English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Pridobite takojšnjo ponudbo
Leave Your Message
PHL-TA-100/385/2P PHL-TA-100/385/3P PHL-TA-100/385/4P
Naprave za zaščito pred prenapetostjo
Kategorije izdelkov
Izbrani izdelki

PHL-TA-100/385/2P PHL-TA-100/385/3P PHL-TA-100/385/4P

Prenapetostni prenapetostni regulator (SPD) za izmenični tok (100 kA)

PHL-TA-100/385/2P

PHL-TA-100/385/3P

PHL-TA-100/385/4P

    Pregled izdelka
    Z uporabo trifazne prenapetostne zaščite druge stopnje in uporabo metode zaščite faznega in ozemljenega toka (PEN) v skupnem načinu je primerna za namestitev v območju LPZ1 in na stičišču LPZ2.

    Glavne značilnosti
    1. Funkcija samozaklepanja modula za preprečevanje izgube zaščite zaradi ohlapnih površin; 2. Funkcija »lahkega pritiska« modula 2 omogoča enostavno vstavljanje in odstranjevanje modulov za enostavno zamenjavo, 3 predhodno priključena podnožja za enostavno ožičenje.

    Tehnični parametri

     

     

     

     

     

     

     

     

     

    Nazivna delovna napetost Un

    230/400 V AC

    230/400 V AC

    230/400 V AC

    Največja obratovalna napetost Uc

    275 V AC

    385 V AC

    440 V AC

    275 V AC

    385 V AC

    440 V AC

    275 V AC

    385 V AC

    440 V AC

    Zaščitna napetost Up (In pod)

    Navzgor

    Navzgor

    Do

    Navzgor

    Navzgor

    Do

    Navzgor

    Navzgor

    Do

    Nazivni praznilni tok In (8/20 μs)

    60 kA

    60 kA

    60 kA

    Največji praznilni tok lmax (8/20 μs)

    100 kA

    100 kA

    100 kA

    Površina prečnega prereza priključne žice

    Fleksibilna žica 1,5 mm²–25 mm²

    Fleksibilna žica 1,5 mm²–25 mm²

    Fleksibilna žica 1,5 mm²–25 mm²

    Odzivni čas

    Stopnja zaščite ohišja (v skladu z IEC60529)

    IP20

    IP20

    IP20

    Material ohišja/stopnja vnetljivosti

    UL94-V0

    UL94-V0

    UL94-V0

    Preskusni standard

    GB/T 18802.11/IEC 61643-11

    GB/T 18802.11/IEC 61643-11

    GB/T 18802.11/IEC 61643-11

    Uporabni elektroenergetski sistem

    Enofazna dvožična

    Trifazni štirižični (TN-C sistem)
    Trifazni trižični (IT sistem)

    Trifazni petžilni (TN-S sistem)

    Funkcija indikatorja staranja

    Da (kar pomeni, da se je okno spremenilo iz zelene v rdečo)

    Da (kar pomeni, da se je okno spremenilo iz zelene v rdečo)

    Da (kar pomeni, da se je okno spremenilo iz zelene v rdečo)

    Izbira varovalke ali odklopnika (A)

    100, 125

    100, 125

    100, 125

    Funkcija termičnega ločevanja staranja

    Da

    Da

    Da

    Funkcija telesignalizacije

    Neobvezno

    Neobvezno

    Neobvezno

    Komunikacija RS485

    Neobvezno

    Neobvezno

    Neobvezno

    Delovno temperaturno območje

    -40°C~+80°C

    -40°C~+80°C

    -40°C~+80°C

    Način namestitve

    35 mm DIN letev

    35 mm DIN letev

    35 mm DIN letev


    DiagramPHL-TA-100 385 2P PHL-TA-100 385 3P PHL-TA-100 385 4P

    Diagram dimenzij orisaPHL-TA-100 385 2P PHL-TA-100 385 3P PHL-TA-100 385 4P3

    Povezava

    PHL-TA-100 385 2P PHL-TA-100 385 3P PHL-TA-100 385 4P2