English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Entuk Penawaran Langsung
Leave Your Message
Piranti Pelindung Lonjakan (SPD Arus Searah)
Piranti Pelindung Lonjakan Daya
Kategori Produk
Produk Unggulan

Piranti Pelindung Lonjakan (SPD Arus Searah)

Piranti Pelindung Lonjakan (SPD Arus Searah)

    Cakupan Aplikasi

    SPD cocok kanggo kabeh jinis sistem distribusi voltase rendah kanthi voltase jaringan ing ngisor 1000 volt lan frekuensi 50/60HZ, kayata pos lan telekomunikasi, rel sepur, sistem keuangan, lapangan minyak, bangunan dhuwur, omah lan gedung kantor. Kanggo nglindhungi peralatan listrik (kayata komputer, instrumen lan peralatan, peralatan rumah tangga, lsp.) saka pangguna listrik iki saka sambaran bledhek, overvoltage transien lan kerusakan overvoltage lonjakan liyane. Njamin keamanan peralatan lan pribadi. Iki minangka piranti proteksi overvoltage sing ideal.

    Struktur utama lan prinsip kerja

    Ing sistem telung fase papat kabel, pelindung disambungake antarane kabel telung fase lan kabel netral menyang kabel ground (deleng gambar ing ngisor iki). Ing kahanan normal, pelindung ana ing kahanan Levin, lan nalika jaringan listrik kena tegangan surge amarga bledhek utawa alesan liyane. Pelindung bakal cepet diuripake sajrone wektu nanodetik, ngenalake tegangan surge menyang bumi, saengga nglindhungi peralatan listrik ing jaringan listrik. Nalika tegangan surge ngliwati pelindung lan ilang, pelindung bali menyang kahanan resistensi dhuwur maneh. Supaya ora mengaruhi operasi normal jaringan listrik.

    Fitur

    1. Nggunakake kabel internal, kabeh struktur kompak lan instalasi lan grounding trep.
    2. Reaksi kecepatan tinggi, wektu operasi kurang saka 25ns
    3. Tampilan status kerjane jelas, ijo (normal) lan abang (kesalahan).
    4. Fungsi tambahan bisa ditambahake, kayata alarm akustik-optik (B) lan kontak komunikasi jarak jauh kesalahan (X).
     
    Kondisi kerja normal SPD
     
    1. Dhuwure ora ngluwihi 2000m:
    2. Suhu udara sekitar: kisaran normal: -5℃+40℃, kisaran sing luwih dawa: -40℃+70℃;
    3. Kelembapan relatif udara: 30%--90% ing suhu njero ruangan;
    4. Kemiringan ing bidang vertikal ora kena ngluwihi 5.
    5. Ing ngendi ora ana goncangan lan getaran sing jelas.
    6. Ora ana bebaya bledosan ing medium kasebut, lan ora ana gas lan bledug (kalebu bledug konduktif) sing cukup kanggo ngrusak logam lan ngrusak insulasi ing medium kasebut.
     
    Parameter teknis
     
    Model Tegangan operasi terus-menerus maksimum Uc Tegangan proteksi Munggah (Mudhun Mlebu) Arus debit nominal Ing (8 / 20μs)kA Arus debit maksimum (8 / 20μs)kA
    PHL-TA-24 24V 500V 20kA 40kA
    PHL-TA-110 110V 700V 20kA 40kA
    PHL-TA-220 220V 800V 20kA 40kA
    PHL-TA-1000 1000V 2.6 kV 20kA 40kA
    Wektu respon t (ns)
    Arus bocor μA
    Cara instalasi Rel DIN 35mm
    Bahan omah Peningkatan tahan api PA66
    Dimensi (mm) Kekandelan modul 18mm: 90 * 54 * 68 (3P) : 90 * 36 * 68 (2P)

     

    Model

    Komunikasi.png

    Instalasi lan dimensi njaba

    Komunikasi (1).png

    Seri pelindung lonjakan arus iki dipasang nganggo gauge pandhuan instalasi topi ndhuwur standar, lan poin-poin ing ngisor iki kudu digatekake sajrone instalasi.
    1. Kabel sing disambungake yaiku 2.5-16mm² kabel fleksibel sing cocog kanggo kecepatan aliran kasebut; Kabel atos 2.5-25mm²
    2. Sekring utawa saklar udara kudu disambungake seri ing sisih ngarep pelindung.
    3. Pateni sumber daya nalika instalasi.
     
    Pangopènan
     
    1. Sawise pelindung dipasang kaya sing dibutuhake, bisa kanthi otomatis nglindhungi jaringan listrik tanpa penyesuaian.
    2. Nalika tandha ijo, tegese modul kasebut bisa digunakake kanthi normal; nalika tandha abang, tegese modul saiki wis rusak lan kudu diganti kanthi tepat wektu.
    3. Priksa modul saben nem sasi lan ganti sawise rusak.
    4. Priksa manawa saklar udara utawa sekring sing disambungake seri ing kabel kasebut normal.
     
    Cakupan layanan garansi
     
    1. Iki digawe ing pabrik asli
    2. Karusakan kasebut disebabake dening masalah kualitas saka pabrikan.
     
    Kahanan ing ngisor iki ora kalebu ing surat perintahlan
     
    1. Kerusakan sing disebabake manungsa
    2. Karusakan sing disebabake dening bencana alam kayata banjir lan kahanan sing ora bisa diendhani;
    3. Karusakan sing disebabake amarga ora dipasang lan digunakake miturut pandhuan sing bener ing katrangan produk.
    4. Kerusakan sing disebabake dening aplikasi produk sing ngluwihi spesifikasi teknis