English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Få et øjeblikkeligt tilbud
Leave Your Message
PHD-12TZ-461
Temperaturindgang
Produktkategorier
Udvalgte produkter

PHD-12TZ-461

To- eller tre-tråds RTD Pt100-signal

1 udgang med RTD 1:1 signal, en udgang med 4~20mA signal

1 indgang 2 udgange

    Oversigt

    Termistorindgangsisoleringssikkerhedsbarrieren kan konvertere Pt100-signalerne fra to- og tretrådede termistorer (RTD'er) i eksplosionsfarlige områder til én udgang med 1:1 RTD-signal og én udgang med 4~20mA signal til sikkerhedszonen. Den kan konfigureres intelligent, og det faktiske område for den termiske modstand kan indstilles via computersoftware.

    Dette produkt kræver uafhængig strømforsyning med isolerede strømforsyninger samt indgangs- og udgangsterminaler.

     

    2

     

    Specifikationer
    Indgang i farligt område  
    Indgangssignal To- eller tretråds RTD Pt100-signal
    Måleområde -200℃-850℃
    Sikkerhedssideudgang:
    Udgangssignal RTD Pt100-signal og 4~20mA-signal
    Lastkapacitet Belastningskapacitet 0-500 Ω (kan tilpasses)
    Forsyningsspænding 20-35 VDC
    Strømforbrug ≤76mA (ved 24VDC strømforsyning, udgang 20mA)
    LED-indikator Grøn: Strømindikator
    Outputnøjagtighed 0,1% FS
    Temperaturdrift 0,1% FS/10 ℃
    Temperaturparametre Arbejdstemperatur: -20℃~+60℃, opbevaringstemperatur: -40℃~+80℃
    Relativ luftfugtighed 10%~95% RF ingen kondensering
    Dielektrisk styrke Mellem den egensikre side og den ikke-egensikre side (≥ 3000 VAC/min);
    mellem strømforsyning og ikke-egensikker terminal (≥ 1500VAC/min)
    Isolationsmodstand ≥100MΩ (mellem input/output/strømforsyning)
    Elektromagnetisk kompatibilitet I henhold til IEC 61326-1 (GB/T 18268), IEC 61326-3-1
    MTBF 100000 timer
    Krav til ledninger Tværsnit ≥ 0,5 mm2; Isolationsstyrke ≥ 500 V
    Anvendeligt feltudstyr To- eller tretråds modstandstemperaturføler Pt100
    Installationssted Installeret i en sikker zone kan den tilsluttes til intrinsiske sikkerhedsinstrumenter i farlige områder op til Zone 0, IIC, Zone 20 og IIIC.
    Sikkerhedscertificering
    Eksplosionssikkert mærke [Ex ia Ga]lIC [Ex ia Da]llc
    Eksplosionssikker standard GB/T3836.1-2021  GB/T3836.4-2021
    Terminaler 4-6, 5-6 Um: 250V AC/DC Uo=8,4V DC lo=31mA
    Po=65,1 mW Co=4,8 μF Lo=20 mH
    Certificeringsorgan CQST (Kinas nationale kvalitetsovervågnings- og testcenter for eksplosionsbeskyttede elektriske produkter)



    phd-12tz-461

    Bemærk: 1. Strømskinnefunktionen er en valgfri funktion, og brugerne skal specificere strømforsyningsmetoden ved bestilling

    Udvælgelsen af ​​strømskinneforbindelser kan ses på side 89 i "Bilaget".

    2. Når der indlæses en tretråds RTD, er det nødvendigt at sikre, at de tre ledningerne er så lange som muligt

    3. Ved indlæsning af en to-tråds RTD skal sikkerhedsbarrierens terminaler 6 og 5 være kortsluttet