- Papan Terminal
- Halangan Kasalametan anu Terisolasi
- Isolator Sinyal
- Alat Pelindung Lonjakan
- Relay Kasalametan
- Modul I/O Cerdas Terisolasi
- Gerbang Calakan
- Transceiver Optik Data Industri
- Alat Analisis Titik Embun Online
- Modul Akuisisi Data
- Konverter data HART
Sistem Tegangan PHL-S24-L2-Ex 24V (SPD Aman Sacara Intrinsik)
Spésifikasi
Spésifikasi
Data téknis | Dua kawat | Tilu kawat | ||
Jenis produk | PHL-S24-L2-Ex.5kA | PHL-S24-L2-Ex.10kA | PHL-S24-L3-Ex.5kA | PHL-S24-L3-Ex.10kA |
Arus debit nominal In (8 / 20μs) | 5kA | 10kA | 5kA | 10kA |
Arus debit maksimum (8 / 20μs) | 10kA | 20kA | 10kA | 20kA |
Arus lonjakan kilat limp (10 / 350μs) | 0,5kA | 2kA | 0,5kA | 2kA |
Total arus lonjakan kilat (10 / 350μs) | 1kA | 4kA | 1,5kA | 6kA |
Tegangan operasi anu dipeunteun Un | 24V | 24V | ||
Tegangan operasi maksimum Uc | 32V | 32V | ||
Arus operasi nominal IL | 600mA | 600mA | ||
Tegangan panyalindungan Naék (8 / 20μs) line-to-line / line to ground | 60V / 600V | 60V / 600V | ||
Tegangan panyalindungan Naék (1KV / μs) jalur ka jalur / jalur ka taneuh | 60V / 600V | 60V / 600V | ||
Lebar pita (-0.5dB) | 10MHz | 10MHz | ||
Waktu réspon | 1ns | 1ns | ||
Résistansi séri (per baris) | 1Ω | 1Ω | ||
Arus bocor | ||||
Tingkat panyalindungan anu disayogikeun ku kandang (saluyu sareng IEC 60529) | IP 20 | IP 20 | ||
Bahan wadah / Kelas tahan seuneu (UL94) | PC/V0 | PC/V0 | ||
Standar tés | GB/T 18802.21 / IEC61643-21 | GB/T 18802.21 / IEC61643-21 | ||
Sertifikasi tahan ledakan | EX ia II C T4-T6 Ga | EX ia II C T4-T6 Ga | ||
Rentang suhu kerja | -40~+80℃ | -40~+80℃ | ||
Diagram

Diménsi sakabéhna

Diagram skematis