English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Obter un orzamento instantáneo
Leave Your Message
PHD-22HF-2727
Barreiras de seguridade illadas para montaxe en placa posterior da serie H
Categorías de produtos
Produtos destacados

PHD-22HF-2727

Contacto de interruptorou entrada de interruptores de proximidade (NAMUR)/ saída de relé

 2 entradas 2 saídas

Barreiras de seguridade illadas para montaxe en placa posterior da serie H

    Visión xeral

    Barreiras de seguridade illadas para montaxe en placa posterior da serie H no lado da detección: PHD-22HF-2727, entrada e saída dixitais, entrada dual e saídas duales.
    A barreira illada pode converter o interruptor de proximidade e a entrada de contacto na zona perigosa no sinal de contacto do relé e transmitilo á zona segura.
    O relé de saída está equipado cun interruptor de selección para a situación "ON/OFF". Ademais, hai unha indicación de alarma de curtocircuíto ou circuíto aberto no sinal de entrada; o circuíto proporciona alimentación ao sensor de entrada.
    Este produto precisa dunha fonte de alimentación independente.
    O indicador de estado do sinal está configurado en vermello e amarelo para indicar o estado de funcionamento do relé de saída; cando se trata de alarmas, a luz é vermella e, durante o funcionamento normal, a luz é amarela.

     

     

    Tensión de subministración 20~35 V CC, consumo de enerxía
    Sinal de entrada

    Contacto de interruptor ou interruptores de proximidade (NAMUR)

    Tensión de alimentación do sensor no sitio 8V
    Características da entrada de sinal Corrente de entrada in situ: >2,1 mA, indicación it ON; Corrente de entrada in situ:
    Saída en zona segura Tempo de resposta: 20 ms, capacidade de accionamento: 250 V CA/2 A, 30 V CC/2 A baixo carga resistiva

    Saída normalmente "Aberta"/"Pechada"
    Control de conversión de contacto

    Cando o interruptor de disco K1, K3 está no lado "ON", a saída do relé está en "OFF"
    Cando o interruptor de disco K1, K3 está no lado "OFF", a saída do relé está en "ON"
    Cando o interruptor de dial K2, K4 está no lado "ON", o circuíto selecciona a función de alarma LFD con luz vermella indicadora.
    LFD Corrente de entrada in situ > 7 mA, alarma de curtocircuíto (SC), corrente de entrada in situ
    Para a entrada de contacto do interruptor, cando se require a función de detección de desconexión, débese conectar unha resistencia de 22 kΩ en paralelo en ambos os extremos do interruptor (consulte o contacto do interruptor II no diagrama de cableado seguinte)
    Número de entradas e saídas 2 entradas 2 saídas
    Equipos de campo aplicables Contacto seco ou interruptor de proximidade NAMUR segundo a norma DIN 19234
    Parámetro de temperatura Temperatura de traballo: -20 ℃ ~ +60 ℃, temperatura de almacenamento: -40 ℃ ~ +80 ℃
    Humidade relativa 10 %~95 % de HR sen condensación
    Rixidez dieléctrica Entre o lado intrinsecamente seguro e o lado non intrinsecamente seguro (≥3000 V CA/min); entre a fonte de alimentación e o terminal non intrinsecamente seguro (≥1500 V CA/min)
    Resistencia de illamento ≥100 MΩ (entre entrada/saída/fonte de alimentación)
    Dimensións Grosor 15,8 mm * ancho 104,8 mm * alto 116,1 mm
    Compatibilidade electromagnética Segundo a norma IEC 61326-1 (GB/T 18268), IEC 61326-3-1
    Marca a proba de explosións [Exia Ga]IIC, [Exia Da]IIIC
    Estándar de certificación GB/T 3836.1-2021, GB/T 3836.4-2021
    organismo de certificación CQST (Centro Nacional de Supervisión e Probas de Calidade de Produtos Eléctricos con Protección contra Explosións da China)
    Parámetros certificados (entre os terminais 1-2, 4-5)
    Um: 250 V CA/CC, Uo = 10,5 V CC, Io = 14 mA,
    Po=37 mW, Co=2,4 μF, Lo=165 mH.
    Requisitos do lugar de instalación

    Instalado nunha zona segura, pódese conectar a instrumentos de seguridade intrínseca en áreas perigosas ata a Zona 0, IIC, Zona 20 e IIIC

    MTBF ≤100000 h



    3

    Detección de fallos de liña (LFD)

    A detección de fallos de liña (LFD) é un interruptor seleccionable polo usuario na parte superior do módulo e indícase mediante un LED. Se se detecta un fallo de liña, o relé de fallo de liña péchase e o relé de saída do canal desconéctase. Alarma de curtocircuíto (SC) para corrente de entrada de campo >7mA; alarma de circuíto aberto (LB) para corrente de entrada de campo