghai Testzentrum fir Blitzschutzprodukter

     

    Dimensioun

    PHC-11TD-11+.jpg

    Schematesch Zeechnungen

    PHC-11TD-11+(1).jpg

     

    Bemierkung: D'Power Rail-Funktioun ass eng optional Funktioun, an d'Benotzer mussen spezifizéierend'Method vun der Stroumversuergung beim Bestellung
    D'Auswiel vun de Stroumleitungsschinneverbinder kann op Säit 89 vum "Annex" verweisen.

    Datei_eroflueden
    PHC-11TD-11+