- Guddiga Terminalka
- Caqabadaha Badbaadada ee Go'doonsan
- Kala-goysyada Calaamadaha
- Qalabka Ilaalinta Kororka
- Gudbinta Badbaadada
- Modules-yada I/O ee Caqliga leh ee Go'doonsan
- Albaabada Caqliga leh
- Xogta Warshadaha ee Gudbiyaasha Indhaha
- Falanqeeyayaasha Dhibcaha Dew ee Khadka Tooska ah
- Qaybaha Helitaanka Xogta
- Beddelaha xogta HART
010203
PHD-11TP-13
Dulmar Guud
Calaamadda soo noqnoqoshada waxaa la geliyaa caqabadda badbaadada ee go'doonsan, taas oo xaqiijin karta gudbinta 1: 1 ee calaamadda soo noqnoqoshada ee qalabka ee aagga khatarta ah una gudbisa aagga badbaadada leh, waxayna siin kartaa korontada go'doonsan (12V ama 24V) qalabka goobta ee aagga khatarta ah. Badeecadani waxay u baahan tahay koronto madax-bannaan, korontada, gelinta iyo wax-soo-saarkana waa la kala fogeeyaa.
| Danab bixinta | 20~35VDC, Isticmaalka Awoodda: Marka lagu shaqeeyo 24VDC iyo wax soo saarka heerka 12V ≤ 50mA (PHD-11TP-13) |
| Danab qaybinta | Danabka wareegga furan ≤13V, danab la bixiyay >8.5V marka culaysku yahay 25mA |
| Calaamadda gelinta | Soo noqnoqoshada ≤100KHz, baaxadda ≤12V, wareegga shaqada ≥20%, heer sare ≥4V, heer hoose ≤1V |
| Calaamadda soo baxaysa | Soo-saarid soo noqnoqota 1:1, heer sare ≥10V, heer hoose ≤0.5V, hadda wadista ≤15mA, iska caabbinta culayska ≥1KΩ |
| Tirada kanaalada soo gelinta iyo soo saarista | 1 gelin 1 wax soo saar |
| Qalabka goobta ee khuseeya | Qalabka cabbiraadda soo noqnoqoshada |
| Xuduudaha heerkulka | Heerkulka Shaqada: -20℃~+60℃, heerkulka kaydinta: -40℃~+80℃ |
| Qoyaan qaraabo ah | 10% ~ 95% RH ma jiro uumi-bax |
| Xoogga Dielectric | Inta u dhaxaysa dhinaca gudaha ee badbaadada leh iyo dhinaca aan gudaha ahayn ee badbaadada leh (≥ 3000VAC/daqiiqo); inta u dhaxaysa korontada iyo terminalka aan gudaha ahayn ee badbaadada leh (≥ 1500VAC/daqiiqo) |
| Iska caabinta dahaarka | ≥100MΩ (inta u dhaxaysa gelinta/soo-saarka/korontada) |
| Iswaafajinta korantada | Sida waafaqsan IEC 61326-1(GB/T 18268), IEC 61326-3-1 |
| Calaamadda qaraxa u adkeysan karta | [Ex ia Ga] IIC [Ex ia Da] ⅢC |
| Hay'adda Shahaadada | CQST (Xarunta Kormeerka Tayada Qaranka ee Shiinaha iyo Tijaabada Badeecadaha Korontada ee la Ilaaliyo Qaraxyada) |
| Terminalada1-2 | Um: 250V AC/DC Uo = 14.7V DC Io = 207mA Po=0.76W Co=0.5μF Lo=0.56mH |
| Terminalada 3-4 | Um: 250V AC/DC Uo=8V DC Io=2.5mA Po=5mW Co=5.9µF Lo=100mH |
| Shuruudaha goobta rakibidda | Iyada oo lagu rakibay aag ammaan ah, waxaa lagu xidhi karaa qalabka badbaadada gudaha ee meelaha khatarta ah ilaa Aagga 0, IIC, Aagga 20, iyo IIC. |
| MTBF | Qiyaastii 100000h |

Fiiro gaar ah: Shaqada tareenka korontada waa shaqo ikhtiyaari ah, isticmaalayaashuna waxay u baahan yihiin inay qeexaan
habka korontada marka la dalbanayo
Xulashada isku xirayaasha tareenka korontada waxay tixraaci kartaa bogga 89 ee "Lifaaqa"



PHD-11TC-33A-23

PHD-11TP-13