Guarani
English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Ojehupyty Cotización Instantánea
Leave Your Message
Dispositivos Protectores sobre sobretensiones de CA rehegua
Dispositivos Protectores sobre sobretensiones de Potencia rehegua
Productos Categorías rehegua
Umi mba’e ojehechaukáva

Dispositivos Protectores sobre sobretensiones de CA rehegua

Dispositivos Protectores sobre sobretensiones de CA rehegua

    Ámbito de Aplicación rehegua

    SPD iporã opaichagua sistema de distribución baja tensión orekóva tensión red 1000 voltios guýpe ha frecuencia 50/60HZ, ha'eháicha correo ha telecomunicaciones, ferrocarril, sistema financiero, campo petrolero, edificio yvate, óga ha edificio de oficinas. Oñangareko haguã umi aparato eléctrico (ha'eháicha computadora, instrumento ha equipo, electrodoméstico, hamba'e) ko'ã usuario energía reheguáva ani haguã oity rayo, sobretensión transitoria ha ambue daño sobretensión sobretensión. Oasegura tembiporu ha seguridad personal. Ha’e peteĩ dispositivo ideal protección sobretensión rehegua.

    Estructura principal ha principio de trabajo

    Pe sistema irundy alambre mbohapy fase rehegua, oñembojoaju umi protector umi alambre mbohapy fase rehegua ha petet alambre neutro alambre yvy rehegua ndive (ehecha ta anga iguýpe). Circunstancia normal-pe, protector oime estado Levin-pe, ha oî jave red eléctrica sobretensión de oleada rayo térã ambue mba'ére. Pe protector pya’e oñemboguéta nanosegundos-pe, omoingévo sobretensión de oleada yvype, upéicha oñeñangareko umi equipo eléctrico oĩva red eléctrica-pe. Pe sobretensión sobretensión rehegua ohasávo pe protector rupi ha okañy, pe protector oho jey pe estado de alta resistencia-pe. Ani haguã oityvyro funcionamiento normal red eléctrica-pe.

    AC SPD.png rehegua

    Heseguáva

    1.Oipurúvo cableado interno, estructura pukukue ha'e compacto ha instalación ha tierra ha'e conveniente.
    2.Reacción de alta velocidad, tiempo de operación mbovyvéva 25ns-gui
    3.Pe estado de trabajo jehechauka ojehecha porã, hovy (normal) ha pytã (falla).
    4.Ikatu oñembojoapy función adicional, ha'eháicha alarma acústo-óptica (B) ha contacto comunicación remoto falla (X).
     
    Condiciones normales de trabajo SPD rehegua
     
    1.Pe altitud ndohasái 2000m:
    2.Ambient aire temperatura: rango normal: -5 ° C + 40 ° C, rango extendido:-40 ° C + 70 ° C;
    3.Aire pariente reheguahumva'ekuety:30%--90% temperatura óga ryepýpe;
    4.Pe inclinación oíva plano verticalpe ndohasái va era 5.
    5.Ndaipórihápe ojehechakuaáva tembýpe ha vibración impacto.
    6.Ndaipóri peligro de explosión medio-pe, ha ndaipóri gas ha yvytimbo (oikehápe polvo conductor) suficiente okorosiona haguã metal ha ombyai aislamiento pe medio-pe.
     
     
    Parámetro técnico rehegua
    Techapyrãramo Tensión máxima de funcionamiento continuo rehegua Uc Tensión protección rehegua Yvate (Bajo En) . Corriente de descarga nominal En (8 / 20μs)kA Corriente máxima descarga rehegua (8 / 20μs)kA
    160 rehegua 440V rehegua 3.0KV rehegua 100 rehegua 160 rehegua
    100 rehegua 440V rehegua 2,8KV rehegua 60 rehegua 100 rehegua
    80 rehegua 440V rehegua 2,5KV rehegua 40 rehegua 80 rehegua
    60 rehegua 440V rehegua 2.3KV rehegua 30 rehegua 60 rehegua
    40 rehegua 440V rehegua 2.0KV rehegua 20 rehegua 40 rehegua
    20 rehegua 440V rehegua 1,5KV rehegua 10. Ñe’ẽpoty ha purahéi 20 rehegua
    Wf tolerancia energía rehegua A(2ms) . 200 rehegua
    Ñembohovái aravo t (ns) .
    Ie Corriente de fugas μA rehegua
    Método de instalación rehegua 35mmDIN Riel rehegua
    Material de vivienda rehegua Retardante tatatĩ rehegua oñembohapéva PA66
    Dimensiones rehegua Módulo ijyvatekue:18mm90X54X68 (3P), 90X72X68 (4P) 90X36X68 (2P)
    Módulo ijyvatekue:27mm 90X81X68 (3P), 90Xl08X68 ​​(4P), 90X54X68 (2P)
    Módulo ijyvatekue:36mm 90X I 08X68 ​​(3P), 90X I 44X68 (4P), 90X72X68 (2P)

    Techapyrãramo

    Protector de sobretensiones de potencia modular rehegua
    AC SPD (3) .png rehegua
    Diagrama conexión cableado rehegua
     
    AC SPD (5) .png rehegua
    Instalación ha dimensión okapegua
    AC SPD (4) .png rehegua
     
    Ko serie de protectores de sobretensiones oñemohenda calibrador guía instalación estándar sombrero superior rupive, ha ojesarekova'erã ko'ã punto rehe instalación jave.
    1、Pe alambre connecte ha'e 2. 5-16mm2 alambre flexible ohóva upe caudal-pe guarã; Alambre hatã 2,5-25mm2
    2、Peteĩ fusible térã peteĩ interruptor de aire oñembojoaju vaʼerã en serie pe protector rembeʼýpe.
    3、Oñembogue pe fuente de alimentación instalación aja.
     
    Ñangareko
    1、Oñemoĩ rire pe protector oñeikotevẽháicha, ikatu oñangareko ijeheguiete pe red eléctrica rehe oñemoambue’ỹre.
    2、Pe signo hovy jave, he’ise omba’apoha normalmente; pe signo pytã jave, heꞌise pe módulo koꞌag̃agua ofalla hague ha oñemyengoviavaꞌerãha itiempoitépe.
    3、Ehecha pe módulo cada seis meses ha emyengovia itiempope ofalla rire.
    4、Akóinte ojesareko interruptor de aire térã fusible oñembojoajúva en serie línea-pe ha'épa normal.
     
    Alcance servicio rehegua garantía rehegua
    1、It' s ojejapo fábrica original-pe
    2、Pe daño ojejapo pe problema de calidad orekóva pe fabricante.
     
    Ko’ã condición ndoguerekói cubierto pe garantía-pe
    1、Yvypóra ojapova’ekue mba’e vai
    2、Perjuicio ojapóva desastre natural ha'eháicha inundación ha fuerza mayor;
    3、Pe mba'e vai ojejapóva noñeinstalái ha ndojeporúigui umi instrucción hekopete oĩva producto descripción-pe.
    4、Pe perjuicio ojapóva aplicación umi producto ohasáva especificaciones técnicas