- Terminal Board-ah hian a awm a
- Hriselna atana harsatna awmte
- Signal Isolators te pawh a awm
- Surge laka invenna hmanrua te
- Safety Relay te a awm bawk
- Intelligent I/O Module hrang hrang awmte
- Gateways fing tak tak te
- Industrial Data Optical Transceiver hmanga siam a ni
- Online hmanga Dew Point thlirletna
- Data lakkhawmna Modules te
- HART data converter a ni
PHD-22TD-2121 hmanga siam a ni
A tlangpuiin
Analog input isolated safety barrier hian hmun hlauhawma wire transmitter pahnih - leh pathum tan isolated power supply a pe a ni. Transmitter emaw current source atanga 4~20mA signal siam chu hmun hlauhawm atang chuan safe area output ah a kal a, chu chuan safe area ah load chu a khalh chhuak thin. Wire transmitter pahnih - pathum emaw current source signal emaw tan chuan he safety barrier hian 4~20mA signal-a superimposed Hart digital signal bidirectional communication a support a, wire breakage alarm function a nei bawk. He product hian independent power supply a mamawh a, power supply, input leh output terminal hrang hrang a awm bawk.
| Supply voltage a awm | 20 ~ 35V DC, Power hman zat: ≤130mA(24V power supply, 20mA output) |
| Transmitter sem chhuahna voltage a ni | Open circuit voltage chu ≤28V a ni a, circuit 20mA a nih chuan output voltage chu ≥15.5V a ni |
| Signal input a ni | wire pahnih emaw wire thum emaw hmanga transmitter emaw current source signal (HART) emaw hmangin . |
| A chhuahna signal a ni | 4~20mA (HART) a ni. |
| Output load theihna phalsak a ni | 0~500Ω(a duh angin a siam theih) |
| Output dik tak a ni | 0.1%FS a ni( 10) a ni.Typical value te chu a ni:0.05%FS a ni- . |
| Temperature a inthlak danglam thin | 0.005%FS/°C a ni |
| Input leh output channel awm zat | 2 input 2 output a ni |
| Field hmanrua hman tur | 2-wire, 3-wire transmitter leh current source signal, he product hi ABB, Fisher, Rosemount, Honeywell, bakah 3351, EJA, SIEMENS tan pawh a tha hle leh thil dang lakluh technology hmanga siam te a ni. |
| Temperature parameter hrang hrangte | Hnathawh lumna: -20°C~+60°C, dahna hmun:-40°C~+80°C |
| Relative humidity a awm lo | 10%~95% RH ah chuan condensation a awm lo |
| Insulation chakna a ni | Intrinsically safe side leh non-intrinsically safe side (≥3000VAC/min) inkar; power supply leh non-intrinsically safe side (≥1500VAC/min) inkar a ni. |
| Insulation a do theih loh | ≥100MΩ (input/output/power supply inkar) a ni. |
| Dimension hrang hrang | A thuk zawng 17.5mm* a zau zawng 108mm* a san zawng 118mm |
| Electromagnetic nena inmil theihna | IEC 61326-1(GB/T 18268) ang chuan, IEC 61326-3-1 |
| Puak thei lo chhinchhiahna | [Ex ia Ga] IIC [Ex ia Da] IIIC |
| Functional safety certification pek a ni | SIL3 chu IEC 61508 standard angin a ni |
| Certification Body a ni | CQST(China National Quality Supervision leh Explosion Protected Electrical Products te enfiahna hmun) |
| Terminal 2-3、2-1 ah a awm | A rilru a buai em em a, a rilru a hah em em bawk a. 28V DC Io=93mA |
| Terminal 1-3、4-6 ah a awm | Um:250V AC/DC Uo=7.2V DC Io=--- a ni a, a man pawh a to hle. |
| Installation site-a thil tulte | Safe zone-a dah a nih chuan a connect theih hmun hlauhawma intrinsic safety instruments te hman a ni Zone 0, IIC, Zone 20, leh IIIC thlengin a ni |
| MTBF | ≤100000h a ni |