Galician
English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Obter un orzamento instantáneo
Leave Your Message
Relé de seguridade intelixente PH6001-1A
Relés de seguridade do sistema SIS
Categorías de produtos
Produtos destacados

Relé de seguridade intelixente PH6001-1A

O PH6001-1A é un módulo de control de relé de seguridade axeitado para a conversión de illamento de sinal DI/DO no sistema SIS. Ten un contacto normalmente aberto (NA) e o terminal reservado é conveniente para unha proba de proba rápida fóra de liña. O circuíto interno adopta tecnoloxía a proba de fallos, tecnoloxía de tripla redundancia e tecnoloxía de protección de soldadura por contacto.

    Datos técnicos

    Datos técnicos
    Características da fonte de alimentación
    Fonte de alimentación 24 V CC
    Consumo actual ≤35 mA (24 V CC)
    Rango de tensión 16V~35V CC
    Características de entrada
    corrente de entrada ≤ 35 mA (24 V CC)
    Resistencia do fío ≤ 15 Ω
    Dispositivo de entrada Sinais DI/DO do controlador SIS
    Características de saída
    Número de contactos 1Nº
    Material de contacto AgSnO2
    Protección con fusible Excontact 5A (Interno)
    capacidade de contacto 5 A/250 V CA; 5 A/24 V CC
    vida útil mecánica máis de 10⁷ veces
    Características do tempo
    Retardo de activación ≤ 30 ms
    Retardo na desactivación de enerxía ≤ 30 ms
    Tempo de recuperación ≤ 30 ms
    Interrupción curta do subministro 20 ms

     

    certificación de seguridade
    Nivel de integridade de seguridade (SIL) SIL3 cumpre coa norma IEC 61508
    Tolerancia a fallos de hardware (HFT) 0 cumpre coa norma IEC 61508
    Fracción de fallo seguro (SFF) 99 % de conformidade coa norma IEC 61508
    Probabilidade de fallo perigoso (PFHd) 1,00E-09/h segundo a norma IEC 61508
    PararCategoría 0 cumpre coa norma EN 60204-1
    10 % do número medio de ciclos de fallo perigoso de compoñentes (B10d)
    Tensión nominal 24 V CC, L/R = 7 ms É dicir, 2A 1A 0,5A
    Ciclos 180.000 300.000 400.000
    Tensión nominal 230 V CA, cos φ = 0,4 É dicir, 2A 1A 0,5A
    Ciclos 500.000 580.000 600.000

     

    Características ambientais
    Compatibilidade electromagnética conforme a EN 60947, EN 61000-6-2, EN 61000-6-4
    Frecuencia de vibración 10 Hz~55 Hz
    Amplitude da vibración 0,35 mm
    Temperatura ambiente -20 ℃~+60 ℃
    Temperatura de almacenamento -40 ℃~+85 ℃
    Humidade relativa 10% a 90%
    Altitude ≤ 2000 m

     

    Características de illamento
    Distancia de separación e de fuga eléctrica conforme á norma EN 60947-1
    Nivel de sobretensión III
    nivel de contaminación 2
    Nivel de protección IP20
    Resistencia do illamento 1500 V CA, 1 minuto
    Tensión de illamento nominal 250 V CA
    Tensión impulsiva nominal 6000 V (1,2/50 µs)

     

    Dimensións externas

    1d65

     

    Diagrama de bloques

    2b1r

     

    Diagrama de cableado

    3wsd

    (1) A fiação do instrumento adopta un terminal de conexión enchufable;
    (2) A área da sección transversal de cobre brando do fío do lado de entrada debe ser superior a 0,5 mm2 e o lado de saída debe ser superior a 1 mm2;
    (3) A lonxitude exposta do cable é duns 8 mm, que está fixada con parafusos M3;
    (4) Os contactos de saída deben proporcionar suficientes conexións de protección por fusible;
    (5) O condutor de cobre debe soportar unha temperatura ambiente de polo menos 75 ℃;
    (6) Os parafusos dos terminais poden provocar un mal funcionamento, quecemento, etc. Polo tanto, aperteos segundo o par especificado. Par de aperto dos parafusos dos terminais de 0,5 Nm.

    cableadorps

    Instalación

    Os relés de seguridade deben instalarse en armarios de control cun nivel de protección mínimo IP54.
    Os relés de seguridade da serie PH6001-1A instálanse todos con carrís guía DIN35 mm. Os pasos de instalación son os seguintes
    (1) Fixe o extremo superior do instrumento no carril guía;
    (2) Empurre o extremo inferior do instrumento para introducilo no carril guía.

    instalardxn

    Desmantelamento

    Introduza un destornillador (ancho da folla ≤ 6 mm) no pestillo metálico do extremo inferior do panel de instrumentos;
    Empurre o destornillador cara arriba e faga panca no pestillo metálico cara abaixo;
    Tire do panel de instrumentos cara arriba e sáqueo do carril guía.

    desaxuda

    Atención

    Verifique se a embalaxe do produto, o modelo da etiqueta do produto e as especificacións son coherentes co contrato de compra;
    Antes de instalar e usar relés de seguridade, lea atentamente este manual;
    Se tes algunha dúbida, ponte en contacto coa liña directa de asistencia técnica de Beijing Pinghe no teléfono 400 711 6763;
    O relé de seguridade debe instalarse nun armario de control cun nivel de protección mínimo IP54;
    O instrumento funciona cunha fonte de alimentación de 24 V e o uso dunha fonte de alimentación de CA de 220 V está estritamente prohibido;

     

    Mantemento

    (1) Comprobe regularmente se a función de seguridade do relé de seguridade está en bo estado e se hai sinais de que o circuíto ou o orixinal estean manipulados ou puenteados;
    (2) Siga as normas de seguridade pertinentes e opere segundo as instrucións deste manual de instrucións; se non, podería provocar accidentes mortais ou perdas de persoal e bens;
    (3) Os produtos foron sometidos a unha rigorosa inspección e control de calidade antes de saír da fábrica. Se detecta que os produtos non funcionan correctamente e sospeita que o módulo interno está defectuoso, póñase en contacto co representante máis próximo ou directamente coa liña de asistencia técnica.
    (4) Dentro dos seis anos seguintes á data de entrega, Pinghe reparará de balde todos os problemas de calidade do produto durante o uso normal.