English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Accipe Estimationem Statim
Leave Your Message
PHG-11TF-27+
Isolatores Signorum Typi Protectionis Contra Impetus Incrementales
Categoriae Productorum
Producta Insignia

PHG-11TF-27+

Typus Protectionis Contra Incrementum Impetus: Isolatores Signi Ingressus Digitalis
PHG-11TF-27+ 1 introitus et 1 exitus

Input: Contactus commutationis/commutatores proximitatis
Exitus: Relay

    Conspectus

    Separator signi input relais output commutatoris protectionis contra impetus signum input contactus commutatoris vel commutatoris proximitatis in output relais per segregationem convertit.
    Detectio erroris lineae per separatum relevatorium emittitur et lumine LED in summo moduli ostenditur. Commutator moduli ad eligendam phasim canalis et utrum functio detectionis erroris lineae requiratur utrum.
    Hoc productum separatim potentiam accipiendum est, et fontem potentiae, terminales input et output separati sint.

    Specificationes

    Inputum
    Signum ingressus Contactus commutationis/commutatores proximitatis
    Tensio alimentationis sensoris Circa 8V
    Frequentia commutationis
    Proprietates input/output:
    Currentis ingressus in situ >2.1mA, egressus clausus est, indicans ON;
    Cum
    Egressus normaliter "Apertus"/"Clausus" Cum commutator rotarius K1 in latere "ON" est, egressus relé "Normaliter apertus" est.
    Imperium conversionis contactus Cum commutator rotarius K1 in latere "OFF" est, egressus relé "Normaliter clausus" est.
    Cum commutator rotarius K2 in latere "ON" est, circuitus functionem alarmi LFD lucis rubrae indicantis eligit.
    Exitus
    Signum egressus Relay et relay alarmi (ad libitum)
    Capacitas impulsoris 250VAC/2A, 30VDC/2A cum oneribus resistivis subiectum est
    Tempus responsionis XXms
    Proprietates tutelae contra impetus impetus:
    Currens nominalis exonerationis ln(8/20μs) 5kA
    Gradus tutelae tensionis Sursum (8/20μs): 60V (linea ad lineam)
    Gradus tutelae tensionis Sursum (8/20μs): 600V (linea ad terram)
    Secundum normas GB/T18802.21-2016 (aequivalens 1EC61643-21:2012)
    Parametri fundamentales
    Tensio alimentationis 20~35VDC
    Consumptio energiae
    Indicator LED Viridis: Indicator potentiae
    Flavus: Relais emissarius in statu normali operandi
    Ruber: Indicatio LFD, alarmum defectus lineae
    Parametri temperaturae Temperatura operandi: -20℃ ~ +60℃,
    Temperatura repositionis: -40℃ ~ +80℃
    Humiditas relativa 10%~95% RH nulla condensatio
    Robur insulationis ≥2000VAC/min (inter input/output/power supply)
    Resistentia insulationis 100MΩ (500V DC) (inter ingressum/exitum/alimentationem potentiae)
    Compatibilitas electromagnetica GB/T 18268 (IEC 61326-1)
    MTBF Octo milia horarum
    Requisita filorum Sectio transversalis ≥ 0.5mm2; Robur insulationis ≥ 500V
    Instrumenta agrorum applicabilia Instrumenta in agro, ut contactus sicci vel ingressus interruptorum proximitatis generis NAMUR, quae normae DIN19234 obtemperant.

    Dimensio

    PHG-11TF-27+.jpg

    Connexiones filorum

    PHG-11TF-27+(1).jpg

    Nota:
    1. Alimentatio electrica ferriviae electricae functio facultativa est. Usoribus modum alimentationis electricae specificandum est cum ordinem faciunt. Vide annexum in pagina 89.

    Detectio Errorum Linearum

    Usoribus latus "ON" commutatoris in summo moduli deligere licet ut functio detectionis errorum activetur et alarmum per lucernam LED rubram indicetur. Fluxus ingressus in situ > 7mA, alarmum circuitus brevis (SC); Fluxus ingressus in situ