Lombard
English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Ottien una preventiva istantanea
Leave Your Message
PHD-11TZ-*1
Entrata de la temperadüra
Categurì de prudott
Prodott in evidenza

PHD-11TZ-*1

Barriera de sicureza isulada de ingress RTD

1 ingress 1 uscita

Entrada del segnal RTD a dü o a tri fili / uscita de 4 ~ 20 mA (configurabil)

 

 

    Panoramica

    La barriera de sicureza de isulament de ingress RTD pœu cunvertir i segnai de dü o tri termistor de fil (RTD) en sit periculus en segnai de curent de 4-20mA e purtàl in de la zòna de sicureza. Pœu vèss configurà en mod intelijent e la gamma real de la resistenza termich pœu vèss stabilida travers de un software per urdinaduur. El g’ha i funziun de allarm de rottura di fil e de allarm fœura portata.

    Chestu prudut g’ha bisogn de un’alimentaziun indipendent, cun di morset de alimentaziun, de input e de output isulà.
    “*” rapresenta el tip de input del termistor e el mudel specifich l’è rapresentà de un codes (varda “Tip de segnal d’input e Tabela de interval” per i detai).

    Tip de segnai d’ingress e interval de misuraziun

    Codex

    Mudel RTD

    Interval de misuraziun

    Interval minim

    Precisiun de la cunversiun

    1

    G53

    -50~150°C

    20°C

    0,2°C/0,1%

    2

    Cu50

    -50~150°C

    20°C

    0,2°C/0,1%

    4

    Pt100

    -200~850°C

    20°C

    0,2°C/0,1%

    6

    1000 pez

    -200~850°C

    20°C

    0,2°C/0,1%

    7

    1000

    -60~250°C

    20°C

    0,2°C/0,1%

    Esempi: quand che l’ingress l’è 2 ingress cun coppia K, l’interval de temperadüra l’è de 0~1200°C, 2 uscit 4~20mA, alimentaziun 20~35VDC, alura el mudel duvaria vèss PHD-22TT-1111 (0~1200°C).

    L’interval de misuraziun pœu vèss impostà sul interval specificà de 0~1200°C cunt un urdinaduur.

    * Alimentaziun del terminal del bus, vardà l’appendice per i detai.

     

     

    Input in zona pericolosa  
    Segnal d'entrada Dü fil o tri segnai de termistor a fil (varda “Tabela del tip e interval del segnal d’ingress” per i detai)
    Discunnession de ingress El “allarm bas” predefinì pœu vèss mudificà en “allarm volt” travers del software de configuraziun
    Interval del segnal Interval de misuraziun curispundent de la resistenza termich
    Interval de misuraziun I utent fan la propria configuraziun quand urdenan e la indican al numer de coda o en olter mod.
    Uscita lateral de sicureza:  
    Segnal de uscita 4~20mA
    Capacità de carich de uscita 0~500Ω (personalizabil)
    Tip de uscita de tensiun facultatif, resistenza al carich RL ≥ 330kΩ
    Indicatur LED Verd: indicatur de alimentaziun
    Luce gialla de allarme a bassa portata accesa, luce rossa de allarme a volta portata accesa
    Precisiun de output Per piasé, fa riferiment a la “Tabela del tip e interval del segnal d’input” per i detai
    Temp de rispòsta Raggiungiment del 90% del valur final en 300 ms
    Deriva de la temperadüra 0,005%FS/°C
    Parametri de la temperadüra Temperadura de lavuraziun: -20°C~+60°C, temperadüra de cunservaziun:-40°C~+80°C
    Umidità relativa 10% ~ 95% RH senza cundensaziun
    Resistenza dieletrica Intra el lat intrinsecament sicür e el lat minga intrinsecament sicür (≥ 3000VAC/min);
    intra l’alimentaziun e el morset minga intrinsecament sicür (≥ 1500 VAC/min)
    Resistenza a l'isolament ≥100MΩ (intra ingress/uscita/alimentaziun)
    Cumpatibilità eletromagnetich Segond la CPI 61326-1 (GB/T 18268), la CPI 61326-3-1
    MTBF 100000 h
    Requisiti del fil Seziun trasversal ≥ 0,5mm2; Resistenza a l'isolament ≥ 500V
    Attrezzatur sul camp aplicabil Termistor a dü fil o a tri fil
    G53, Cu50, Pt100, Pt1000, Ni1000
    Lugar de instalaziun Instalà en una zòna sicüra, pœu vèss culegà a strüment de sicüreza intrinsech en sit periculus fin a la zòna 0, IIC, zòna 20 e IIIC
    Certificaziun intrinsecament sicüra  
    Certificaziun de sicureza funziunal SIL3 segond i norm IEC 61508
    Marca a prova de esplosion [Es ia Ga]lIC [Es ia Da]lllC
    Norma a prova de esplosion GB/T3836.1-2021  GB/T3836,4-2021
    Morsetti 3-2、4-2 Um:250V CA/CC Uo=8,4V lo CC=31mA
    Po=65,1 mW Co=4,8 μF Lo=20 mH
    Organism de certificaziun CQST (Centro naziunal de la supervisiun e de test de la qualità de la Cina per i prudott eletrich prutegiü di esplusiun)



    PHD-11TZ-X1 PHD-12TZ-X11

    Nota: 1. PHD-11TZ - * 1 non include la parte di uscita 2

    2. La funziun de la binaria de alimentaziun l’è una funziun facultatif e i utent g’han de specificar el metud de alimentaziun quand se fa un urden

    La seleziun di cunnetur de binari de alimentaziun pœu riferiss a la pagina 89 del “Annes”

    3. Quand se mett un RTD a tri fil, l’è necessari assicuràs che i tri i fil sun de istess luungheza pusibel

    4. Quand se mett un RTD a dü fil, i morsett 4 e 2 de la barriera de sicureza g’han de vèss curt circuit


    Certificat a prova de esplusiun de la seri PHD-TZ CZ_pagina-0001

    Scaricà_file
    PHD-11TZ-*1
    Scaricà_file
    PHD-11TZ-X1